OM-1606 E V1.03
April 2, 2014
Page 40
TORINO II Freestanding 1606
ALLOWABLE TERMINATION LOCATIONS
____________________________________________________________________________________________________
A= Clearance above grade, veranda
*(min. 12”/30 cm)
*(min. 12”/30 cm)
porch, deck or balcony
____________________________________________________________________________________________________
B= Clearance to w indow or door
*(min. 12”/30 cm)
*(min. 12”/30 cm)
that may be opened
____________________________________________________________________________________________________
C= Clearance to permanently closed
*(min. 12”/30 cm)
*(min. 12”/30 cm)
w indow
____________________________________________________________________________________________________
D= Vertical clearance to ventilated
*min. 25-1/2” (65 cm)
*min. 25-1/2” (65 cm)
soffit located above the terminal
check w ith local
check w ith local
from the centerline of the terminal
code
code
________________________________________________________________________________
E= Clearance to unventilated soffit
*min. 25-1/2” (65 cm)
*min. 25-1/2” (65 cm)
from the centerline of the terminal.
____________________________________________________________________________________________________
F=Clearance to outside corner
*min. 10”/25cm
*min. 10”/25cm
from the centerline of the terminal.
____________________________________________________________________________________________________
G=Clearance to inside corner
*min. 16”/40cm
*min. 16”/40cm
the centerline of the terminal.
____________________________________________________________________________________________________
H= Clearance to each side of centerline
3’ (91cm) w ithin a height 15’ (4.5m)
*
extended above meter/regulator assembly
above the meter/regulator assembly
____________________________________________________________________________________________________
I= Clearance to service regulator vent outlet
3’ (91cm)
*
____________________________________________________________________________________________________
J= Clearance to no mechanical air supply inlet
12” (30cm)
9” (23cm)
to building or the combustion air inlet to any
other appliance
____________________________________________________________________________________________________
K= Clearance to a mechanical air supply inlet
6’ (1.83 m)
3’ (91 cm) above if w ithin 10’ (3 m)
horizontally
____________________________________________________________________________________________________
L= Clearance above paved sidew alk or paved
7’ (2.13 m)†
*
drivew ay located on public property
____________________________________________________________________________________________________
M = Clearance under veranda, porch, deck or
12” (30 cm)‡
*
balcony
____________________________________________________________________________________________________
1
In accordance w ith the current CSA B149.1,
Natural Gas and Propane Installation Code
2
In accordance w ith the current ANSI Z223.1/NFPA 54,
National Fuel Gas Code
† A vent shall not terminate directly above a sidew alk or paved drivew ay that is located betw een tw o single family dw ellings
and serves both dw ellings.
‡ Permitted only if veranda, porch, deck or balcony is fully open on a minimum of tw o sides beneath the floor.
* For clearances not specified in
ANSI Z223.1/NFPA 54
or
CSA B149.1
, one of the follow ing shall be indicated:
a) A minimum clearance value determined by testing in accordance w ith section 2.23.7, or ;
b) A reference to the follow ing footnote: “Clearance in accordance w ith local installation codes and the requirements of the gas
Summary of Contents for TORINO II 1606
Page 7: ...OM 1606 E V1 03 April 2 2014 Page 7 TORINO II Freestanding 1606 APPLIANCE DIMENSIONS ...
Page 26: ...OM 1606 E V1 03 April 2 2014 Page 26 TORINO II Freestanding 1606 LIGHTING INSTRUCTIONS ...
Page 36: ...OM 1606 E V1 03 April 2 2014 Page 36 TORINO II Freestanding 1606 FUEL CONVERSION cont ...
Page 44: ...OM 1606 E V1 03 April 2 2014 Page 44 TORINO II Freestanding 1606 REPLACEMENT PARTS cont ...
Page 49: ...OM 1606 E V1 03 April 2 2014 Page 49 TORINO II Freestanding 1606 NOTES ...