NOTE: DRILL SCREW
CLEARANCE HOLES
IN ASSEMBLY
SEAL HOLES AND
FASTENERS WITH
SILICONE SEALANT
NO.8X5/8 LONG
STAINLESS STEEL PAN
HEAD SCREW. LOCK
WASHER & NUT
COUNTER-TOP
DETAIL 'A'
SEALANT
CLEARANCES
BACK
SIDE
BOTTOM
FRONT
(25)
1
1
(25)
(171)
6 3/4
(105)
4 1/8
SUGGESTED CLEARANCES FROM UNIT
TO THE NEAREST SURFACE
TO FABRICATE AND INSTALL:
1. Lay out cutout dimensions on countertop and apron.
2. Cut and/or drill holes as required in countertop and apron.
3. Turn down flange with square corners (maximum 1/2 inch).
4. To install, position warmer underneath so that turn down is
positioned onto embossed shoulders of warmer. Drill as
required.
5. Remove warmer and apply a bead of silicone sealant to
shoulder area. Remount and secure warmer to fixture with
stainless steel screws (see Detail "A" above).
6. Mount control to apron.
7. Connect supply connection wiring to thermostat. Check
nameplate for correct voltage.
SEE CONDITIONS OF ACCEPTABILITY BELOW.
"SQUARE CORNER" FOOD WARMERS
INSTALLATION INSTRUCTIONS
46033-1 REV (A)
INSTALLATION INSTRUCTIONS
BUILT-IN (BOTTOM MOUNT) INSULATED
MODELS BMW-206ST, STD
WELLS/BLOOMFIELD * VERDI, NV
ELECTRICAL
MODEL
VOLTS
WATTS
AMPS
PHASE
WIRING
TEMP.
FIELD
GAUGE
RATING
BMW-206ST
BMW-206ST
BMW-206ST
BMW-206STD
BMW-206STD
BMW-206STD
240
208
120
240
208
120
1200
1240
1650
1200
1240
1650
10.0
6.0
6.9
10.0
6.0
6.9
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
#14 AWG Cu
#14 AWG Cu
#14 AWG Cu
#14 AWG Cu
#14 AWG Cu
#14 AWG Cu
90°C MIN.
90°C MIN.
90°C MIN.
90°C MIN.
90°C MIN.
90°C MIN.
CUTOUT DETAILS
PRODUCT DIMENSIONS
UNIT MUST BE INSTALLED IN AN ALL METAL COUNTER.
NOTE: The BMW-206STD warmer is supplied with a drain hole
at one end and a 1/2 inch female N.P.T. drain nipple.
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. This appliance shall be installed in an all metal counter with
suitable wiring and control enclosures conforming to national and
local electrical codes.
2. Electrical component temperatures, including wiring, within and
surrounding the appliance must be monitored in the end use
installation for suitability.
3. Electrical grounding of all dead metal parts must be reliably
connected to the grounding means of the appliance and must
comply with requirements outlined in the appropriate Underwriters
Laboratories Inc. classification, national, and local electrical
codes.
4. Increased clearances are required if storage of combustible
materials is in close proximity to this appliance.
5. Unit shall be accessible for servicing from the bottom.
6. The name/rating plate information shall be accessible.
7. For water and waste connections: This appliance is to be
installed to comply with the applicable federal, state or local
plumbing codes.
THE INSTALLATION OF RECOGNIZED COMPONENT UNITS REQUIRES
ADDITIONAL EVALUATIONS TO UNDERWRITERS LABORATORIES INC.
STANDARDS.
METAL SHIELD
1/2 IN DRAIN NPT
BMW-206STD
SQUARE
CORNERS
(MAX TURN DOWN)
TOP CUTOUT
FRONT PANEL CUTOUT
PILOT
LIGHT
9 MIN
(229)
21 13/16
(554)
20 3/32
(510)
12 1/16
(306)
8 5/16
(211)
13 11/16
(348)
1/2
(13)
12 1/32
(306)
20 1/16
(510)
6 5/16
(160)
4 1/8
(105)
7/8
(22)
7/8
(22)
2 1/32
(52)
5/16
(8)
Ø
3/8
(10)
Ø
5/32
(4)
Ø
5/32
(4)
Ø
INCHES
(MM)