background image

INSTRUCTION MANUAL

One Jake Brown Road 

Old Bridge, NJ 08857-1000 USA 

(800) 523-6049 • (732) 679-4000 • FAX: (732) 679-4353

 

www.blondertongue.com

©2010 Blonder Tongue Laboratories, Inc.  All rights reserved.  Specifications are subject to change without notice.  Trademarks are the property of their respective owner.

BIDA Series

Broadband Indoor Distribution Amplifiers - Active Return Path

 

Model 

Stock No.

  BIDA 86B-30 

5900-83 

  BIDA 86B-30P 

5900P83 

  BIDA 86B-43 

5900-84 

  BIDA 86B-43P 

5900P84 

651213600B

Description

The Blonder Tongue BIDA-ARP is a completely self-contained broadband indoor distribution amplifier designed specifically for 

CATV and SMATV signal distribution systems which use a cable drop as a signal source. Four models are available; #5900-84, 

-83, P83 and P84 with a 54 to 860 MHz bandpass. The basic amplifier is configured for two-way operation with a passive sub-

channel return path for 5 to 42 MHz bandpass.

The #5900-84 and P84 have a flat operating gain of 43 dB minimum. The #5900--83 and P83 have a gain of 30 dB minimum. 

(See Specifications for typical values of each model.)  All models have a return gain of about 20 dB when in the active mode. 

Lower operating gains can be achieved by adjusting the variable attenuator. All models can be attenuated over a range of 10 dB in 

the forward path and 18 dB in the return path. Gain and slope controls are located on the front panel for easy set-up and ad just-

ment. Two -30 dB backmatched test points are provided to permit testing without interruption of service.
In applications where input signals are too high or where greater cable equalization is necessary, the BIDA-ARP can be reconfig-

ured by using plug-in fixed attenuators (forward and return) and cable slope equalizers (forward) to meet particular requirements.
Push-pull, hybrid IC modules enable the BIDA-ARP to operate at high output levels while retaining low distortion characteristics.
The aluminum chassis is designed to provide excellent heat dissipation thus allowing operation at high ambient temperatures with 

no degradation of performance or reliability.

Features

  •  Provides Two-Way Capability with an Active or Passive Return Path Set by Field-Changeable Jumpers.
  •  Hybrid IC Circuitry for High Output with Low Distortion.
  •  Front Panel Gain and Slope Controls for Easy Adjustments.
  •  Sockets for Hybrid IC to Make a Hybrid IC Change in the Field.
  •  Forward Path Input-Side Plug-In Fixed Attenuator and Cable Equalizer for Optimum Per for mance.
  •  Return Path Output-Side Fixed Attenuator for Optimum Performance.
  •  Externally Accessible Test Points Permit In-Service Testing.
  •  Exceeds FCC Specs for Both Conducted and Radiated Interference at Full Output Level.
  •  External “UL Listed” Power Transformer.

Summary of Contents for BIDA 86B-30

Page 1: ...d over a range of 10 dB in the forward path and 18 dB in the return path Gain and slope controls are located on the front panel for easy set up and ad just ment Two 30 dB backmatched test points are provided to permit testing without interruption of service In applications where input signals are too high or where greater cable equalization is necessary the BIDA ARP can be reconfig ured by using p...

Page 2: ...operate the unit Retain all safety and operating instructions for future reference Heed all warnings on the unit and in the safety and operating instructions WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE NOTE TO CATV SYSTEM INSTALLER This reminder is provided to call the CATV System Installer s attention to Article 820 40 of the NEC that provides guidelines fo...

Page 3: ...ring a lightning storm or when the unit is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the lines between the unit and the antenna This will prevent damage caused by lightning or power line surges Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can fall into such power lines or circuits W...

Page 4: ...E CONTROL CIRCUIT 54 MHz HPF2 42 MHz LPF2 ATT INPUT OUTPUT 30 dB TEST 54 MHz HPF1 42 MHz LPF1 ATT GAIN CONTROL FULL GAIN CONTROL RETURN AMPLIFIER J11 24V J13 P3 P1 FLAT ATTENUATOR PASSIVE PASSIVE ACTIVE ACTIVE P2 ON OFF J12 PASSIVE RETURN PATH NOTE Passive Return Path Short Plug P1 on J11 and P3 on J13 to passive and P2 on J12 to off Active Return Path Short Plug P1 on J11 and P3 on J13 to active ...

Page 5: ...l dBmV 44 42 Composite Triple Beat dB CTB 48 56 50 60 Crossmodulation dB XMOD 48 56 54 60 2nd Order Composite dB CSO 54 58 56 8 5 129 44 56 61 58 60 Impedence ohms 75 Hum Modulation dB 70 65 Input Output Test Port Level dB 30 2 Input Output Test Port Return Loss dB 20 Operating Temperature Range 20 to 60 Power Requirements Wall Power Transformer 105 130 VAC 60 Hz 0 38 AMP MAX Size LxWxH 10 1 2 x 7...

Page 6: ...k wise After in sert ing CableEqualizer rotate Cable Equalizer clamp counter clockwise so it lays atop the mount ing tab Tighten mounting screw to secure Ca ble Equalizer clamp po si tion View A Specify dB value BIDA FA Flat Attenuator Stock No 5411A Plug in flat attenuator pad for reducing forward and or return gain in BIDA series amplifiers The BIDA FA is avail able in fixed values of 1 20 dB in...

Page 7: ...stered trademarks of Motorola Corp Rev 5 6 2009 Blonder Tongue Laboratories Inc Limited Warranty Blonder Tongue Laboratories Inc BT will at its sole option either repair or replace with a new or factory reconditioned product as BT may determine any product manufactured by BT which proves to be defective in materials or workmanship or fails to meet the specifications which are in effect on the date...

Page 8: ...One Jake Brown Road Old Bridge NJ 08857 1000 USA 800 523 6049 732 679 4000 FAX 732 679 4353 www blondertongue com ...

Reviews: