background image

10 Sunnen Drive

St. Louis, MO 63143

telephone: 888-356-5362

fax: 314-781-2714

www.wellsbloomfield.com

BLOOMFIELD INDUSTRIES

p/n 2M-

75854

 Rev. F  

 

 

 

 

 

 

      

 M622    

11

0501

622

OWNERS MANUAL

for

AIRPOT &

THERMAL SERVER

COFFEE BREWERS

MODELS

 

8778 

8780 

8782

 

8783 

8785 

8786

 

8788 

Includes:

Installation

Use & Care

Servicing Instructions

Model  8780  Brewer
with optional
7750 Thermal Server

Summary of Contents for 8778

Page 1: ...ellsbloomfield com BLOOMFIELD INDUSTRIES p n 2M 75854 Rev F M622 110501 622 OWNERS MANUAL for AIRPOT THERMAL SERVER COFFEE BREWERS MODELS 8778 8780 8782 8783 8785 8786 8788 Includes Installation Use C...

Page 2: ...y decanters excluded THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURP...

Page 3: ...DIAGRAMS 22 SPECIFICATIONS 1 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal MODEL STYLE VOLTS WATTS AMPS 1 POWER SUPPLY CORD 8778 THERMAL 120V 1800 15 NEMA 5 15P 8778CAk 120C 1500 12 5 NEMA 5...

Page 4: ...1 Features Operating Controls 2 IL1705 NOT AVAILABLE ON MODELS 8782 or 8785 AIROT BREWING POSITION HOT WATER FAUCET BREW SWITCH POUR OVER COVER POUR OVER OPENING READY TO BREW LIGHT 622 2M 75854 Owner...

Page 5: ...lishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read and understood by all operators and users Except a...

Page 6: ...your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solen...

Page 7: ...LLATION INSTRUCTIONS REFER TO ELECTRICAL SPECIFICATIONS Page 1 Check the nameplate to determine correct electrical service required for the Brewer to be installed IMPORTANT Before connecting to electr...

Page 8: ...cover then pour warm tap water into the pour over opening until water flows from the brew head When water stops dripping from the brew head empty the container Once the tank is full of water connect...

Page 9: ...water tank This forces an identical amount of hot water out of the tank and through the spray head into the brew chamber The solenoid uses a flow control device so that flow is consistent between 20...

Page 10: ...ver identical to the one being used with tap water Lift the pour over cover and pour the entire contents of the container into the pour over opening which will fill the basin Water from the basin will...

Page 11: ...d a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry 8 Wipe the exterior of the brewer with a soft clean cloth or sponge moistened with clean...

Page 12: ...w Brew chamber dispense hole plugged Thoroughly clean brew chamber Too much coffee or too fine a grind Adjust coffee amount and grind Sprays water from brew head Spray gasket improperly installed Chec...

Page 13: ...wo screws at the bottom and a retaining lip at the top SOLENOID DOOR Remove solenoid door to access solenoid and plumbing connections Solenoid door is held by two screws and a retaining lip Fig 9 Acce...

Page 14: ...and reinstall vent tube Fig 10 Checking and Adjusting Brew Temperature CAUTION SHOCK HAZARD These procedures involve exposed electrical circuits These procedures are to be performed by qualified tech...

Page 15: ...n plug REMOVE TANK LID ASSEMBLY Unplug brewer or turn circuit breaker OFF Turn OFF water supply Remove top panel Pull vent tube and inlet elbow out of basin pan Pull water inlet tube out of basin pan...

Page 16: ...se fitting b Pressure on the white ring toward the metal ferrule releases the clinch ring allowing the hose to be easily slid off of the solenoid bypass outlet c Install hose on new valve by pressing...

Page 17: ...valve is turned OFF Remove tank lid assembly per above Remove two hex nuts hot water coil to cover Pull coil from mounting holes Reassemble in reverse order REPAIR HOT WATER FAUCET Remove top panel an...

Page 18: ...body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solution according to the manufacturer s directions Carefully pour the deliming s...

Page 19: ...63 2T 47499 THERMOSTAT HI LIMIT ALL exc 8786 8788 2T 70716 THERMOSTAT HI LIMIT RESET 8786 8788 66 2V 70144 WATER INLET TUBE ALL 66a 2C 70146 NUT HEX 4 40 SS ALL 66b 2C 70145 SCREW 4 40 x 1 PAN HEAD A...

Page 20: ...FLAT 15 32 x 1 1 8 x 1 16 SS 8780 8782 8786 8788 29 WS 82556 FAUCET ASSEMBLY PRESSURE 8780 8782 8786 8788 33 2I 70139 GASKET SPRAY HEAD ALL 34 A6 82727 SPRAY DISK EMBOSSED ALL 34a A6 70163 RETAINER SP...

Page 21: ...EU 230V UNITS 37 2K 70215 STRAIN RELIEF 8778 80 82 83 85 2K 70648 STRAIN RELIEF SMALL UK EU 230V UNITS 43 2E 70709 TERMINAL BLOCK 4P 8786 8788 45 2E 75753 SOLENOID W BYPASS 120V 50 GPM 8780 8782 8786...

Page 22: ...EXPLODED VIEW PARTS LIST continued CABINET COMPONENTS 21 IL1711 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...

Page 23: ...8782TFL 8785 AL 8785 ALP A6 74693 BODY WRAP 8786 1086 8786TF A6 74773 BODY WRAP 8788 8788AF 102 A6 72292 PANEL FRONT 8780TF 8786TF 8778 T A6 74811 8782AF 8785 A 8788AF DD 74900 8782AFL A6 74793 8782TF...

Page 24: ...RING DIAGRAM BROWN 230V BLACK 14 GA WHITE 14 GA BLUE 230V 120VAC POUR OVER 1800 WATT MODELS 8778 8783 8785 1500 WATT Canadian MODELS 8778CA 8783CA 8785CA 120VAC AUTOMATIC 1800 WATT MODELS 8780 8782 87...

Page 25: ...WIRING DIAGRAM continued 23 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...

Page 26: ...622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal NOTES...

Page 27: ...NOTES 622 2M 75854 Owners Manual Gourmet 1000 Airpot Thermal...

Page 28: ...10 Sunnen Drive St Louis MO 63143 telephone 888 356 5362 fax 314 781 2714 www wellsbloomfield com...

Reviews: