Page 2: ... Zoom EXA Fixtures 7 Data DMX Cables 7 Using this fixture with the wiCICLE Wireless DMX System 8 Cable Connectors 10 3 Pin 5 Pin Huh 10 Take It To The Next Level Setting up DMX Control 10 Fixture Linking Master Slave Mode 11 Mounting Rigging 11 4 Operating Adjustments 12 Navigating The Control Panel 12 Control Panel Menu Structure 13 DMX Mode 14 Manual Color Mixing 14 Static Colors Built In Progra...
Page 3: ...upply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your unit mat...
Page 4: ...e before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unski...
Page 5: ... female output Dual mounting yoke allows flexibility in positioning Heavy duty black aluminum housing Able to directly power the wiCICLE wireless system via DMX PowerCON compatible power in out connectors CONTROL USITT DMX 512 14 Channel 3 pin Input Output LED 4 button control panel DMX Quick Reference 14 Channel Mode Channel Channel 1 Zoom wide narrow 2 Master Dimmer 0 100 3 Strobe slow fast 4 Re...
Page 6: ...1 Puck Pro Zoom Pin Up Picture Locking Knobs Figure 2 The Rear Connections LED Control Panel Display Dual Mounting Brackets DMX Out Control Panel Buttons Power In Power Out DMX In Carrying Handle Safety Point Anodized Extruded Aluminum Enclosure RGBAW UV LEDs w Zoomable Optics Cooling Fan ...
Page 7: ...can support Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Da...
Page 8: ... CIRCUMSTANCES IS BLIZZARD LIGHTING RESPON SIBLE FOR ANY DAMAGE FROM SUCH OPERATION Fixtures bearing the above logo MUST only use cable and connectors which separate chassis case ground from cable shielding Cabling with the shield connected to the connector s case chassis may cause malfunc tion and damage to the wiCICLE or fixture wiCICLE transmitters have additional power requirements and therefo...
Page 9: ...let s proceed 1 Plug the wiCICLE Receiver into the DMX IN connector of the fixture and verify it is receiving power the STATUS LED should illuminate 2 Connect the AC DC adaptor to the the wiCICLE Transmitter and verify it is receiving power the STATUS LED should illuminate 3 Press the RECESSED SELECTOR BUTTON on the Transmitter to select the operating channel group The system will store this setti...
Page 10: ...If you d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used No Connection No Connection Not Used No Connection No Connection Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector outpu...
Page 11: ...g Check the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the f...
Page 12: ...e through the various control panel menus MODE Is used to navigate the various modes SETUP Is used to enter into the selected mode setup UP Scrolls through menu items and numbers in ascending order DOWN Scrolls through menu items and numbers in descending order The control panel LED display shows the menu items listed on the control panel menu structure on page 13 Use the MODE button to navigate y...
Page 13: ...MX address rL rL00 rL99 Red Intensity 0 100 9L 9L00 9L99 Green Intensity 0 100 bL bL00 bL99 Blue Intensity 0 100 AL AL00 AL99 Amber Intensity 0 100 UL UL00 UL99 White Intensity 0 100 PL PL00 PL99 UV Intensity 0 100 Pr Pr01 Pr43 Static Colors Auto Sound Active 1 43 SP SP01 SP16 Speed slow fast TEST ENTER Test Mode REST ENTER Reset the Fixture ...
Page 14: ...e intensity level from 0 99 3 Press the ENTER button to confirm Amber 1 Navigate the menu using the MENU button until you reach AL 2 Use the UP DOWN buttons to adjust the intensity level from 0 99 3 Press the ENTER button to confirm White 1 Navigate the menu using the MENU button until you reach UL 2 Use the UP DOWN buttons to adjust the intensity level from 0 99 3 Press the ENTER button to confir...
Page 15: ...y 0 100 7 000 255 Amber Intensity 0 100 8 000 255 White Intensity 0 100 9 000 255 UV Intensity 0 100 10 000 020 021 040 041 060 061 080 081 100 101 120 121 140 141 160 161 180 181 200 201 220 221 255 Gradual Color Mixing R G R B G R G B B G R G B W R B G W A P B A R G A P A W P R B G A P W R G B A W P 11 000 060 061 120 121 180 181 244 245 255 Built in Programs No Function Color Snap Color Fade Co...
Page 16: ...nnected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting channel number that it will respond to For example if two 6 channel fixtures are used ...
Page 17: ... client s satisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t beha...
Page 18: ... Beam Angle 25 45 degree zoomable beam angle Luminous Intensity Lux per meter Red Green Blue Amber White UV All Narrow 1m 1 262 1 586 1 625 1 126 2 342 574 6 350 2m 386 505 525 318 656 196 1 660 Wide 1m 1 070 1 284 1 297 935 1 674 422 5 670 2m 326 389 392 295 496 161 1 204 Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Control Protocol USITT DMX 512 DMX Channels 14 Channels Input 3 ...