OPERATION MANUAL
KAMIN
CHIMNEY CENTRIFUGAL FAN
Page 1: ...OPERATION MANUAL KAMIN CHIMNEY CENTRIFUGAL FAN ...
Page 2: ...Storage and transportation rules 3 Manufacturer s warranty 3 Fan design 4 Delivery set 4 Modifications and options 4 Technical data 5 Operating logic 7 Mounting and operation guidelines 9 Mounting sequence 9 Installation and connection to power mains 10 Maintenance 11 Warranty card 12 ...
Page 3: ...or use in an inflammable and explosive medium The transported medium must not have an aggressive effect on steel at the temperature stated in the table 1 of the section Technical data Do not close or block the fan intake or exhaust vent not to disturb the normal air passage Do not sit on the fan and do not put objects on the fan Follow the manual guidelines to ensure trouble free operation and lon...
Page 4: ...a removable metal mixing chamber with an integrated temperature control damper and a G3 filter for transported air purification The mixing chamber is fixed to the fan casing with quick release latches for easy mixing chamber removal for cleaning fig 3 KF mixing chamber provides cold air supply when air temperature exceeds 90 C and hot air removal when the fan is off GF special accessory not includ...
Page 5: ...70 RPM min 1 1335 1250 1165 1310 1110 Noise level 3 m dBA 37 38 39 45 39 Max transported air temperature C 150 150 150 150 150 Ingress Protection Rating IP X2 IP X2 IP X2 IP X2 IP X2 Table 1 Technical data Allowable deviation of the rated voltage 10 Noise level is measured at 3 m distance from the fan connected to the air ducts in free space Parameters Kamin ERD 125 Kamin ERD 140 Kamin ERD 150 Kam...
Page 6: ...140 AF 140 139 285 510 460 300 50 9 8 Kamin ER 150 AF 150 149 285 510 460 300 50 9 8 Kamin ER 150 max AF 150 149 285 510 460 300 50 9 8 Kamin ER 160 AF 160 159 285 510 460 300 50 9 8 Type Extra option Dimensions mm Weight kg D B H H1 L P Kamin 125 KF 125 KF 125 GF 125 BY PASS 124 245 610 560 260 50 8 3 Kamin 140 KF 140 KF 140 GF 140 BY PASS 139 285 650 600 300 50 9 7 Kamin 150 KF 150 KF 150 GF 150...
Page 7: ...Decompression grille Air heating chamber in the fireplace hood Chimney furnace Cold air supply Warm air withdrawal from the fireplace hood Warm air Flame products 45 0 The fan starts when air temperature in the fireplace hood reaches the set point and distributes warm air from the chimney to other rooms The fan is turned off when air temperature drops down below the set point When air temperature ...
Page 8: ...r temperature in the fireplace hood reaches the set point the fan starts and distributes warm air from the chimney to other rooms and is turned off as temperature drops down below the set point The KFK mixing chamber provides cold air supply when the transported air temperature exceeds 90 C and hot air removal when the fan is off When air temperature in the fireplace hood reaches the set point the...
Page 9: ...an must be grounded The fan is designed for top or horizontal mounting depending on the model Install the fan on the even surface The fan mounting options are stated in fig 15 18 Provide free air circulation to cool down the fan motor For vibration attenuation it is recommended to install the fan on the rigid fire resistant support made of gypsum plate 0 5 x 0 5 m with mineral wool layer The minim...
Page 10: ...cuit when air temperature in the chimney reaches the set point The fan is started and supplies warm air to the room When the temperature in the chimney falls down below the set point the fan turns off Cut power supply to the fan off by turning the automatic electric switch QF to OFF position prior to any operations Take steps to prevent activation of the automatic switch Fig 19 1 2 3 4 X1 L N QF L...
Page 11: ... chimney Automatic switch tripping during the fan start Overcurrent as a result of short circuit in power mains leads to automatic switch tripping Turn the fan off Remove an overcurrent Check the automatic switch operability check automatic switch trip current Turn the automatic switch off on Restart the fan Low air flow Soiled filter Soiled diffusers grilles and air ducts Soiled impeller flange a...
Page 12: ...BLAUBERG KAMIN MANUFACTURE DATE SELLER SALES DATE REPRESENTATIVE IN EU Blauberg Ventilatoren GmbH Aidenbachstr 52a D 81379 München Germany WARRANTY CARD www blaubergventilatoren de Kamin v 3 5 EN ...