180-CL26.SP.1 v1.00
July 30, 2020
Page 5
CL26.SP.1
APPLIANCE CERTIFICATION
This appliance is tested and certified to the following US and Canadian gas appliance standards:
• ANSI Z21.88-2017
/ CSA 2.33-2017 - Vented Gas Fireplace Heaters
• CSA 2.17-2017 - Gas-Fired Appliance for Use at High Altitudes
•
CSA P.4.1-15 - Testing Method for Measuring Annual Fireplace Efficiency
SPECIFICATIONS
MODEL
CL26.SP
Natural Gas (NG)
Propane (LPG)
Manifold Pressure
3.8” w.c. (0.95kPa)
10.6” w.c. (2.64 kPa)
Min. Supply Pressure for
Purpose of Input Adjustment
7.0” w.c. (1.74 kPa)
11.0” w.c. (2.74 kPa)
Orifice Size
DMS #39
DMS #1.5 mm
Nominal Input Rating
27,300 BTU/hr
26,200 BTU/hr
Minimum Input Rating
14,838 BTU/hr
14,120 BTU/hr
Altitude
0 - 4,500 ft. (0 - 1372 m)
0 - 4,500 ft. (0 - 1372 m)
Primary Air Opening
50% (Minimum)
open
Electrical Rating
120 V.A.C. System
120 V.A.C. System
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly de-
rated and installed according to local codes, in the absence of local codes, with the current National Fuel Gas
Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CSA-B149.1, in Canada.
GENERAL INFORMATION
INSTALLATION CODES
This appliance must be installed by a qualified gas
appliance installer. This appliance is certified for
installation in a bedroom or a bedsitting room. This
appliance is only for use with the type of gas indicated on
the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where
not prohibited by local codes. This appliance is not
convertible for use with other gases, unless a certified kit
is used. Only for direct discharge without duct connection.
This appliance must be direct vented using listed and
approved Simpson Dura-Vent, Selkirk, Security or
American Metal Products vent components.
We recommend
that our gas hearth
products be installed
and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute (NFI) as NFI
Gas Specialists.
STEADY STATE EFFICIENCY
Natural Gas (NG) Propane (LP)
Steady State Efficiency - High
Effy
SS,H
71.55%
65.75%
Fireplace Efficiency
FE
64.49%
59.41%