background image

www.blaubergventilatoren.de

Ceileo Compact DC 110 (light) H/ir

11

CONTROL

MICROPROCESSOR CONTROL UNIT WITH INDICATION

The operation of the fan with a DC motor is controlled by a microprocessor control unit. An indicator, control buttons and two connectors 
for connecting a humidity sensor and a motion sensor are located on the front panel of the control unit.

Indicator

Buttons

Humidity
sensor connector

Motion
sensor connector

After the fan is connected to power supply, the indicator displays 

 for two seconds. After that the light indicator goes off and the fan 

starts operating in set mode. Once the button 

  is pressed the indicator displays the turn-off delay timer setting 

, the first Setup 

menu entry. Use 

 or 

 buttons to navigate in the Setup menu. Press  ,  to select a current entry in the Setup menu. After that the 

indicator displays the selected parameter value (e.g., turn-off delay timer setting). Use 

 or 

 to change the value. Press 

 to come 

back to the Setup menu. If no button is pressed for 60 seconds, the indicator goes down.

Example

The indicator displays 

. Once the button    is pressed, the Setup menu list goes one position down and the symbol 

  is displayed 

(refer to the Setup menu). Once the button   is pressed, the indicator displays the turn-on delay timer setting, which can be edited with 
the buttons 

 and 

. Once the button 

  is pressed again, the Setup menu is displayed again and the edited value is saved.

To reset the menu to the factory settings, press and hold   and 

 synchronously. In 5 seconds the indicator displays 

, and goes off. 

The fan keeps running in a regular operation mode with the factory settings.

INDICATOR SYMBOLS OF THE MICROPROCESSOR CONTROL UNIT

 – turn-off delay timer adjustable from 1 to 90 minutes (default setting 15 minutes).
 – turn-on delay timer adjustable from 0 to 180 seconds with the increment of 10 seconds (default setting 0).

 – humidity setpoint adjustable from 50 % up to 90 % (default setting 75 %).
 – access to submenu of the fan operation mode.

Operation mode 

 – the fan operates without any activation signal from the switch, humidity or motion sensor.

Operation mode 

 – the fan operates with activation signal from the switch, humidity or motion sensor.

 – back to the upper setup menu level.

Once the switch is turned on or the humidity or motion sensor is activated, the fan switches from the mode 

 to the mode 

After a signal is no more received from the sensor in case of the indoor humidity normalization, or no more motion is detected in case of 
the fan shutdown, the fan keeps running for a set turn-off delay time and then switches from the mode 

 to the mode 

.

Summary of Contents for Ceileo Compact DC 110

Page 1: ...Centrifugal ceiling extract fan USER S MANUAL EN Ceileo Compact DC 110 Ceileo Compact DC 110 H IR Ceileo Compact DC 110 Light Ceileo Compact DC 110 Light H IR...

Page 2: ...s manual is correct at the time of the document s preparation The Company reserves the right to modify the technical characteristics design or configuration of its products at any time in order to inc...

Page 3: ...he entire service life of the unit While transferring the unit control the user s manual must be turned over to the receiving operator UNIT INSTALLATION AND OPERATION SAFETY PRECAUTIONS Disconnect the...

Page 4: ...ances in close proximity to the unit When the unit generates unusual sounds odour or emits smoke disconnect it from power supply and contact the Seller Do not open the unit during operation Do not dir...

Page 5: ...UT THE APPROPRIATE TRAINING THE UNIT MUST BE INSTALLED AND CONNECTED ONLY BY PROPERLY QUALIFIED PERSONNEL AFTER THE APPROPRIATE BRIEFING THE CHOICE OF UNIT INSTALLATION LOCATION MUST PREVENT UNAUTHORI...

Page 6: ...sign is constantly being improved thus some models may be slightly different from those described in this manual A E H d L2 L1 B L1 B C A E C b a h H d h L2 Ceileo Compact DC 110 Light Ceileo Compact...

Page 7: ...rative grille Surface mounted luminaire Lamps Casing Protective cap sensor panel Lamp connector Parameter Ceileo Compact DC 110 Ceileo Compact DC 110 H IR Ceileo Compact DC 110 Light Ceileo Compact DC...

Page 8: ...on and switches to high speed After no more motion is detected the fan keeps operating for a set turn off delay time period adjustable from 1 to 90 minutes and returns to its original state Humidity...

Page 9: ...lamp into the appropriate socket in the fan terminal box casing For models with the option of connecting H humidity or IR motion sensors remove the protective cap from the grille before installing the...

Page 10: ...FOR CONNECTING THE FAN TO POWER MAINS L2 L1 N L N LT N L N L QF 1 2 3 4 5 6 7 FAN 1 QF 100 240 V 50 60 Hz 100 240 V 50 60 Hz LIGHT the connector is only used in models with an LED module Remove the de...

Page 11: ...nce the button is pressed the indicator displays the turn on delay timer setting which can be edited with the buttons and Once the button is pressed again the Setup menu is displayed again and the edi...

Page 12: ...set and is the default setting for fans with a maximum air flow of 110 CFM For the fans with a maximum air flow 150 CFM Example 2 with these settings the fan will be constantly turned off Once the sw...

Page 13: ...the reverse order TROUBLESHOOTING TROUBLE POSSIBLE REASONS TROUBLESHOOTING The fan does not get started No power supply Check the electric connections and the operation status of the circuit breaker M...

Page 14: ...e suitable hoist machinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo The unit can be carri...

Page 15: ...l Contact the Seller for warranty service The manufacturer s warranty does not apply to the following cases User s failure to submit the unit with the entire delivery package as stated in the user s m...

Page 16: ...www blaubergventilatoren de Ceileo Compact DC 110 Light H IR 16...

Page 17: ...www blaubergventilatoren de Ceileo Compact DC 110 Light H IR 17...

Page 18: ...www blaubergventilatoren de Ceileo Compact DC 110 Light H IR 18...

Page 19: ...STALLATION CERTIFICATE The Ceileo Compact DC _____________ unit is installed pursuant to the requirements stated in the present user s manual Installation Stamp Company name Address Phone Number Insta...

Page 20: ...www blaubergventilatoren de B183EN 01...

Reviews: