BLAUBERG BLABAERO User Manual Download Page 1

USER’S MANUAL

BLABAERO

AXIAL WALL / CEILING FAN

EN  

Summary of Contents for BLABAERO

Page 1: ...USER S MANUAL BLABAERO AXIAL WALL CEILING FAN EN ...

Page 2: ...ting principle design and installation of the BLABAERO unit and all its modifications Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country The information in this user s manual is corr...

Page 3: ...lation and maintenance The present user s manual should be carefully read before beginning works Single phase power mains must comply with the acting local electrical norms and standards Fixed electrical wiring must be equipped with an automatic circuit breaker The unit must be connected to power mains through a QF automatic circuit breaker integrated into the fixed wiring system The gap between t...

Page 4: ...ombustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explosive...

Page 5: ...ldren should be supervised to ensure that they do not play with the appliance Ensure that the fan is switched off from the supply mains before removing the guard The fan is to be installed so that the blades are more than 2 1 m above the floor Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances THE PRODUCT MUST BE DISPO...

Page 6: ...ned for wall or ceiling mounting Fig 1 3 The fan is designed for connection to ø 100 125 and 150 mm air ducts OPERATION GUIDELINES The fan is rated for connection to single phase AC 220 240 V 50 Hz power mains Air motion direction in the system must match the pointer on the fan casing Hazardous parts access and water ingress protection rating is IP24 The fan is rated for operation at the ambient t...

Page 7: ... is designed for wall or ceiling mounting with direct air exhaust to the ventilation shaft or into the round air duct of matching diameter The fan mounting sequence is shown in fig 6 9 The fan wiring diagrams are shown in fig 10 1 2 3 ...

Page 8: ... to avoid unauthorized power supply connection Fig 11 Remove the decorative panels wipe the fan with a dry cloth or a brush Fig 12 Clean the front panel under running water Fig 13 Wipe the fan surfaces dry Cover the fan with the front panel Connect power supply to the fan Fig 14 WARNING Do not allow water or liquid come into contact with electric components ...

Page 9: ... be transported only in the working position Avoid sharp blows scratches or rough handling during loading and unloading Prior to the initial power up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING Problem Possible reasons Troubleshooting When the unit is connected to power mains the fan does not rotate and does not...

Page 10: ...iated with installation reinstallation or transporting the product Additional information Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement of the purchased product for a major failure of the product You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does...

Page 11: ... STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE FREE OPERATION OF THE UNIT USER S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT THE PAYMENT DOCUMENT AND THE USER S MANUAL WITH THE PURCHASE DATE STAMP ...

Page 12: ...12 EN 4 1 cover 2 timer 3 switch 4 casing 5 non return valve 1 2 5 4 3 ...

Page 13: ...13 EN 5 Model Dimensions mm Weight kg a b c d e BLABAERO 100 T 144 122 92 100 29 0 56 BLABAERO 125 168 144 97 125 30 0 73 BLABAERO 150 198 170 119 150 30 0 9 b d a c e ...

Page 14: ...14 EN 6 8 7 9 QF L N 6 ...

Page 15: ... S L N LT N L QF S L N LT N L Fan does not run Circuit breaker closing Fan runs Circuit breaker closing Turn off delay timer activation 2 30 minutes 2min 30min T TERMINAL DESIGNATIONS ONWIRING DIAGRAMS L phase 220 240 V only S external switch N neutral 220 240 V only QF automatic circuit breaker BLABAERO BLABAEROT ...

Page 16: ...16 EN QF L N 11 12 13 14 ...

Page 17: ...17 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date ...

Page 18: ...18 EN ...

Page 19: ...19 EN ...

Page 20: ...www blaubergventilation com au Blauberg_Australasia_Aero_EN 04 100 T Blauberg BLABAERO 125 150 ...