12
1.
Main power switch
The main power switch is located on the control box. It has to be switched OFF before connecting the machine
to the power supply. It has to be switched ON before operating the machine and the use of the extension lead.
2 - 3 - 4.
Control light, Buttons Compressor ON/OFF
Pressing the green button "ON" switches the compressor on, the control light shines. Pressing the red button
"OFF" switches the compressor off.
5.
Control light Motor protection
This light shines when the whole electric will be switched off due to an overload of one motor.
6 – 7 – 8.
Control light, Buttons Fan ON/OFF,
Pressing the green button switches the fan on, the control light shines. Pressing the red button switches the
fan off.
Phase inverter switch
This switch is located inside the control box. It is used when the phases of the power supply are incorrect.
Set the main power switch in position "0" and open the control box door. Now you can adjust the turning
direction of the motors with the phase inverter switch.
Pressure difference gauge
This gauge indicates the pressure difference between the clean and dirty side of the filters. Observe it to check
the status of the filters. Replace the filters when it indicates 15cm.H2O.
4.4
Transport
Please read chapter 3.7 “Transport safety”
Be careful! Make sure nobodies feet get under the wheels. Wear appropriate safety shoes when you drive the
machine to or from the work area.
Make sure that no vehicles, such as forklift trucks and other equipment run over the electric cable and the dust
hose.
The machine should only be moved around when the dust hose, and power supply cable are disconnected.
WARNING!
Always make sure all rotating parts have come to a complete standstill and there is no more
pressure in de air tank before moving the machine around.
Remove the dust from the dust collector before it is transported. The dust
collector may only be lifted by using the lifting points. The weight and