10.4  Problems Interfacing Serial Devices

Most problems experienced with connecting serial devices are caused by
incorrect cabling or incorrect handshake/protocol settings.  Do not assume
that, because a cable has the correct connectors and works between two other
devices, it will work when connected to the Modular Smart Switch.  Always use
the cabling specified in this manual (see 

Appendixes A 

and 

B

).  Incorrect

cabling may cause many different problems, such as:

• No data transmission

• Loss of data, corrupted prints and plots

• Unreliable file transfer

10.5  Serial Interfaces—No Data Transmitted through the Switch

Check that you can send data between your devices using a direct connection.
If you can’t, check your devices.  If you can, connect the Modular Smart
Switch and try sending a small amount of test data.

If the input channel indicator comes on, then no data is being sent into the

switch—check the cable between your PC and the Modular Smart Switch, and
check that you are sending the data from the correct port on your computer.  

If the channel indicator flickers or comes on, then data is being transferred

into the Modular Smart Switch.

If no data appears to be transmitted out from the Modular Smart Switch,

then check the cable between the switch and your output device.

If the channel indicators go out after the timeout period (usually 16

seconds), then all the data has been sent out of the switch.  If nothing appears
to have been received on your output device, then check the protocol (a
protocol problem often causes the data to be changed into a stream of null
characters).

10.6  Serial Interfaces—Corrupted Data

The most common cause of corrupted data when using serial interfaces is a
handshake problem.  If you experience corrupted data when using serial
ports, check that the protocols set on your equipment are the same as those
set on the Modular Smart Switch.  If you are using hardware handshake,
check that the hardware flow-control lines are connected on your cable.

50

MODULAR SMART SWITCH

10.  Troubleshooting

The Modular Smart Switch is designed to a high standard and all units are
fully tested before leaving the factory.  There are no user-serviceable parts.
If a fault persists, please contact technical support.

10.1  Self-Test at Power-On

The Modular Smart Switch automatically tests its basic operation when it
powers on.  The buffer indicators flash for a few seconds while the test is
being conducted and go out when the test has passed.  If the buffer indicators
do not flash or do not go out, then there may be a problem—consult
technical support.

10.2  Parallel Interfaces—No Data Transmitted through the Switch

If you have problems transmitting data through the switch using parallel
interfaces, make sure that the direction (input or output) has been set
correctly—see 

Section 4.2

.  If you have any problems in transmitting to

parallel ports, do not use the automatic in/out detection setting, because
this is not guaranteed to work with all printers.

The channel indicators show whether data is being routed correctly from

one port to another.

10.3  Parallel Interfaces—Corrupted, Extra, or Lost Data

Problems with corrupted data when using parallel communication are rare.
When problems do arise, they are mostly cabling problems.  Avoid using
ribbon cables.  Use shielded cables and keep the length to 22.9 ft. (7 m)
or less where possible.  Problem cables can cause occasional data corruption
and spurious page feeds on laser printers.

Summary of Contents for SW925A

Page 1: ...hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail info blackbox com APRIL 20...

Page 2: ...s operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever mea...

Page 3: ...ser le das antes de que el aparato el ctrico sea operado 2 Las instrucciones de seguridad y operaci n deber n ser guardadas para referencia futura 3 Todas las advertencias en el aparato el ctrico y e...

Page 4: ...22 5 7 Using the Modular Smart Switch 24 5 8 Port Indicators 1 to 12 24 5 9 Buffer Status Indicators 25 6 Using the Control Software 26 6 1 Installing the Resident Software 26 6 2 Running the Software...

Page 5: ...Transfer Software 42 8 3 Transferring Files Between PCs Not Compatible with IBM 42 8 4 General Hints and Tips 43 9 Software Commands 44 9 1 Introduction 44 9 2 Connect Command 45 9 2 1 Selecting a De...

Page 6: ...Meg Memory SW925A SW925AE includes Main chassis with 6 dual port module slots and 2 memory slots Software disk in 3 5 format Power lead with 115 VAC or 230 VAC plug 5 module blanking plates with fixi...

Page 7: ...ular Smart Switch contains two memory module slots A and B each of which can be fitted with a 1 MB or 2MB buffer memory module see Figure 3 1 The Modular Smart Switch is supplied as standard with a 1...

Page 8: ...ed on The buffer memory indicators will flash while the test is in progress and go off when the test is complete If all the channel and buffer indicators come on permanently then the buffer has been i...

Page 9: ...t Switch The ports on the Modular Smart Switch are configured using a number of option switches situated on the modules In addition to the port configuration the global timeout values can be set using...

Page 10: ...TPUT Automatic input output detection not guaranteed HIGH port switches LOW port switches 16 MODULAR SMART SWITCH Timeout Period When a user has sent no data for the timeout period the Modular Smart S...

Page 11: ...matic detection is not guaranteed to work with all equipment so if you experience any problems set the ports as dedicated inputs or outputs 4 3 Setting Serial Port Protocols and Options Protocols For...

Page 12: ...an existing cable is of the correct type because it has the correct connectors on each end or because it works between two other pieces of equipment Always use the cabling recommended in this manual C...

Page 13: ...57600 N 8 1 enter NOTE If you are sending plot print data from IBM compatibles using a serial port make sure that your AUTOEXEC BAT includes both the MODE with P option and ADMODE commands relevant to...

Page 14: ...eak in the transmission for more than the timeout period see Section 4 1 If two or more printers plotters are connected to the Modular Smart Switch you will need the software see Chapter 6 or software...

Page 15: ...be used can be specified once the software has been invoked using the PC PORT function and so these options are primarily for convenience only Hx H1 default 26 MODULAR SMART SWITCH 6 Using the Control...

Page 16: ...are as follows H1 selects CTRL ALT SHIFT H2 selects CTRL SHIFT H3 selects CTRL ALT H4 selects CTRL ALT H5 selects LEFT SHIFT RIGHT SHIFT SHIFT can be either the left or the right shift key The selecte...

Page 17: ...ected the PC port that you wish to use to print data With the dialog box displaying the correct PC port and DESTINATION highlighted press enter A new box will appear as shown below Enter the desired d...

Page 18: ...main menu NOTE Characters such as line feeds are displayed using an unusual set of non alphanumeric characters ADDER TECHNOLOGY ADMENU DIRECT OUTPUT DESTINATION FILE TRANSFER FUNCTIONS OPTIONS PORT 1...

Page 19: ...TIONS 34 MODULAR SMART SWITCH 6 9 Using the Functions Menu To enter the functions menu use the up and down cursor keys on the main menu to highlight FUNCTIONS and press enter The functions menu now al...

Page 20: ...tory on your PC At the DOS prompt type a command in the following format ADMODE COMn baud parity databits stopbits You only need to include a parameter after baud if it needs to be changed from the de...

Page 21: ...0 19200 4800 9600 19200 38400 57600 38400 57600 parity odd even none O E N N data bits 7 or 8 7 8 8 stop bits 1 or 2 1 2 1 Using the Control Software with Windows Version 3 1 Windows version 3 1 suppo...

Page 22: ...file transfer software A suitable batch file for Kermit would be as follows ADDER TECHNOLOGY ADMENU DESTINATION DIRECT OUTPUT FUNCTIONS OPTIONS PORT 1 COM1 ESC TO QUIT FILE TRANSFER ENTER TARGET PORT...

Page 23: ...th your Modular Smart Switch should be used together with file transfer software The control software allows you to increase the baud rate for all normal printing and plotting operations so you can us...

Page 24: ...and one copy on port 1 of every file sent from the computer issue the following command PM CONNECT 3 2 1 44 MODULAR SMART SWITCH 9 Software Commands 9 1 Introduction The Modular Smart Switch can be c...

Page 25: ...be switched off With the timeout off the output channel remains constantly dedicated to the input channel until an end of file command see Section 9 4 or a new connect command is sent The timeout rema...

Page 26: ...ine When the enter key is pressed the screen will display 1 File s copied This indicates that a file name TXT has been created that contains the software command text It is not normally possible to us...

Page 27: ...pted Data The most common cause of corrupted data when using serial interfaces is a handshake problem If you experience corrupted data when using serial ports check that the protocols set on your equi...

Page 28: ...TCH 10 7 Merged Printouts If the output from one computer has been printed in the middle of that from another you will probably need to increase the timeout period When no data has been sent from one...

Page 29: ...control in ve hardware HSIN Input handshake 25 Transmit data ve TXD Output A 2 Connecting to Computers RS 232 Connections RS 232 serial ports on computers tend to vary considerably The standard recom...

Page 30: ...Printers Most serial printers provide a standard DB25 connector for serial data The required cable wiring is shown in Figure A 3 This wiring configuration is suitable for many popular printers such as...

Page 31: ...TCH A 5 Connecting to Plotters A wide range of different pin configurations are used on plotter serial ports The following cable can be used for most plotters including those manufactured by Hewlett P...

Page 32: ...N HSIN TXD TXD HSOUT ve ve ve ve ve ve ve ve Flow control in Transmitted data out Flow control out Received data in 60 MODULAR SMART SWITCH A 7 Connecting to DEC LN03 Laser Printer The LN03 outputs it...

Page 33: ...16 INIT no connection OUTPUT high 17 SELECT IN no connection OUTPUT low 18 25 SIGNAL GROUND ground ground The cables need to have a DB25 connector for connecting to the Modular Smart Switch If possib...

Page 34: ...ect from IBM compatibles to the Modular Smart Switch require a 25 pin plug on both ends All lines should be connected straight through that is 1 to 1 2 to 2 etc B 3 Cable to 36 Pin Amphenol Connector...

Reviews: