EBE 350 VH
Operating Instructions
Fault diagnosis
Fault Possible
cause Remedy
Reduced or no
blasting
performance
Blast wheel or control
cage.
Adjustment of the shot
valve.
"Shocked blast wheel".
At the start of the blast
process too much
abrasive at once hits the
wheel.
The travel speed is too
high.
Worn blast wheel or
control cage, replace
worn parts if necessary.
Check the adjustment of
the valve.
Close the shot valve and
stop the blast wheel
motor. Start the blast
process again and slowly
open the valve.
Reduce the travel speed.
Escaping
abrasive
Poor sealing.
Check all seals and
replace if necessary.
Abrasive loss
on the surface
or escaping
abrasive at the
blast head
Poor abrasive quality.
Worn blast wheel parts.
Contact
ISPC
Blastrac/EBE
.
Replace worn blast
wheel parts.
Contaminated
abrasive
The filter unit is not
generating enough
suction power so that
dust remains in the
abrasive.
Check the filter unit
(cartridges and seals).
3
Summary of Contents for EBE 350 VH
Page 1: ...Operating Instructions EBE 350 VH MAN EBE 350VH EN...
Page 65: ...EBE 350 VH Operating Instructions Electrical systems Contents Chapter 8 8 1 Circuit diagrams 1...
Page 66: ...Operating Instructions EBE 350 VH Electrical systems 8 1 Circuit diagrams 2...
Page 88: ...EBE 350 VH Operating Instructions Spare parts Contents Chapter 10 10 1 Spare parts 1...
Page 90: ...EBE 350 VH Operating Instructions Spare parts Fig 10 1 3...
Page 93: ...Operating Instructions EBE 350 VH Spare parts Fig 10 3 6...
Page 95: ...Operating Instructions EBE 350 VH Spare parts Fig 10 4 8...
Page 98: ...EBE 350 VH Operating Instructions Spare parts Fig 10 6 11...