Smart Servo Electronic Valve Handbuch
Page 1: ...Smart Servo Electronic Valve Handbuch ...
Page 2: ... right to change the information contained in this manual without any notice Every precaution has been taken in the preparation of this manual Nevertheless Blain Hydraulics assumes no responsibility for damages resulting from the misuse of the information contained in this publication For support please contact Technical support Sales Pfaffenstrasse 1 74078 Heilbronn Germany Tel 49 7131 282132 Fax...
Page 3: ...1 Ventilerläuterungen 10 4 Eletrische Installation 12 5 Ventileinstellungen 13 6 Durchfluß Sensor und Magnetventileinstellung 14 7 WLAN Verbindungen Sicherheit 16 8 Installation 17 8 1 Menüstruktur der Software 17 8 2 Hauptmenü 18 8 3 Update 26 9 Fehler 27 10 Monitoring 28 11 Auswahldiagramme Einsatzgrößen 30 12 Troubleshooting 31 12 1 Allgemeine Fehler 31 12 2 Hubfahrt 32 12 3 Senkfahrt 33 13 Dur...
Page 4: ...even see the travel graphs of the elevator The platform is system independent and can be accessed using any standard web browser independent of the operating system of the device used for interacting with the card The Wi Fi connectivity makes it very easy to use any smart device for set up fine tuning and real time monitoring from a distance without the hassle of using different cables and compati...
Page 5: ...relais Ausgang D Seriennummer Karte auf Rückseite L Versorgungsspannung 24 V DC 18 V AC E Durchfluss Sensoreinstellung M Fehler LED rot Warnungs LED orange F Temperatursensor Anschluß N Power LED grün G Drucksensor Anschluß O Bestätigungs oder OK Button H Durchfluss Anschluß P Platz für Erweiterungsplatine Blain 000000 SEV07 0000 C O L K A B E D F G H I J M N P ...
Page 6: ...flash slowly If an update is being processed the green LED will flash rapidly until the update is finished Green Red STATE LED The orange state LED flashes slowly Any other behaviour is related to communication problems and reflects a defect Durchfluss LEDs Diese LED zeigen an ob der Sensor richtig justiert wurde Wenn er zu hoch oder zu tief eingestellt wurde wird dies durch die beiden orangenen L...
Page 7: ...e and shut off cock 100 continuous duty solenoids Self closing manual lowering Technische Daten 1 SEV 1 SEV 2 SEV Durchfluss Bereich l min USgpm 40 180 10 48 430 114 580 153 Druckbereich bar psi 9 70 130 1000 Platzdruck bar psi 400 5750 Druckverlust static bar psi 2 3 bar 29 44 psi abhängig vom Druchfluss und der Anschlussgröße Gewicht kg lbs 10 22 Ölviskosität 22 75 cSt at 40 C 104 F Max Öltemper...
Page 8: ...chalter KS Schlaffseilverhinderung BV Kugelhahn HP Handpumpe Figure 4 Hydraulikschema Steuerelemente Senkeinstellungen C Magnetventil Senkfahrt U Umlaufkolben 7 Begrenzung max Senkgeschw D Magnetventil Hauptsenkfreigabe V Rückschlagnemtil 9 Notablass Geschwindigkeit H Notablaß X Senkkolben S Überdruckventil Y Senk Schleichfahrtventil 1 SEV 1 SEV 2 SEV ...
Page 9: ...alve R Flow ring 2 Pilot orifice Up F Filter S Pressure relief valve 8 Pilot orifice Down H Manual lowering U Bypass valve R E Horizontaler Schnitt Senkrechter Schnitt Z 8 2 X V U Y CT AT D C A 8 2 S H F XC UC Figure 5 Schnittansicht SEV Ventil Zylinder Anschlüsse P Pumpe T Tank Z Zylinder Pilotdruck Kammern UC Umlaufkammer XC Senkventilkammer Einstellung AUF AT Hubtrim Seite 13 Einstellung AB CT ...
Page 10: ...ection of the measured flow to target flow values continue throughout the complete Up operation of the elevator Sebkfahrt Achtung Die Spannungsversorgung für die D Spule erfolgt direct vom Schaltschrank nicht von der SEV Karte 6 With a Down signal coil D is energized solenoid D normally closed opens and the electronic card s Down program starts simultaneously 7 Coil C is energized from the card an...
Page 11: ...l lowering H for an instant to release pressure inside the valve Wichtig Wenn das Überdruckventil getestet wird den Kugelhahn nicht schlagartig schließen KS Slack rope valve Coils C and D must be de energized The KS is adjusted with a 3 mm Allen key Turning the screw K in results in a higher pressure setting and out in a lower pressure setting To adjust turn K all the way in then turn K out until ...
Page 12: ...sorgung Eingangssignale 11 Ausgangsspannung Senkspule C 12 Ausgangsspannung Hubspule A 13 Gemeinsame Masse für Hub und Senkspule 16 Fehlerrelais NC geschlossen wenn OK 17 Fehlerrelais COM 18 Fehlerrelais NO offen wenn OK 19 Versogungsspannung Masse 20 Versogungsspannung 18V AC 24V DC 21 Temperatursensor C weiß 22 Temperatursensor B grau 23 Temperatursensor A grün 24 Drucksensor Versorgung 24 V rot...
Page 13: ...ator controller The power to coils A and C is supplied from the card Power to coil D is directly provided by the main controller Page 11 shows the detailed wiring diagram for connecting the SEV card to the elevator controller Installation of Deceleration Switches in the Elevator Shaft Als Schachtschalter Abstände für die Abbremsung und der Halt empfehlen wir die Werte aus folgender Tabelle Empfohl...
Page 14: ...mit Schleichfahrt da hier mehr Zeit zum Einstellen ist Zum Ändern des Werts ist die Einstellschraube rein oder heraus zu drehen Mittels reindrehen erhöht sich der Digitalwert herausdrehen verringert den Digitalwert Einstellen des Durchflußsensors Achtung Der Durchflußsensor ist bereits werksseitig eingestellt Eine Neueinstellung ist nur nach Tausch des Sensors notwendig Vertikale Sensor Einstellun...
Page 15: ...eveling speed is slower than Up leveling speed rotate the bushing 2 clockwise by 15 and re measure the leveling speeds If Down leveling speed is faster than Up leveling speed rotate the bushing 2 counter clockwise by 15 and re measure the leveling speeds Repeat the process of rotating the bushing in clockwise or anti clockwise as required to set the Up and Down leveling speeds to be practically th...
Page 16: ...Datenaufzeichnung Um die SEV Karte mit Ihrem Smart Gerät zu verbinden stellen Sie sicher dass der DIP 1 auf Position ON steht Die Blaue LED blinkt wenn WLAN eingeschalten ist Sobald eine Verbindung besteht leuchte die blaue LED Verbindung aufbauen 1 2 3 4 Das BLAIN SEV WLAN auswählen Anmelden mit dem Passwort Das voreingestelle Passwort lautet 12345678 Nach dem Verbindungsaufbau auf WLAN drücken u...
Page 17: ...2 Meldungen 3 Update Installationsassistent 1 Start Seite Einleitung 2 Zylinder Daten Übersetzung Anzahl der Zylinder Zylinderinders Zyl Type Durchmesser 3 Pumpendaten Leistung Wirkungsgrad 4 Gewicht Druck Leere Kabine Zuladung Min Druck Max Druck 5 Daten Hubfahrt Vollfahrt Beschleunigung Weichhalt 6 Daten Senkfahrt Vollfahrt Beschleunigung 7 Daten Inspektionsfahrt Hub Geschwindigkeit Senk Geschwi...
Page 18: ...software The most important points of navigating the menu will be covered and the sub menus Install wizard Data collection Settings and State Notifications will be explained in detail As the software for interacting with the SEV card resides on the webserver and on the card itself no additional software installation on the smart device is necessary This unique feature allows the user to use any sm...
Page 19: ...nd flow are displayed In case of no readings the connections need to be rechecked or the sensors changed LEDs for input and output give feedback for diagnostics While traveling constantly in full speed or levelling speed in Up or Down direction the highlighted digital value should stay in the range of 2100 200 The green check marks should show up behind the digital values of the solenoids giving f...
Page 20: ...y the values for minimum and maximum pressure can be entered Please note that entering the weight would automatically calculate the pressure and vice versa Links und Rechts Eingabe der gewünschten Geschwindigkeit Beschleunigung und Abbremsungszeiten für die Hub und Senkfahrt Die Vollfahrt in Hubrichtung ist bereits anhand der eingegebenen Zylinder und Pumpendaten berechnet Die Geschwindigkeit in S...
Page 21: ...hanges can be made in the Data collection sub menu as well Links Im Menüpunkt Datensammlung werden in verschiedenen Untermenüs die eingestellten Daten der SEV Karte zum Editieren angezeigt Die Daten können durch anklicken von Aufzugsdaten oder Fahrdaten geändert werden Zusätzlich ist hier der Zugang zur Funktion Lernfahrt zum Log buch sowie zur Problembeheb ung Die Lernfahrt kalibriert den Durchfl...
Page 22: ...hventil Test durchzu führen wählen den Button R10 Test aus Links Eine Warnung erscheint wenn der Zugangang zum Rohrbruchventil Test eingeleitet wird Nach der Bestätigung erfolgt eine kurze Einweisung ehe der rechte Bildschirm angezeigt wird Dieser Test sollte nur von geschultem Fachpersonal durchgeführt werden Rechts Zum Testen des Rohrbruchventils schrittweise den Anweisungen folgen Aus Sicherhei...
Page 23: ...weise zu allgemeinen Fehler sowie zu Fehler während der Hub und Senkfahrt gegeben Diese können auch auf der home page www blain de eingesehen werden Left Looking at the travel graph section there are three different views to choose from Travel graphs give the customer and the Blain Hydraulics tech support the possibility to run system diagnostics and check for possible problems On the left there a...
Page 24: ...runs error runs and operating hours In case of errors they will be displayed in the error message section Once corrected the errors can be reset Left Within the settings you can change the date and time set the units between SI and Imperial and access the Settings sub menus Rechts Dieser Bereich gibt die Möglichkeit die Fahreigenschaften zu verbessern die u a durch die Verwendung falscher Einsätze...
Page 25: ...ort für die aktuelle Verbindung und die IP Adresse Während die IP Adresse fest eingestellt ist kann die SSID und das Passwort frei gewählt werden So lässt sich ein Fremdeingriff wirksam unterbinden Right The Pro menu is reserved for OEM s and Blain Hydraulics since this menu section allows to save entered data as factory settings and change sensor values OEMs are allowed to save settings as factor...
Page 26: ...d normally take 1 2 min Alternatively the software can be updated by pressing the update button in the status menu without disconnecting the power supply The micro SD card and the jumper need to be set as well The jumper should be set to non bridged mode once the update process has been completed Step by step guide 1 Disconnect the electronic card from the power supply 2 Set the jumper to bridge t...
Page 27: ... vom Durchfluß D Spule oder Pumpe prüfen 5 Sensorüberlauf Der Sensorwert hat einen zulässigen Wert überschritten Sensor justieren 6 zu lange Schleicht Fahrzeit in Schleichfahrt Hub oder Senkrichtung war zu lang Schachtschalter prüfen 7 Etage überfahren Aufzug hat die Etage überfahren Schachtschalter prüfen Die Fehler 3 bis 7 haben keinen Einfluss auf die Funktion des Aufzugs Solange die Versorgung...
Page 28: ...sicht 1 ist die gebräuchlichste und wird vom Anwender und Blain Hydraulics genutzt um die Fahreingenschaften des Aufzugs zu anylysieren Angezeigt werden die Soll und Ist Geschwindigkeit für Hub und Senkfahrt die Leistung der Magnetspulen und die Beschleunigungswerte Siehe Beispiel Ansicht 2 zeigt die Werte des PID Reglers und wird hauptsächlich durch den Technischen Support von Blain Hydraulics zu...
Page 29: ... wechselt dies zum Lupensymbol Mit Auswahl der Lupenfunktion bekommen die Pfeiltasten eine neue Funktion Reinzoomen linker Pfeil Rauszoomen rechter Pfeil Mit Schaltfläche 7 lassen sich die verschiedenen Kanäle auswählen Dies gehrt in jeder Ansicht Die Farbe der Fahrkurve rot oder grün zeigt an ob die Fahrt eine Hub oder Senkfahrt war Ansicht 1 Bsp für Hubfahrt Sollkurve Ist Geschwindigkeit Hub Ist...
Page 30: ...raise car manually DH Pressure Switches Signals hydraulic pressure above the normal operating pressure DL Pressure Switches Signals hydraulic pressure below the normal operating pressure Flow ring R selection l min US gpm Ring size P T Z ports 40 75 10 20 R1 1 G 76 110 21 29 R2 1 G 111 180 30 47 R3 1 G 181 270 47 70 R4 1 5 G 271 430 71 112 R5 1 5 G 431 580 112 151 R6 2 G 581 1200 152 312 R7 2 5 G ...
Page 31: ...controller signaling Simultaneous Up and DOWN signal input on SEV card Check signal input and only give a signal for one direction 3 Elevator always passes the floor level Elevator is travelling faster than set speed Sensor is not correctly adjusted Adjust sensor correctly Look at sensor adjustment in SEV manual 4 Can t adjust the flow sensor to standard settings Sensor is faulty Change sensor Bro...
Page 32: ...n on the guide rails or in the cylinder head Cannot be eliminated through valve adjustment 3 No deceleration into leveling speed O Ring UO on bypass flow guide U is leaking Change O Ring look at SEV spare parts list Deceleration time target value too high Set lower value for deceleration time 2 5 s 4 Deceleration into leveling speed but overtravel of floor level Deceleration time target value too ...
Page 33: ...ing SEV spare parts list O Ring VO of check valve V leaking Change O Ring SEV spare parts list O Ring WO of check valve V leaking Change O Ring SEV spare parts list Inner O Ring FO in flange 4F leaking Change O Ring SEV spare parts list O Ring HO of manual lowering H leaking Change O Ring HO or change manual lowering Short delay valve E is leaking Change short delay valve 6 Deviation of target tre...
Page 34: ...SEV User Manual Version 07 2020 34 13 DURCHFLUß ZU GESCHWINDIGKEIT DRUCK ZU GEWICHT ...
Page 35: ...SEV User Manual Version 07 2020 35 ...
Page 36: ...SEV User Manual Version 07 2020 36 ...
Page 37: ......