TROUBLESHOOTING cont.
SYMPTOM
ACTION
Sooty deposits on the glass door.
1.
If the fl ame is yellow and lazy, check for lint etc. around primary
air shutter. Increase primary air by opening the primary air
shutter if necessary, see “SERVICING” on page 34.
2.
Check for proper placement of the logs and branches. Ensure
logs and burner are clean, see “ASSEMBLY INSTRUCTIONS
cont.” on page 10.
3.
Check for proper venting and blockage of the vent termination.
4.
Check manifold pressure and clock input rating for over-fi ring.
Sharp blue fl ames with fl ames lifting off the
burner at the ends.
1.
Too much primary air. Reduce primary air by closing the primary
air shutter. During cold temperatures, some fl ame lifting may
occur during start-up, see “SERVICING” on page 34.
Convection blower does not turn on.
1.
The convection fan is thermostatically controlled. It will only turn
on when the appliance is warmed-up. This may take up to 5
minutes with the appliance on high.
2.
Check for 120VAC electrical supply to the appliance. (Is the cord
plugged in?)
3.
Check if speed controller is not in OFF position
4.
Check electrical connections.
5.
Check for defective convection blower speed controller.
6.
Check for defective convection blower.
Summary of Contents for TORINO II 1606
Page 7: ...OM 1606 E V1 03 April 2 2014 Page 7 TORINO II Freestanding 1606 APPLIANCE DIMENSIONS ...
Page 26: ...OM 1606 E V1 03 April 2 2014 Page 26 TORINO II Freestanding 1606 LIGHTING INSTRUCTIONS ...
Page 36: ...OM 1606 E V1 03 April 2 2014 Page 36 TORINO II Freestanding 1606 FUEL CONVERSION cont ...
Page 44: ...OM 1606 E V1 03 April 2 2014 Page 44 TORINO II Freestanding 1606 REPLACEMENT PARTS cont ...
Page 49: ...OM 1606 E V1 03 April 2 2014 Page 49 TORINO II Freestanding 1606 NOTES ...