BLACKMER SEAL-LESS PUMPS
960902
INSTRUCTIONS NO. 108-B00
_apr05
INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS
MODELS:
SMVP50B, SMVP100B, SMVP200B
Section
Effective
Replaces
108
April 2005
July 2002
TABLE OF CONTENTS
Page
PUMP DATA
Technical
Data....................................................... 2
Initial Pump Start Up Information........................... 2
INSTALLATION
Pre-Installation
Cleaning........................................ 3
Location and Piping ............................................... 3
Check
Valves......................................................... 3
Pump
Mounting...................................................... 3
Motor
Installation ................................................... 4
OPERATION
Pre-Start Up Check List ......................................... 5
Start Up Procedures .............................................. 5
Pump
Rotation ....................................................... 5
Reverse
Rotation ................................................... 5
Flushing the Pump................................................. 5
Pump Relief Valve ................................................. 6
Relief Valve Setting and Adjustment ..................... 6
MAINTENANCE
Strainers ................................................................ 7
Lubrication ............................................................. 7
Vane
Replacement ................................................ 8
Pump
Disassembly ................................................ 8
Pump
Assembly..................................................... 9
TROUBLE SHOOTING
......................................
11
NOTE
: Numbers in parentheses following individual parts
indicate reference numbers on Blackmer Parts Lists 108-
B01, 108-B02 and 108-B03.
NOTE
: Blackmer pump manuals & parts lists may be
obtained from Blackmer’s website (www. blackmer. com)
or by contacting Blackmer Customer Service
SAFETY DATA
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the product, or in the
manual, look for one of the following signal words and be
alert to the potential for personal injury, death or major
property damage
Warns of hazards that WILL cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury
or property damage.
NOTICE:
Indicates special instructions which are very
important and must be followed.
NOTICE:
Blackmer Seal-Less pumps
MUST
only be installed In
systems, which have been designed by qualified
engineering personnel. The system
MUST
conform to
all applicable local and national regulations and safety
standards.
This manual is intended to assist in the installation
and operation of the Blackmer Seal-Less pumps, and
MUST
be kept with the pump.
Blackmer Seal-Less pump service shall be performed
by qualified technicians
ONLY
. Service shall conform
to all applicable local and national regulations and
safety standards.
Thoroughly review this manual, all instructions and
hazard warnings,
BEFORE
performing any work on
the Blackmer Seal-Less pumps.
Maintain
ALL
system and Blackmer Seal-Less pump
operation and hazard warning decals.
2007:
Discontinued Models: MVP50B, MVP100B, SMVP300B