3. Installation

For first-time users, we recommend that you carry out a test placement, confined to a single room, before commencing full instal-
lation. This will help you to identify and solve any cabling problems, and experiment with the KVM extender system more easily.

3.1 Interconnection Cable Requirements

To connect the local and remote ACS4001A-R2-SM units to the ServSwitch CWDM Mux box and to interconnect the ServSwitch 
CWDM Mux boxes, you’ll need:

•  Fiber cable: Two strands of fiber are required for connecting the local and remote ACS4001A-R2-SM units to the ServSwitch 

CWDM Mux box and to interconnect both Mux/Demux boxes.

• Recommended cables: Single-mode type 9/125 μ.

• Maximum cable length: Approximately 25 miles (40 km).

3.2 System Setup

To install your ServSwitch CWDM Mux system:

1. Switch off all devices.

2.  Install the ServSwitch CWDM Mux Transceivers in the local and remote CWDM Mux units. Each wavelength must not appear 

more than once in the system. Device pairs must carry transceivers with the same wavelength.

NOTES:  Each wavelength (1530, 1550, 1570, 1590 nm) must not be used more than once at each side! For four links, use four  

different wavelengths; for three links, use three different wavelengths; and for two links, use two different wavelengths.

           Each transceiver will work only at the appropriate port.

           The data will always flow between devices with the same wavelengths.

3.  Connect interconnection cables from the remote/local ACS4001A-R2-SM unit to ServSwitch CWDM Mux—make sure that you 

connect the transceivers to the matching port at the ServSwitch CWDM Mux.

4. Connect local and remote ServSwitch CWDM Mux units with matching interconnection cable (single-mode fiber).

5. Power on the system.

3.3 Diagnostics

There are no diagnostics on the ServSwitch CWDM Mux. Please use the capabilities of the attached units.

Summary of Contents for ServSwitch ACXCWDM4

Page 1: ...70 or 1590 nm ServSwitch CWDM Mux May 2010 ACXCWDM4 Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or...

Page 2: ...0 or go to blackbox com and click on Talk to Black Box You ll be live with one of our technical experts in less than 20 seconds Trademarks Used in this Manual Black Box and the Double Diamond logo are...

Page 3: ...n the equipment is operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to...

Page 4: ...idan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluy...

Page 5: ...feguard against personal injury and avoid possible damage to equipment or property Only use power supplies originally supplied with the product or manufacturer approved replacements Do not attempt to...

Page 6: ...ill Also Need 9 2 5 Accessories 9 2 6 Hardware Description 10 2 7 Example of a ServSwitch CWDM Mux System 10 2 8 Compatibility 11 3 Installation 12 3 1 Interconnection Cable Requirements 12 3 2 System...

Page 7: ...system Device pairs must carry transceivers with the same wavelength 2 Connect interconnection cables from remote local unit to the ServSwitch CWDM Mux make sure you connect the transceivers to the ma...

Page 8: ...m approx 25 miles Temperature Tolerance Operating 41 to 113 F 5 to 45 C Storage 13 to 140 F 25 to 60 C Relative Humidity Up to 80 noncondensing Power No power supply required Size ServSwitch CWDM Mux...

Page 9: ...e KVM extender unit 2 2 Features The ServSwitch CWDM Mux offers the following features Support for up to four data streams Support for 9 single mode fibers No power supply unit is required Small footp...

Page 10: ...able 2 1 Front panel components Number Component Description 1 Duplex LC connector 1530 port 2 Duplex LC connector 1550 port 3 Duplex LC connector 1570 port 4 Duplex LC connector 1590 port 5 Duplex LC...

Page 11: ...lackbox com Page 11 Chapter 2 Overview 2 8 Compatibility Interface compatibility Single mode fiber data Incoming optical light signals are multiplexed onto the single mode fiber and de multiplexed at...

Page 12: ...em 1 Switch off all devices 2 Install the ServSwitch CWDM Mux Transceivers in the local and remote CWDM Mux units Each wavelength must not appear more than once in the system Device pairs must carry t...

Page 13: ...tory of the problem We will be able to provide more efficient and accurate assistance if you have a complete description including The nature and duration of the problem When the problem occurs The co...

Page 14: ...ontact Black Box Technical Support at 724 746 5500 or info blackbox com 1 base plate 7 M2 5x2 spacers 3 blank plates 8 M2 5x5 Phillips countersunk screws You can mount up to two ServSwitch CWDM Muxes...

Page 15: ...nstalled by Digital Display Working Group www ddwg org R G B CLOCK in a data stream with up to 3x 1 6 Gbps signals are TMDS Level PSU The desktop power supply unit connected to the local remote unit H...

Page 16: ...g from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 20 seconds or less Copyright 2010...

Reviews: