CONTROL PANEL
OPERATION MANUAL
EN
S16
Page 1: ...CONTROL PANEL OPERATION MANUAL EN S16 ...
Page 2: ...ements as well as the provisions of all the applicable local and national construction electrical and technical norms and standards The warnings contained in the user s manual must be considered most seriously since they contain vital personal safety information Failure to follow the rules and safety precautions noted in this user s manual may result in an injury or unit damage After a careful rea...
Page 3: ...allation and maintenance operations with wet hands Do not wash the unit with water Protect the electric parts of the unit against ingress of water Do not allow children to operate the unit Disconnect the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or em...
Page 4: ...ES OR LACKING THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORIZED ACCESS BY UNATTENDED CHILDREN Control panel 1 piece User s Manual 1 piece Box 1 piece Parameter Value Ambient temperature C From 5 to 40 Relative humidity From 5 to 80 no condensation C...
Page 5: ...ble 0 25 mm2 in cross section The cable is pre wired to the air handling unit and the panel terminal block at the factory Make sure to memorize the positions and the colours of the wires connected to the terminal block to restore the original configuration upon re installing the panel The cable colours are given on the terminal block label Yellow B Green A Brown White 1 3 2 5 6 4 The mounting box ...
Page 6: ...on a subsequent power up of the unit and as a result incorrect scheduled operation To prevent this make sure that the battery is in good condition Use only fresh batteries for replacement 1 Disconnect the unit from power supply 2 Undo two self tapping screws in the bottom part of the casing 3 Pull the top part of the casing aside to facilitate access to the circuit board Replace the battery The co...
Page 7: ...perature sensor using the room air temperature sensor built into the control panel The main windows display the following information Window 1 see Fig 3 temperature regulation using the supply duct air temperature sensor a current temperature in the supply duct b pre set supply duct temperature value SETPOINT c current fan speed d current heater output e current operation mode of the air handling ...
Page 8: ...air temperature in the electric heater chamber The signal circuit includes normally closed contacts of thermal cut out switches installed in the electric heater chamber and the series connected control coil of the electromagnetic contactor used for emergency opening of the heater supply circuits This signal means that the air supply to the heater is insufficient Communication loss This signal is t...
Page 9: ...time On elapsing the air handling unit switches on automatically and continues to operate using the parameters in place before the temporary deactivation In this example upon the time selection and pressing the Enter button the air handling unit will switch off after heater cooling within 120 seconds and re activate in 90 minutes 2 Speed air capacity setup The user is prompted to select one of the...
Page 10: ...ly Unlike the daily timer the weekly schedule items trigger when the current time matches the programmed value not during the pre programmed period of time The user can set up to 15 programs for each day of the week Upon the weekly schedule activation the main window shows W Weekly schedule enabled in the Operation mode field Although the weekly schedule and the daily timer can be used simultaneou...
Page 11: ...e the following actions are set for Program 01 for MONDAY switch fan speed to stage 3 and set the control temperature to 23 C at 12 34 Press the Enter button to switch to Program 01 parameter editing window Use the Left Right buttons to select the parameter position and then use the Up Down buttons to set the parameter value In this example the cursor is currently at the clock field To set the tim...
Page 12: ... day of the week press the Left of Right button to move the cursor to the desired program number and select the program number to edit or delete by pressing the Up or Down buttons To proceed with editing press Enter to switch to the editing window Press Enter to delete the selected number program Upon deleting the cursor will return to the day of the week selection position the program will be del...
Page 13: ...d the air handling unit returns to the previous mode disabled or enabled and continue to follow the daily timer and weekly schedule program Format 1 enable 0 disable Default value 1 10 2 t heat exch freeze protect the outdoor air temperature threshold for engaging the heat exchanger freeze protection sequence which involves the bypass damper position adjustment while the bypass is in the automatic...
Page 14: ...ame with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the unit casing excluding external modifications as required for installation and internal components caused by the user Redesign or engineering changes to the unit Replacement and use of any assemblies parts and components not approved b...
Page 15: ...ctive 93 68 EEC on the approximation of the laws of the Member States relating to electromag netic compatibility which relate to electrical appliances used in set voltage classes This certificate is issued following test carried out on samples of the product referred to above Quality Inspector s Stamp Manufacture Date ____________________ Company Expert s Full Name Date Signature Control panel S16...
Page 16: ...www blaubergventilatoren de S16 v 1 1 EN ...