background image

MASTER CONTROL PANEL

SCREWDRIVER

COUNTERTOP

WELLSLOK

GASKET

WARMER FLANGE

4 7/8

(124)

5

(127)

3 1/8

(79)

28 1/2

(724)

29 1/2

(749)

4 1/8
(105)

5 7/8

(149)

9 3/4
(248)

6 1/4
(159)

26 7/8

(683)

30 5/8

(778)

29 1/2
(749)

25 3/4

(654)

12 AWG Cu

90°C

CONTROL PANEL WITH
FLEXIBLE CONDUIT

1 INCH NPT DRAIN
WITH BALL VALVE

DROP-IN BAIN MARIE

INSTALLATION INSTRUCTIONS

TO PLUMB:

1. A drain with valve is supplied on all units. Location of the

valve handle is at the discretion of the fabricator (see drawing).

2. Connect 1" drain connection to a suitable drain line.

TO WIRE:

1. Final connection is accomplished by bringing proper power

supply leads (see 'WIRING REQUIREMENTS' label) through

conduit knockout to wire leads supplied within the Master

Control Panel. Check nameplates for voltage and phase.

NOTES:

BAIN MARIE STYLE HEATED TANKS ARE DESIGNED FOR WET
OPERATION ONLY.

THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH
APPLICABLE FEDERAL, STATE OR LOCAL PLUMBING AND
ELECTRICAL CODES.

302964-1  REV (-)

INSTALLATION INSTRUCTIONS

STYLE HEATED TANK

MODEL HT-227

WELLS/BLOOMFIELD * VERDI, NV

ELECTRICAL

CUTOUT DETAILS

PRODUCT DIMENSIONS

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. Required installation clearances:

Wooden and Metal Installation: DO NOT install closer than

4 1/8 inches to front wall, 1 inch to back and side walls,

and 10 3/4 inches to surface below the unit.

2. Unit shall be accessible for servicing from the bottom.

3. If storage is to be used underneath the unit, it is

recommended that a baffle be placed 12 inches below

the unit to avoid contact with elevated temperatures.

TO FABRICATE:

1. Lay out "cutout" dimensions on countertop and front

apron.

2. Lay out and fabricate control panel holes in counter

apron using the control box as a template.

3. Cut out holes 

TO INSTALL:

IMPORTANT - DO NOT disconnect lead wires from the

Master Control Panel when making installation.

1. Tilt and pass Control Panel and electrical box through

the countertop cutout, then through the apron cutout.

Lower modular section into countertop cutout and

position.

RECOMMENDATION: Before final seating of modular section

to countertop, apply a bead of silicone adhesive/sealant

to the underside of gasket supplied on the mounting

flange.

2. From underneath, insert screwdriver into slots in

Wellslock frame and twist ears outward (clockwise) as

required to secure flange tightly to countertop.

3. Mount Control Box to apron cutout as shown in drawing.

4. Mount Control Panel onto electrical box using the

screws supplied.

CLEARANCES

BACK

SIDE

BOTTOM

FRONT

(25)

1

1

(25)

(273)

10 3/4

(105)

4 1/8

MINIMUM CLEARANCE REQUIRED

FROM UNIT TO THE NEAREST SURFACE

90°C

12 AWG Cu

SINGLE

SINGLE

13.8

11.9

3300

2500

208

240

HT-227

HT-227

RATING

GAUGE

FIELD

TEMP.

WIRING

PHASE

AMPS

WATTS

VOLTS

MODEL

INCHES

(MM)

Reviews: