BLAUBERG Turbo 100 User Manual Download Page 1

USER’S MANUAL

Turbo

INLINE MIXED-FLOW FANS

EN

Summary of Contents for Turbo 100

Page 1: ...USER S MANUAL Turbo INLINE MIXED FLOW FANS EN ...

Page 2: ...livery set 6 Brief description 6 Operation guidelines 7 Designation key 8 Installation 9 Electronics operation algorithm 10 Technical maintenance 12 Storage and transportation regulations 12 Manufacturer s warranty 13 ...

Page 3: ...ace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is correct at the time of the document s preparation The Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to incorporate the latest technological developments No part of this publ...

Page 4: ...OLLOW THE USER S MANUAL REQUIREMENTS TO ENSURE DURABLE AND TROUBLE FREE OPERATION OF THE UNIT SAFETY INSTRUCTIONS Disconnect the unit from power supply prior to any connection servicing maintenance and repair operations Only qualified electricians with a work permit for electrical units up to 1000V are allowed for installation and maintenance The present user s manual should be carefully read befo...

Page 5: ...t avoid compression of the casing Deformation of the casing may result in the motor jam and noisy operation Misuse of the unit and any unauthorised modifications are not allowed Take steps to prevent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion an...

Page 6: ...ory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Ensure that the fan is switched off from the supply mains before removing the guard The fan is to be installed so that the blade...

Page 7: ...xtract ventilation of premises The fan is designed for connection to ø 100 125 150 160 200 250 and 315 mm air ducts The unit is equipped with a two speed motor Ø D B H L Turbo 100 97 195 8 226 255 302 5 Turbo 125 123 195 6 226 255 258 5 Turbo 150 148 220 1 247 265 289 Turbo 160 158 220 1 247 265 289 Turbo 200 199 239 261 278 295 5 Turbo 250 247 287 323 340 383 Turbo 315 310 362 408 424 445 Turbo X...

Page 8: ...gress protection rating against access to hazardous parts and water ingress is IPX4 The unit is rated as a Class II electrical appliance The fan is rated for operation at the ambient air temperature from 1 C up to 40 C Power supply V Hz Transported air temperature C 220 240 50 25 60 220 60 25 40 IF THE POWER CORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER CUSTOMER SERVICE OR SIMILAR QUALIF...

Page 9: ...speed controller with an electronic thermostat and an integrated temperature sensor Timer based operation logic GT1 speed controller with an electronic thermostat and an outdoor temperature sensor fixed on a 4 m cable Timer based operation logic GSl1 speed controller with an electronic thermostat and an integrated temperature sensor Temperature based switching on off GS1 speed controller with an e...

Page 10: ...must always be connected to the air duct The fan mounting sequence is shown in Fig 3 11 and 14 19 The fan wiring diagrams are shown in Fig 12 13 Some fan models are equipped with a plastic limit stop in front of the L1 terminal Remove the limit stop for connection to the L1 terminal Designation L1 minimum speed terminal L2 maximum speed terminal QF automatic circuit breaker S external speed contro...

Page 11: ...t of the fan parameters Use exclusively the delivered plastic screwdriver to adjust the turn off delay time Do not use a metal screwdriver knife etc for adjustment operations not to damage the circuit board The Turbo XXX U U1 U2 n fan is equipped with an electronic TSC control unit speed controller with electronic thermostat for automatic speed control air flow control depending on the air tempera...

Page 12: ...as the room air temperature exceeds the set point As the room air temperature drops down below the temperature set point the timer starts 5 minutes countdown and then the fan switches to the set speed Turbo XXX U2 n As the indoor air temperature exceeds the set point the fan switches to the maximum speed As the air temperature drops 2 C below the set point or if the initial temperature is below th...

Page 13: ... dirt and dust Fig 24 30 Disconnect the fan from power mains prior to any maintenance operations To clean the fan use a soft cloth or a brush wetted in a mild detergent solution Do not allow water or liquid come into contact with electric components Fig 30 Wipe the surfaces dry after cleaning ...

Page 14: ...ndling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage The unit must be transported only in the working position Avoid sharp blows scratches or rough handling duri...

Page 15: ...d with installation reinstallation or transporting the product Additional information Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement of the purchased product for a major failure of the product You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not...

Page 16: ... STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE FREE OPERATION OF THE UNIT USER S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT THE PAYMENT DOCUMENT AND THE USER S MANUAL WITH THE PURCHASE DATE STAMP ...

Page 17: ...17 EN min 1 m 1 2 ...

Page 18: ...18 EN QF 3 4 5 6 ...

Page 19: ...19 EN 7 8 9 10 11 ...

Page 20: ...20 EN MAX MIN MAX MIN N L2 N L QF QF N L1 L2 S N L M N L1 N L QF M M L2 L1 N L M MAX 12 Turbo XXX ...

Page 21: ... MAX MIN L2 L1 N L X N L ST QF N L LT L1 X S N L ST QF N L LT L1 X L2 N L ST QF N L LT X N L ST QF N L LT L1 X S N L ST QF N L LT L1 X N L ST QF N L LT L2 X 13 TERMINAL BLOCK FOR 5 CONTACTS TERMINAL BLOCK FOR 4 CONTACTS Turbo XXX T ...

Page 22: ...22 EN 25 QF 14 15 16 17 18 19 ...

Page 23: ...23 EN 3030 min 2 min MIN MAX STOP 20 21 ...

Page 24: ...24 EN 33 min max 22 23 Thermostat control knob Speed control knob Speed control knob Turbo Gl1 GTl1 GSl1 Turbo FR1 Turbo G1 GT1 GS1 ...

Page 25: ...25 EN 24 25 26 27 ...

Page 26: ...26 EN 18 28 29 30 ...

Page 27: ...27 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date ...

Page 28: ...Blauberg_Australasia_B77EN 04 www blaubergventilation com au Turbo 100 Т l 1 125 US 150 G 160 200 250 315 ...

Reviews: