Product overview
Version 2.1
Cube 1, Cube Range 1
17
3 .3 .6
Technical specif ications
OPTICAL PERFORMANCE
a
Cube 1
Cube Range 1
Typical application range
1.5 – 75 m
5 – 150 m
Detection range
250 m (> 30 m for 10 %
reflectivity target,
pixel-filling, 100 klux,
90 % detection rate,
false positive rate < 0.2 %,
0.6° horizontal angular
spacing)
250 m (> 50 m for 10 %
reflectivity target,
pixel-filling, 100 klux,
90 % detection rate,
false positive rate < 0.2 %,
0.36° horizontal angular
spacing
b
)
Range resolution
< 1 cm
Maximum field-of-view
(Horizontal x vertical)
70° x 30°
18° x 12°
Vertical resolution
5 – 400 scan lines per frame
c
(user-configurable)
5 – 200 scan lines per frame
c
(user-configurable)
Horizontal resolution
0.4° – 1.0°
(user-configurable)
0.24° – 0.4°
(user-configurable)
Scan rate
> 500 scan lines per second
Frame rate
1.5 – 50 Hz (dependent on
configured scan lines and
vertical field-of-view)
Examples:
• 70° x 30°, 200 scan lines,
min. 2.5 Hz.
• 70° x 25°, 50 scan lines,
min. 10 Hz.
• 70° x 10°, 20 scan lines,
min. 25 Hz.
2.5 – 50 Hz (dependent on
configured scan lines and
vertical field-of-view)
Examples:
• 18° x 12°, 200 scan lines,
min. 2,5 Hz.
• 18° x 12°, 32 scan lines,
min. 15 Hz.
• 18° x 8°, 16 scan lines,
min. 30 Hz.
Number of returns
3
d
3
a
Measured at 25 °C, 60 % rel. humidity, single return.
b
The effective detection range drops at the edges of the field-of-view.
c
For less than 26 scan lines (Cube), respectively 18 scan lines (Cube Range) a reduced vertical
field-of-view must be configured (see frame rate).
d
Starting from a distance of 5 m. Only single returns at closer distances.