OM-1606 E V1.03
April 2, 2014
Page 11
TORINO II Freestanding 1606
INSTALLATION INSTRUCTIONS
PRECAUTIONS
• Th
is appliance must be installed by a qualifi ed gas installer and the installation conform to the
installation codes.
• Th
is appliance needs fresh air for safe operation and must be installed so there are provisions for
adequate ventilation air. Provide adequate clearance around air openings of the appliance. Never obstruct
front openings.
• Provide adequate clearances for proper operation and servicing of the appliance.
• Th
is appliance must be properly connected to a venting system.
• Th
is appliance must NOT be connected to a chimney fl ue serving a solid-fuel appliance.
LOCATING GAS FIREPLACE
Th
e venting system of this appliance must be installed in a location that is free of plumbing, electrical wiring
and heating or air conditioning ducts. Select a location that is accessible for venting. See “ALLOWABLE
TERMINATION LOCATIONS” on page 40, in this manual.
Mobile Home Installation:
Two holes are provided in the pedestal base of the unit to allow for anchoring down the appliance. To access the
mounts simply remove the pedestal back panel, or lift off the pedestal valve access panel at the front of the unit.
Th
e pedestal back unscrews with 4 screws, the pedestal front lift s off 2 hooks and 2 magnets. Lift up and pull
towards you.
VENT TERMINATION LOCATION
1. Establish a suitable vent termination location, see “ALLOWABLE TERMINATION LOCATIONS” on
page 40
2. In heavy snowfall areas make sure vent termination is located where it can not be blocked by snowfall or
snow from snow removal equipment.
3. Locate vent termination away from plants, bushes or any other object on or near the vent termination
that will interfere or obstruct the air fl ow around it.
4. DO NOT recess vent termination into walls, sidings or planters.
5. Vent terminations located below 7 ft (2130 mm) from grade level or anywhere that it is a burn hazard to
the public, such as patios and balconies, must be protected with an approved termination cage.
Summary of Contents for TORINO II 1606
Page 7: ...OM 1606 E V1 03 April 2 2014 Page 7 TORINO II Freestanding 1606 APPLIANCE DIMENSIONS ...
Page 26: ...OM 1606 E V1 03 April 2 2014 Page 26 TORINO II Freestanding 1606 LIGHTING INSTRUCTIONS ...
Page 36: ...OM 1606 E V1 03 April 2 2014 Page 36 TORINO II Freestanding 1606 FUEL CONVERSION cont ...
Page 44: ...OM 1606 E V1 03 April 2 2014 Page 44 TORINO II Freestanding 1606 REPLACEMENT PARTS cont ...
Page 49: ...OM 1606 E V1 03 April 2 2014 Page 49 TORINO II Freestanding 1606 NOTES ...