background image

Works with an optical laser source to test optical 

fiber cables for optical loss.

Works at six wavelengths: 850, 1300, 1310, 1490, 1550, and 1625 nm. 

Optical Power Meter, Basic

Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) •
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax  
724-746-0746 • www.blackbox.com   •   [email protected]

Customer 

Support 

Information

FOPM-100 
FOPM-150

Summary of Contents for FOPM-100

Page 1: ...50 1300 1310 1490 1550 and 1625 nm Optical Power Meter Basic Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746...

Page 2: ...ld void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio Interference Regul...

Page 3: ...es de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato el ctrico deber ser connectado a una fuente de poder s lo del tipo de...

Page 4: ...ndo A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar n...

Page 5: ...ic shock or equipment damage Connect the AC power cord to the equipment and wall socket properly When you insert the AC plug make sure there is no dust or dirt on the terminals and both plugs are full...

Page 6: ...Used in this Manual TRADEMARKS USED IN THIS MANUAL Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged...

Page 7: ...and Controls 13 4 1 1 Keypad 13 4 1 2 Connectors 14 4 1 3 LCD 14 4 2 Turning the Optical Power Meter On and Off 15 4 3 Setting the Wavelength 16 4 4 Setting and Checking the Reference Level 16 4 5 Sw...

Page 8: ...0 1490 1550 1625 Connectors FC PC SC PC and ST PC interchangeable connectors optional Detector Type InGaAs Accuracy 0 35 dB 10 nW Resolution 0 01 dB Linearity 5 Auto Power Off Yes Backlight Yes Refere...

Page 9: ...or dam aged contact Black Box Technical Support at 724 746 5500 Power meter Carrying case AC adapter Standard FC PC connector SC PC ST PC interchangeable connectors optional Printed Quick Start Guide...

Page 10: ...ter 2 Overview 2 3 Features Small compact unit is lightweight and is easy to carry Shifts units automatically also has auto off power capacity display and recharging display on the LCD Includes linear...

Page 11: ...Status Icon Description Full Battery at 100 capacity 2 Bars Battery at 50 75 capacity 1 Bar Battery at 25 50 capacity Empty Battery at 0 25 capacity The battery icon flashes when the power is almost d...

Page 12: ...t instead of batteries Plug the AC adapter s output cable into the DC input jack on the bottom of the power meter When the AC adapter is plugged in the AC indicator on the LCD will be displayed See Fi...

Page 13: ...d hold for more than two seconds while turning on to disable the auto off feature 2 Press to set the wavelength Select from six possible wavelengths 850 1300 1310 1490 1550 and 1625 nm 3 Press to sele...

Page 14: ...nectors DC input jack FC PC FC ST FC SC interchangeable connector optional Battery plate includes rechargeable lithium ion battery Figure 4 2 Optical Power Meter Basic connectors 4 1 3 LCD Reference W...

Page 15: ...wer meter 2 Press the ON OFF key briefly again The instrument powers off and back lighting switches off and the buzzer sounds briefly When the battery capacity indicator flashes on the LCD recharge th...

Page 16: ...ult wavelength is 1550 nm Figure 4 7 Setting the wavelength 4 4 Setting and Checking the Reference Level 1 Setting the reference level Press and hold the REF key for more than two seconds to store the...

Page 17: ...the LCD to indicate that it is a reference value The reference value will only be displayed for about one second The instrument then switches to the dB measurement mode Figure 4 9 Checking reference l...

Page 18: ...of the measuring range the LCD screen displays HI Figure 4 12 Power value high If the measured power value is lower than the lowest value of the measuring range the LCD screen displays LO Figure 4 13...

Page 19: ...ce When connected to the dual wavelength laser source FOLS SM 100 or FOLS MM 100 the FOPM 100 accurately measures the loss at distances up to than 250 kilometers at 1550 nm On the spot measurements wi...

Page 20: ...nd replace the protective dust cap once you finish using it Clean the connector and the instrument when they get dirty from use We recommend using optical cleaning pads and anhydrous alcohol Be carefu...

Page 21: ...te the problem or make it worse 6 2 Shipping and Packaging If you need to transport or ship your Optical Power Meter Basic Package it carefully We recommend that you use the original container If you...

Page 22: ...Page 22 724 746 5500 blackbox com NOTES...

Page 23: ...Page 23 724 746 5500 blackbox com NOTES...

Page 24: ...Black Box Network Services is your source for an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power and surge protection products to me...

Reviews: