background image

User Manual & Datasheet 

 

BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx 

38 

HDC 6012 

 

Installation guide for F-connectors:  

/ Installationshinweis für den F-Anschluß: 

 

Elektronische Geräte gehören nicht in den Hausmüll, sondern müssen - gemäß Richtlinie 2002/96/EG 
DES EUROPÄISCHEN PARLAMENTS UND DES RATES vom 27. Januar 2003 über Elektro- und Elektronik-
Altgeräte fachgerecht entsorgt werden. 
Bitte geben Sie dieses Gerät am Ende seiner Verwendung zur Entsorgung an den dafür vorgesehenen 
öffentlichen Sammelstellen ab. 
 

Electronic equipment is not household waste - in accordance with directive 2002/96/EC OF THE 
EUROPEAN PARLIAMENT AND THE COUNCIL dated 27th January 2003 on used electrical and electronic 
equipment, it must be disposed of properly. 
At the end of its service life, take this unit for disposal to an appropriate official collection point 

 
Zur Beachtung / 

Important notes:  

 

 

 

Auf das Netzgerät dürfen keine mit Flüssigkeit gefüllten Gegenstände gestellt werden.  

 

No liquid-filled items may be placed on top of the power supply unit. 

 

Das Netzgerät darf nicht Tropf- oder Spritzwasser ausgesetzt sein. 

 

The power supply unit must not be exposed to dripping or splashing water. 

 

Der Netzstecker muss ohne Schwierigkeiten zugänglich und benutzbar sein. 

 

The mains plug must be easily accessible and operable. 

 

Das Gerät kann nur durch Ziehen des Netzsteckers vom Netz getrennt werden. 

 

The only reliable method of disconnecting the unit from the mains is to unplug it. 

 

Bei  größerem  Durchmesser  des  Kabel-  Innenleiters  als  1,2  mm  bzw.  Grat  können  die 
Gerätebuchsen zerstört werden. 

 

If the inner cable conductor diameter is greater than 1.2 mm or in case of burr, the device sockets 
may be destroyed. 

 

 

 

 

Bitte installieren Sie die Anschlüsse gemäß  dem Aufdruck  

Please install according to the sticker on the Multiswitch 

Hinweis: Elektrische Installationen sollten nur durch geschultes Fachpersonal vorgenommen werden! 

Note: Electrical installations should only be done by well-educated and skilled technicians! 

 

Die LNB-Anschlüsse sind meist entsprechend 
gekennzeichnet 

The LNC 

connectors at Multiswitches are 

almost marked as: 

HH= Horizontal High-Band 

HL = Horizontal Low-Band = LH 

VL = Vertical Low-Band = LV 

VH= Vertical High-Band = HV 

 

 

Summary of Contents for HDC 6012

Page 1: ...Web management Updates via web DiSEqC 1 0 LNB control for up to 4 satellite positions Dual power supply optional The BLANKOM HDC 6012 is a high performance and cost effective QAM Transmodulator It has...

Page 2: ...Streams 10 Network Information Table 14 Adjusting RF QAM output 15 BISS decryption 18 Conditional Access encryption 20 Multiplexer 20 Network Settings 24 Configuration Backup Restore 24 Firmware upgra...

Page 3: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 3 HDC 6012...

Page 4: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 4 HDC 6012 Application Example...

Page 5: ...gth 65 25dBm Supports QPSK 8PSK supports DiSEqC 1 0 LNB control for up to 4 satellite positions BISS descrambling capable Multiplexing 4 multiplexers Maximum PID remapping 128per input channel PID rem...

Page 6: ...dress is 192 168 0 136 We recommend to use the latest Firefox Browser User password is per default admin admin and you end up in the Status window Setting up NTP Server for i e Europe Usually the unit...

Page 7: ...cessary for the first time setup of this transmodulator So first chose your region than try to get some NTP Server addresses from the internet like Or use Setting up Tuner Inputs Of course L Band as w...

Page 8: ...C 6012_Manual_EN RR 06 2021_V1 5 docx 8 HDC 6012 Enter the values 10741 25 as frequency Horizontal 18V ON Symbolrate 22000 SAT pos 1 depending on your Multiswitch LOW Band 22KHz off FEC will be detect...

Page 9: ...nput must use the same SAT position polarisation band as the first one by avoiding different polarisations H V and low High Band must be equal Setting up a second transponder from SAT POS 2 here Hotbi...

Page 10: ...witched on Finally we have all tuners configured and running Setting up incoming IP Streams We have some streams connected to the same switch from another source as MPTS and some as SPTS so we need to...

Page 11: ...n see all tuner inputs even with bitrates received but no content yet First we have already added a SPTS from 239 42 22 1 Multicast address as UDP with port number 1234 So we add an MPTS coming as Mul...

Page 12: ...6012 Now we need to parse each tuner and IP stream content to the machine or parse step by step each marked Tuner1 12 and IP streams Parse select all SPTS already assigns the SPTS to the output Here...

Page 13: ...Service was scrambled somehow decrypted i e coming as MPTS or SPTS and containing still CA Flags and maybe EMM ECM PIDs which are filktered out by this CA Filter becasue the output mux should not reco...

Page 14: ...elect the output frequencies and values for the QAM channels high bandwidth can be reached by i e 256 QAM Srate 6950 low FEC you can add all other channels from your network here to generate a common...

Page 15: ...rt is now the right time So we adjust the own DVB C RF channels here Because the channels are adjacent 4x 8 MHz and we don t use the american Annex B standard ITU we get the overall settings as The SP...

Page 16: ...012 PID remapping is recommended to avoid collisions To avoid an Overflow you should always consider an overhead of 10 15 because the peaks would disturb all services in the bouquet which isn t that n...

Page 17: ...2021_V1 5 docx 17 HDC 6012 So better to get rid of one of them Thats not enough so we delete a 2nd one Thats much better To get the full information just click on a service And you can manipulate eve...

Page 18: ...atasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 18 HDC 6012 BISS decryption You can descramble a selected service by a BISS key which you need to configure before in the BISS section Than sel...

Page 19: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 19 HDC 6012 It will be shown now and selectable in the Programm Information...

Page 20: ...012 Conditional Access encryption The already configured output multiplexes can be simul encrypted by up to 4 different CA Systems The configuration is nearly self explaining Multiplexer Back to the M...

Page 21: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 21 HDC 6012 with the PID Bypass you can pass individual PIDs from the Inputs to the outputs...

Page 22: ...he content and assign it to the Output with CA Filter and PID remapping The CA components are filtered out and the PIDs are remapped After finally all QAM Outputs are configured maybe write a new NIT...

Page 23: ...atasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 23 HDC 6012 Each of them can be configured as scrambled if CAS is setup or even as unscrambled you can set it as VBR null paket filter enables...

Page 24: ...06 2021_V1 5 docx 24 HDC 6012 Network Settings Scrambler and NMS are on the same Ethernet RJ45 port with 100BaseT while the DATA port has GbE NMS and scrambler communication port IP addresses can be c...

Page 25: ...BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 25 HDC 6012 Save will internally save your config but we recommend to backup the file to your computer Restoring works vice versa Firmware upgrade is n...

Page 26: ...User Manual Datasheet BLANKOM HDC 6012_Manual_EN RR 06 2021_V1 5 docx 26 HDC 6012...

Page 27: ...6 2021_V1 5 docx 27 HDC 6012 Logs should be sent to us in case of support issues Please note Remultiplexing would destroy EPG data from the original source This cost effective Receiver multiplexer scr...

Page 28: ...this publication and make changes in its content from time to time whereby it shall not be obligatory for IRENIS GmbH to provide notification of such revision or change IRENIS GmbH provides this manua...

Page 29: ...administrative scope sessions using administratively scoped IP multicast The multicast address to be used for announcements is the highest multicast address in the relevant administrative scope zone...

Page 30: ...230 237 233 50 231 25 236 75 40 630 638 634 00 631 25 636 75 S 12 237 244 240 50 238 25 243 75 41 638 646 642 00 639 25 644 75 S 13 244 251 247 50 245 25 250 75 42 646 654 650 00 647 25 652 75 S 14 2...

Page 31: ...6 31 5 3E 04 17 77 31 75 7 08 6 7E 04 18 78 30 75 7 94 8 4E 04 19 79 29 75 8 91 1 1E 03 20 80 28 75 10 00 1 3E 03 21 81 27 75 11 22 1 7E 03 22 82 26 75 12 59 2 1E 03 23 83 25 75 14 13 2 7E 03 24 84 24...

Page 32: ...841 49 109 0 25 281 84 1 059 50 110 1 25 316 23 1 333 51 111 2 25 354 81 1 679 52 112 3 25 398 11 2 113 53 113 4 25 446 68 2 660 54 114 5 25 501 19 3 349 55 115 6 25 562 34 4 216 56 116 7 25 630 96 5...

Page 33: ...timmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce...

Page 34: ...be damaged or crushed by any objects Furthermore ensure that cables are not laid in the immediate vicinity of sources of heat e g radiators other electrical devices fireplaces etc Risk of fire risk o...

Page 35: ...and operated when the mains adaptor cover is installed This also applies when you clean the device or work on the connections Danger Repairs on the device may only be carried out by a specialist see...

Page 36: ...egenst nde besch digt oder gequetscht werden Es ist dar ber hinaus unbedingt darauf zu achten da Kabel nicht in die direkte N he von W rmequellen verlegt werden z B Heizk rper andere Elektroger te Kam...

Page 37: ...mit montierter Netzteilabdeckung an Spannung angeschlossen und betrieben werden Dies gilt auch wenn Sie das Ger t reinigen oder an den Anschl ssen arbeiten Gefahr Reparaturen am Ger t sind ausschlie...

Page 38: ...p of the power supply unit Das Netzger t darf nicht Tropf oder Spritzwasser ausgesetzt sein The power supply unit must not be exposed to dripping or splashing water Der Netzstecker muss ohne Schwierig...

Page 39: ...tact IRENIS GmbH Hauptstr 29 31171 Nordstemmen Germany Phone 49 5069 4809781 IRENIS technical hotline VoIP 49 5069 4399 860 or 8601 Managing Director Dipl Ing Murad nol Commercial Register HRB 206370...

Reviews: