Blain Hydraulics R10 Instruction Manual Download Page 1

GmbH

A

A

Z

T

aG

30

l

m

DK

o

a

n

p

a

G¼"

B

bG

b

D

E

Ød

Øe

dM

eM

d

e

ØV

F

V

f1

v

f2

fM

f3

F

R10 ½"

DK
G¹⁄ "

8

R 10 AA Standard 

R 10 AA + Option (DK + ES)

R 10L AA

R 10L-R

R10

Examples •

5-2100 l/min

1,3-546 US gpm

5-2100 l/min

1,3-546 US gpm

B

Z

D

¾"- 3"

E

R10

D

D

E

EV100

T

B

F

0

Z

F

¾" - 3"

F

R10

F

0

F

0

F

EV100

T

E

 Adaptor BE

Inch - mm

B - E

  ¾" - M36x2
 

1" - M36x2

  1½" - M36x2
 

1" - M52x2

  1½" - M52x2
 

2" - M52x2

  1½" - M65x2
 

2" - M65x2

 

2" - M78x2

  2½" - M78x2

B

E

Pipe or hose

ES

Any connections 90°

L

R10L

in

V

G o.

NPT

M

52 x 2

 Ød

  

d

 Øe

  

e

 28

   26

M

52 x 2

M

36 x 2

M

36 x 2

M

52 x 2

M

65 x 2

M

52 x 2

 42

   44

 28

   26

 42

   44

 42

   26

 42

   44

 56

   40

 56

   44

kg

 63

   50

 63

   40

M

78 x 2

M

65 x 2

M

78 x 2

d

 63

   50

M

78 x 2

 63

   40

M

78 x 2

 

Recommended size • 

1,05

26,7

38

1,5

1,5

1,5

1,5

1,5

1,5

38

38

38

38

38

1,31

1,90

2,37

2,87

3,50

33,4

48,3

60,3

73,0

88,9

ØV

in

ØV

mm

V

mm

90° 

Optional

I/min

US gpm

bar

EN81

psi

CSA

G o.

NPT

a

b

dM

eM

DN fM

f1

f2

f3

5 - 100

50 - 175

100 - 425

250 - 800

700 - 1250

1200 - 2100

1,3 - 26

13 - 46

26 - 112

66 - 211

185 - 330

317 - 554

100

100

100

80

60

1150

1150

1350

950

880

690

¾''

1''

1½''

2''

2½''

3''

¾''

1''

1½''

2''

2½''

3''

18

21

26

28

30

34

32

35

38

45

45

32

19

25

38

51

64

76

M 10

M 10

M 12

M 12

M 12

M 16

36

38

44

45

50

50

47,6

52,4

70

77,8

89

106,4

22,2

26,2

35,7

42,9

50,8

62

105

105

143

167

196

240

62

62

94

108

121

149

50

50

60

80

100

120

11

11

11

20

19

22

11

11

11

17

18

21

(AA)

6

6

8

8

10

1,6

1,6

3,4

7

13

21

 

R10 

R10  A  B  L 

V       

DK

 Qc  P 

max

      

 

 

SAE

 Victaulic 

l  m  n  o p 

Tube

4 - 90

1,0 - 23,8

100
100

1350 ½'' 18

88

53

40

9

11

6

0,9

6

Blain Hydraulics GmbH  Tel. +49 7131 28210
Pfaffenstrasse 1 

Fax +49 7131 282199

74078 Heilbronn 

www.blain.de

Germany info

@

blain.de

Designer and Manufacturer of the highest 
quality control valves 

&

 safety components

for hydraulic elevators

DK

EN ISO 9001

  

 

The rupture valve 

R10

 can be 

mounted in any position directly 
onto the cylinder inlet connec-
tion 

Z

. The '

T

' port is connected to 

the Tank. Fitted incorrectly the R10 
valve will not function. The cylinder 
side of the R10 can be identified by 
locating a small orifice behind the 
inside screw thread.

In the event of failure in the main 
cylinder line or where the down 
speed exceeds allowable limits, the 
R10 valve closes, bringing the car 
to a smooth stop.

GB

Warning:

 Only qualified personnel should service hydraulic valves. 

Unauthorised manipulation may result in injury or damage to equip-
ment. Prior to servicing internal parts, ensure that the electrical power 
is switched off and residual pressure in the system is reduced to zero.

Elevator Rupture Valve

Instruction Manual

 

Alternative connections •

Optional

R 10L-R

R 10L-L

Z

T

Z

T

Das Rohrbruchventil 

R10

 wird direkt 

am Zylinder montiert. Es ist sicher-
zustellen, dass die mit 

Z

 markierte 

Seite zum Zylinder, hier befindet 
sich eine eingeschraubte Düse im 
Anschluss, und die mit 

T

 zum Tank 

zeigt. Ein falscher Einbau verhindert 
das Schließen des R10. Eine Einbau-
lage ist nicht zu beachten.

Sinkt der Aufzug wegen eines Rohr-
bruchs in der Zylinderleitung oder 
sonstiger Übergeschwindigkeit ab, 
wird der Aufzug vom R10 durch ge-
dämpftes Schließen zum Stillstand 
gebracht.

Warnung:

 Verletzungsgefahr! Neueinstellungen und Wartung dürfen nur 

durch qualifiziertes Aufzugspersonal durchgeführt werden. Vor der War-
tung innerer Teile ist sicherzustellen, dass der elektrische Strom des Auf-
zuges abgeschaltet und der Druck im Ventil auf null reduziert worden ist.

Aufzugs-Rohrbruchventil

Betriebsanleitung

 

 

Empfohlene Größe 

Rohr oder Schlauch

Jeder Anschluss 90°

 Beispiele

 

 

 Alternative Anschlüsse

D

Reviews: