Centrifugal fan
USER'S MANUAL
EN
Centro
Page 1: ...Centrifugal fan USER S MANUAL EN Centro ...
Page 2: ...lation certificate 12 Warranty card 12 This user s manual is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle design and installation of the Centro unit and all its modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation ...
Page 3: ...ve environment containing spirits gasoline insecticides etc Do not close or block the intake or extract vents in order to ensure the efficient air flow Do not sit on the unit and do not put objects on it The information in this user s manual was correct at the time of the document s preparation The Company reserves the right to modify the technical characteristics design or configuration of its pr...
Page 4: ...ularly switched on and off by the utility Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances Ensure that the appliance is switched off from the supply mains before removing the guard WARNING If unusual oscillating movements is observed immediately stop using the appliance and contact the manufacturer its service agent ...
Page 5: ...stat and an external temperature sensor fixed on a 4 meter cable Power cable with mains plug Temperature based operation logic GT1 speed controller with an electronic thermostat and an external temperature sensor fixed on a 4 meter cable Power cable with mains plug Timer based operation logic GI1 speed controller with an electronic thermostat and an integrated temperature sensor Power cable with m...
Page 6: ...flow m3 h 642 1126 758 1268 RPM min 1 1940 2370 1870 2410 0Maximum transported air temperature C 25 60 Ingress protection rating IPX4 Parameter Centro 100 L Centro 100 Centro 125 L Centro 125 Centro 150 Voltage V 1 220 240 Frequency 50 60 50 60 50 60 50 60 50 60 Power W 62 63 80 81 61 64 79 81 80 84 Current A 0 38 0 38 0 34 0 34 0 38 0 4 0 34 0 35 0 35 0 37 Maximum air flow m3 h 205 210 250 290 26...
Page 7: ... fan switches to the maximum speed as the room air temperature exceeds the set point As the air temperature drops 2 C below the set point or if the initial temperature is below the set point the TSI goes out and the fan operates with the set speed Centro GT1 GTI1 The speed switching operations are more frequent as compared to the temperature based functioning logic G1 GI1 but one speed interval co...
Page 8: ...e fan is suitable both for horizontal or vertical mounting on the floor on the wall or on the ceiling Air motion in the system must be in compliance with the direction of the arrow on the fan casing Install a hood on the intake spigot side in case of vertical fan installation When installing the fan horizontally provide a straight air duct section at least 1 m long on the intake spigot side 9 1 m ...
Page 9: ...cuit in the event of overload or short circuit The position of the external automatic circuit breaker must ensure free access for quick power off of the unit The trip current of the automatic circuit breaker must exceed the maximum current consumption of the unit refer to the Technical data section or to the unit label The recommended trip current of the circuit breaker is the next current in the ...
Page 10: ...sharp blows scratches or rough handling during loading and unloading Prior to the initial power up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS ENSURE THAT THE UNIT IS SWITCHED OFF FROM THE SUPPLY MAINS BEFORE REMOVING THE GUARD TECHNICAL MAINTENANCE Clean t...
Page 11: ...e Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user s manual U...
Page 12: ...ATION CERTIFICATE The Centro__________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Installation Technician s Full Name Installation Date Signature The unit has been installed in accordance with the provisions of all the applicable local and national construction electrical and technical codes and standards ...
Page 13: ...www blaubergventilatoren de Centro 13 ...
Page 14: ...Centro 14 www blaubergventilatoren de ...
Page 15: ...www blaubergventilatoren de Centro 15 ...
Page 16: ...www blaubergventilatoren de B02EN 14 ...