INSTALLATION INSTRUCTIONS cont.
GAS CONNECTIONS
Have your gas supplier or a qualifi ed gas fi tter run a gas supply line into the gas fi replace. Th
e line must be
properly sized and fi tted according to the installation codes. Upstream of the supply connection, the fi tter shall
provide a manual shut-off valve.
CAUTION:
The appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure-testing of that system at test pressures in
excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply
piping system by closing its individual manual shutoff valve during any pressure-
testing of the gas supply piping system at test pressures equal to or less than 1/2
psig (3.5 kPa). Failure to do so will damage the appliance’s gas valve. Such damage
is not cover by the manufacturer’s warranty.
BE SURE TO TIGHTEN THE PRESSURE TAP SET SCREW AFTER CHECKING THE PRESSURE.
Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is
designed for the gas type you are using. Th
e gas type markings are located on the certifi cation label and also on
the appliance’s gas valve.
Adequate clearance for proper installation and checking of the
gas connections must be provided. All gas connections must be
checked for gas leaks.
Pedestal Access
Th
e pedestal / gas controls can be accessed for set up or servicing
and adjusting. Th
e pedestal rear cover can be removed with 4
screws, while the front lift s off 2 hooks and magnets. Use care
when removing these parts that you do not accidentally scratch
the paint on the pedestal base. When the covers are removed,
you should have easy access for connections and testing
purposes. Re-install these components aft er servicing, again,
being careful not to damage the painted services of the stove.
• Check for proper gas supply pressure by loosening the set screw on supply pressure tap on the gas valve
with a small fl at tip screw driver and placing a test gauge on the tap.
• Check for proper gas supply pressure by loosening the set screw on supply pressure tap on the gas valve
with a small fl at tip screw driver and placing a test gauge on the tap.
• Th
e minimum permissible gas supply pressure is 5.0 in. w.c. (1.24 kPa) for natural gas and 12.0 in. w.c.
(3.0 kPa) for propane. Maximum gas supply pressure should never exceed 14.0 in. w.c. (3.48 kPa) or 1/2
psi. for both natural gas and propane.
Summary of Contents for TORINO II 1606
Page 7: ...OM 1606 E V1 03 April 2 2014 Page 7 TORINO II Freestanding 1606 APPLIANCE DIMENSIONS ...
Page 26: ...OM 1606 E V1 03 April 2 2014 Page 26 TORINO II Freestanding 1606 LIGHTING INSTRUCTIONS ...
Page 36: ...OM 1606 E V1 03 April 2 2014 Page 36 TORINO II Freestanding 1606 FUEL CONVERSION cont ...
Page 44: ...OM 1606 E V1 03 April 2 2014 Page 44 TORINO II Freestanding 1606 REPLACEMENT PARTS cont ...
Page 49: ...OM 1606 E V1 03 April 2 2014 Page 49 TORINO II Freestanding 1606 NOTES ...