POWER FALLBACK SWITCH - QUICK START GUIDE

 

5

Specifications

Physical/Environmental:

Width:

  17"  (48.3 cm) (Including Rack Brackets)

Depth:

  8.7"  (22.1 cm)

Height:

  1.75"  (4.5 cm) One Rack U

Operating Temperature:

  32˚F to 122˚F (0˚C to 50˚C)

Humidity:

  10 - 90% RH

Power Input Feeds:

PFBS120:

  Two (2) IEC-60320-C14 Inlets.

PFBS240:

  Two (2) IEC-60320-C20 Inlets.

Power Outlets:

PFBS120:

  Eight (8) each, NEMA 5-15R Outlets.

PFBS240:

  Eight (8) each, IEC-60320-C13 Outlets.

One (1) each, IEC-60320-C19 Outlets

Power Requirements and Maximum Load:

 

Model No.

Input 

Feeds (x2)

Input 

Voltage

Max. Load 

per Outlet

 

Outlets

Max. Load 

per Unit

PFBS120

15 Amps

100 to 120 VAC

12 Amps

8 ea. NEMA 5-15R

12 Amps*

PFBS240

20 Amps

200 to 240 VAC

10/16 Amps

8 ea. IEC-60320-C13 

1 ea. IEC-60320-C19

16 Amps*

*  In accordance with UL requirements for branch circuits, this value has been  

de-rated to 80%.

TRADEMARKS USED IN THIS MANUAL

BLACK BOX and the Double Diamond logo are registered trademarks of BB 

Technologies, Inc.

Any other trademarks mentioned in this manual are acknowledged to be the property 

of the trademark owners.

Summary of Contents for PFBS120

Page 1: ...call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www bl...

Page 2: ...likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly ap...

Page 3: ...el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo...

Page 4: ...quate clearance for venting Input Supply Check nameplate ratings to ensure that there is no overloading of supply circuits that could have an effect on overcurrent protection and supply wiring Groundi...

Page 5: ...One 1 each IEC 60320 C19 Outlets Power Requirements and Maximum Load Model No Input Feeds x2 Input Voltage Max Load per Outlet Outlets Max Load per Unit PFBS120 15 Amps 100 to 120 VAC 12 Amps 8 ea NE...

Page 6: ...r information concerning power requirements and maximum loads Notes After connecting your power cables to the Power Fallback Switch make certain to secure the cables in order to prevent accidental dis...

Page 7: ...POWER FALLBACK SWITCH QUICK START GUIDE 7...

Page 8: ...Copyright 2010 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746...

Reviews: