OPERATING INSTRUCTIONS
WALL MOUNTING
The Proflame remote control is supplied with an adapter
for wall mounting. Install the controller 1.5 m above floor level,
well away from heat sources, kitchens, doors or windows. Metallic
structures or radio interferences can reduce the operative distance
of the device. Make sure to attach the adapter in a level plane
without any distortion. Proceed as below:
• Detach the adapter from the body of the remote control
wall transmitter. (
Fig. 3
)
• Position the adapter on the wall, mark the points for the
fixing holes and drill the wall.
• Fix the adapter on the wall using the mounting hardware
supplied with the remote control.
• Insert the remote control onto the adapter. (
Fig. 4
)
OPERATING PROCEDURE
Initializing the System for the First Time
Power the IFC control. Install the 3 AAA type batteries in the
Transmitter battery bay, located on the base of the Transmitter.
(
Fig. 5
) With the batteries already installed in the Transmitter,
push the red “sync” button on the IFC control. Next push the On
button on the Transmitter. The IFC control will “beep” to indicate
the Transmitter’s command is accepted and sets to the particular
code of that Transmitter. The system is now initialized.
Temperature Indication Display
With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same
time. Look at the LCD screen on the Transmitter to verify that a C or F is visible to the right of the Room
Temperature display. (
Fig. 6 & 7
)