BLAUBERG Glory 100 Service Instructions Manual Download Page 1

EN

Lux

Glory

Service Instructions 

Summary of Contents for Glory 100

Page 1: ...EN Lux Glory Service Instructions ...

Page 2: ...uction contains a technical description technical data sheets operation and mounting guidelines safety precautions and warnings for safe and correct operation of the fans BLAUBERG Lux and Glory USE The fan is designed for exhaust ventilation of residential and public premises heated during winter season The fan is designed for wall mounting fig 3 5 COMPLETE SET fan 1 item screws and dowels 4 items...

Page 3: ... shown in tables 1 2 3 and in fig 1 and 2 The model without timer is shown in fig 1 Type Max air flow 3 m h Power W Noise level 3 m dBA 1 RPM min Lux Glory 100 14 2300 89 33 Lux Glory 125 16 2400 164 34 Lux Glory 150 24 2400 258 37 Fig 1 1 front panel for Lux polished stainless steel for Glory frosted glass 2 cover 3 LED light 4 decorative fitting piece 5 casing 6 electric motor 7 impeller 8 cover...

Page 4: ...urn off time range from 2 to 30 min Humidity sensor H humidity level range from 60 to 90 Type Lux Glory 100 Lux Glory 100 T Lux Glory 100 H Timer Humidity sensor Table 2 Lux Glory 125 Lux Glory 150 Lux 100 T H Glory 100 T H 183 120 153 6 98 67 a 181 b 120 c 148 d 100 98 e 56 65 0 65 0 7 0 85 0 85 0 9 1 15 231 165 161 150 56 1 05 1 65 140 120 154 151 6 125 56 183 204 ...

Page 5: ...ounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user s manual The single phase power grid must comply with the acting local electrical norms and standards The fixed electrical wiring must be equipped with an automatic switch that is used for connection...

Page 6: ...nt air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting The maximum permitted pressure difference per living units is 4 Pa Transported medium must not contain any dust or other solid impurities sticky substances or fibrous materials The fan is not rated for operation in a media that contains hazardous or explo...

Page 7: ... is designed for wall mounting to extract air into a ventilation shaft or matching air duct of respective diameter fig 3 5 The fan mounting sequence is shown in fig 6 The fan wiring diagrams are shown in fig 7 10 Fig 3 Fig 4 Fig 5 ...

Page 8: ...24 Fig 6 ...

Page 9: ...utomatic switch Fig 7 Fig 8 S QF S1 L N N L L S2 QF S L N N L L Fan does not run Switch is closed Light is off Fan runs Light is on S1 S2 S1 S2 Fan does not run Switch S1 and S2 are closed Light is off Switch S1 is closed switch S2 is opened Switch S2 is closed switch S1 is opened Fan runs Light is on Fan runs Light is off Fan does not run Light is on PE PE ...

Page 10: ...is closed Switch is opened Turn off delay timer starts 2 to 30 min LUX GLORY 100 T S external switch QF automatic switch S Fig 9 2min 30min T QF S L N SL N L Fan does not run Light is off Fan runs Light is on PE ...

Page 11: ...c switch Turn off delay timer starts 2 to 30 min Humidity is below set point Humidity exceeds set point Switch is closed Yes No Switch is opened Humidity is below set point Humidity exceeds set point Yes No Fan does not run Light is off Fan runs Light is on Fan runs Light is on Fan runs Light is on ...

Page 12: ...ustment operations The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments Use the screwdriver to adjust the turn off delay time or the humidity threshold Do not use a screwdriver knife etc for adjustment operations not to damage the circuit board 2min 30min T 60 90 H ...

Page 13: ...tation vehicle provided that the product is in the manufacturer s original package Store the delivered product in the manufacturer s original packing box in a dry ventilated premise with the ambient temperature from 5 C up to 40 C and relative humidity less than 80 The storage environment must be free of dust acid or alkali vapours to prevent corrosion DISPOSAL Do not dispose in domestic waste The...

Page 14: ...t of compliance of the product with the requirements relating to electromagnetic compatibility was based on the following standards Protection degree index according to IP rating against access to hazardous parts and water ingress IP24 The manufacturer hereby warrants normal operation of the fan over the period of five years from the retail sale date provided observance of the installation and ope...

Page 15: ...31 WARRANTY CARD ...

Page 16: ...MANUFACTURED ON DATE SALES DATE APPROVAL MARK SOLD model is recognized as serviceable 100 125 150 T H Lux Glory 3 4 1 2 5 6 LUX GLORY DE_EN ...