background image

Page 19

SET UP & USE

WEAR AND TEAR

To minimize wear and tear on the air conditioner, always wait at least 3 minutes 

before changing modes. This will help prevent the compressor from overheating and 

the circuit breaker from tripping. 

CABINET CLEANING

To clean the air conditioner cabinet:

•  Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front 

panel of the air conditioner may be dusted with an oil free cloth or washed with a 

cloth dampened in a solution of warm water and mild liquid soap. Rinse thoroughly 

with a damp cloth and wipe dry.

• Never use harsh cleaners, wax or polish on the cabinet front.

•  Be sure to wring excess water from the cloth before wiping around the controls. 

Excess water in or around the controls may cause damage to the air conditioner.

Summary of Contents for BWAC05MWT

Page 1: ...estion or experience a problem with your BLACK DECKER purchase go to www blackanddecker com instantanswers If you can t find the answer or do not have access to the Internet call 844 299 0879 from 10...

Page 2: ...Page 2...

Page 3: ...will need it to obtain warranty service Model number Serial number Date of purchase PRODUCT REGISTRATION CONTENTS SAFETY INFORMATION Important Safety Instructions 4 8 Grounding Instructions 5 Safety...

Page 4: ...amination repairs or adjustments 4 DO NOT USE AN ADAPTER OR AN EXTENSION CORD 5 Do not block airflow around the air conditioner 6 Always unplug the air conditioner before servicing it or moving it 7 D...

Page 5: ...t The cord provided with this appliance is equipped with a grounding wire and a grounding plug The plug must be plugged into an outlet that is properly installed and grounded Avoid the use of three pr...

Page 6: ...grounding plug and a 3 slot receptacle that will accept the plug on the appliance b The marked electrical rating of the cord set or extension cord must equal to or greater than the electrical rating...

Page 7: ...n off the unit and unplug from the power supply immediately Do not operate your air conditioner in a wet room such as a bathroom or laundry room Do not touch the unit with wet or damp hands or when ba...

Page 8: ...the circuit should trip and cut all power to the air conditioner on some units a green light may turn off 4 Press the RESET button for use You will hear a click and the A C is not ready for use NOTES...

Page 9: ...IMAGE PART QUANTITY Window Air Conditioner 1 Top Mounting Rail 1 Sponge Window Sash Seal 1 Frame Lock 2 Filler Panels Marked Left Right 2 Sash Lock 1 Window Sash Seal 1 3 8 Screws 4 1 2 Screws 3 3 4...

Page 10: ...accordion panels to fit in a narrow window opening See the window dimensions 3 The lower sash the lower part of the window that moves up and down must allow for 14 5 of vertical clearance when open Se...

Page 11: ...face 2 Remove top rail from the bottom of the packaging material 3 Align the hole in the top rail with those in the top of the unit See Fig 2 4 Secure the top rail to the unit with the 3 8 screws See...

Page 12: ...e center to free the open end B Slide the free end of the panel into the cabinet Slide the panel down Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabine...

Page 13: ...tensions and the window sill Drive 3 4 locking screws through the frame lock and into the sill on both the left and right side See Fig 9 NOTE To prevent window sill from splitting drill 1 8 pilot hole...

Page 14: ...ifting unit from window Store parts WITH air conditioner WINTER STORAGE BEFORE REMOVING AIR CONDITIONER FROM WINDOW To store the air conditioner when it is not in use for an extended period of time re...

Page 15: ...ore turning it back on This prevents the air conditioner from blowing a fuse or tripping a circuit breaker Do not try to operate your air conditioner in the cooling mode when outside temperature is be...

Page 16: ...oose either or The air conditioner will not cool the room when in fan mode 4 THERMOSTAT Turn the TEMP dial to set the desired room temperature For maximum cooling turn the TEMP dial to 7 max cool 5 DI...

Page 17: ...idity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during rain or...

Page 18: ...low as well as cause the cooling coils to accumulate frost To clean the air filter 1 Remove the filter by sliding it out from the front right side of the air conditioner See Fig 14 2 Wash the filter u...

Page 19: ...the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm wate...

Page 20: ...in circuit breaker If these seem to be operating properly test the outlet with another appliance IF NONE OF THE ABOVE SOLVES THE PROBLEM CONTACT A QUALIFIED TECHNICIAN DO NOT TRY TO ADJUST OR REPAIR T...

Page 21: ...on The current interrupter device is tripped Press the RESET button located on the power cord plug If the RESET button will not stay engaged discontinue use of the air conditioner and contact a qualif...

Page 22: ...conditioner is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Mo...

Page 23: ...elay in service repair or replacement 14 Service calls to instruct you how to use your product 15 Service calls to repair or replace the house fuse reset the circuit breaker or correct the wiring in t...

Page 24: ...are trademarks of The Black Decker Corporation used under license All rights reserved Product in this box may differ slightly from that pictured Does not affect function Not all accessories shown in...