www.blaubergventilatoren.de
Solo a35/50/60 S4 Pro r (v.2)
7
READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT.
BEFORE INSTALLING ADDITIONAL EXTERNAL DEVICES,
READ THE RELEVANT USER MANUALS
DO NOT BLOCK THE AIR DUCT OF THE INSTALLED VENTILATOR WITH DUST
ACCUMULATING MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC.
AS IT PREVENTS AIR CIRCULATION IN THE ROOM.
To install an external ventilation hood or grille, it is necessary to have access to the outer wall surface at the installation site.
1. Prepare a round core hole in the outer wall. The hole diameter depends on the specific model of the ventilator and is indicated in the
table of overall dimensions in the “Technical data” section.
Ø D1
min 300
min 300
min 300
A
A
A-A
2. Install the air duct into the hole so that its cuts are aligned with the outside and inside surface of the wall.
For ease of installation use the foam wedges included in the delivery.
A
Fill the gaps between the wall
and the hole with a
mounting foam.
Foam wedge
min 3 mm
While mounting the air duct be sure to provide the minimum slope
of 3 mm downwards from outside.
The air duct can be cut by calculating preliminary the required length
or after fixing the air duct on the wall (in this case, it is necessary to
have access to the outside part of the wall).
MOUNTING AND SET-UP