VCT: Virtual Channel Table (VCT) allows the user to choose from the following options:
CVCT: Cable Virtual Channel Table
TVCT: Terrestrial Virtual Channel Table
OFF
: Turns the VCT off.
Program Source:
Displays the RF Input that the channel is being sourced from as well as the source stream name.
Program Number:
The user must enter a unique output program number for each program.
Short Name: The user may enter a short name for the channel. Up to 7 alphanumeric characters are allowed.
Major Ch.: The user may enter a major channel number for the output program. The range is 1 to 99 for Terrestrial
and 1 to 999 for Cable.
Minor Ch.:
The user may enter a minor channel number for the output program. The range is 1 to 99 Terrestrial and
0 to 999 for Cable.
6.5 TS Config > Basic Configuration (continued)
6.6 TS Config > Advanced Configuration
Pgm PID Base: The Program PID Base sets the first programs output PID number to this starting base number.
Next Pgm PID Base: The Next Program PID Base sets the next programs starting output PID number by incrementing
this value higher than the previous program's output PID number.
NOTE: It is recommended that this value be +16 above the Pgm PID base value. This is not a requirement, but will help
in guiding a user who is changing things but does not understand what they are doing. By default, this value is set to
64 which is 48+16 (48 being the default program pid base value).
5
2
4
3
1
6
7
8
Figure 6.6 - “Cherry Picking” > “TS Config” Tab - Full View (Advanced Configuration)
1
2
3
5
6
4
NOTE: For one-part channel numbers (CVCT only), set the minor channel to 0,
and the major channel to the desired one-part channel number.
To toggle into “Advanced Configuration” (Figure 6.6), click the plus sign ( ) next to Basic Configuration. The additional