Black Box NET-ADVISOR User Manual Download Page 1

with the default Log time of 12 minutes (1 minute per division).
To begin the Log measurement, follow the procedure detailed
in the Traffic Mode section for attaching the instrument to the
cable, ensure that “LOCK" appears next to the elapsed time
display and press 

Enter

.  The Net-Advisor immediately begins

to build a histogram of the traffic levels.

The Log bar

graphs display the
average traffic
(“AV” bar graph in
the Traffic Mode)
and are scaled to

the currently selected maximum range with a default value of
10%.  The bar graphs are updated with every one second
measurement until time for the division is complete.  When a
division is complete, the bar graph for the current division is
frozen and the instrument begins displaying the bar graph for
the next division.  The Net-Advisor freezes the data by
automatically setting “HOLD” when all the divisions are complete.
Pressing Log will also create the “HOLD” condition.  Pressing
Log after “HOLD” appears will clear the display and reset the
Net-Advisor for another Log measurement.  All other buttons
(except “ON”) are active only when the Log Mode is in this reset
state.

The Net-Advisor can be left running even after the Log time

has been completed without affecting the recorded data.  For
Log durations of three hours or more, it is recommended that
the AC Adapter is used.

CONTROL SETTINGS

CONTROL SETTINGS

CONTROL SETTINGS

CONTROL SETTINGS

CONTROL SETTINGS

Audio/LED Contr

Audio/LED Contr

Audio/LED Contr

Audio/LED Contr

Audio/LED Control

ol

ol

ol

ol

From the Traffic screen

(in initial or reset state),
Audio or LED settings are
entered by pressing the
corresponding button.  Once
in Audio or LED the settings
change when the scroll
button is pressed.  Press
Enter to exit the screen.

I N T R O D U C T I O N

Theory of Operation

Computer networks communicate by transmitting

and receiving information in the form of digital
signals.  This information is electrically represented
by pulses of energy transmitted by a physical media
which is typically a metallic cable. Each pulse
travelling along a metallic cable creates an
electromagnetic field around the cable proportional
to the amplitude or strength of the pulse.  These
radiated or “leaked” signals are sometimes referred
to as Electromagnetic Interference or EMI.  Modern
cables use different techniques to reduce the amount
of leakage such as shielding or field cancellation by
tightly twisting the wires together. These techniques
dramatically reduce but can not eliminate the signal

leakage through the cable.

The Net-Advisor is an ultra-sensitive receiver tuned

to the different network frequencies that is able to
detect and measure the leaked signals from the
digital bits of data that are travelling through the
cable.  The Net-Advisor makes continuous
measurements of these network signals which are
displayed  and updated once per second.  The
measured data is displayed as a percentage of total
bandwidth.  For example, on an Ethernet system
(10baseT, 2 or 5) the maximum bandwidth is 10
million bits per second (Mbps).  If during a one
second measurement, the Net-Advisor detects one
million data bits the display will show a reading of
10% utilization.  The various features provided by
the Net-Advisor are based on this continuous
detection, measurement and display of the leaked
data bits.

The Net-Advisor reads all of the traffic on a

segment or dedicated port.  It does not filter for traffic
on a single node or address.  Traffic can be monitored
from any point on a network that is not isolated from
the rest of the network.

OPERA

OPERA

OPERA

OPERA

OPERATING MODES

TING MODES

TING MODES

TING MODES

TING MODES

Press 

ON

 to activate the Net-Advisor.  When the unit is turned

on it presents a Net-Advisor start up screen for 2.5 seconds and
automatically transitions to the Traffic screen which is the master
screen that is returned to from all other functions.

TRAFFIC

TRAFFIC

TRAFFIC

TRAFFIC

TRAFFIC

The Traffic Mode

starts with the
default conditions of
10 Mbps Ethernet
running on UTP

cable (10baseT).  If

the network to be tested is another configuration, go to the Setup
screen to select the appropriate parameters (see Control
Settings).  To begin taking measurements push forward the 

Slide

Button

 on the right hand side of the instrument to open the

cableport, place the selected cable in the port and release the
slide button to close.

The Net-Advisor

immediately begins
to sense for signals
and if any are
present it will display
the word “LOCK”

next to the elapsed time field.  This shows that there is adequate
leaked signal to make the measurement.  Note: The strength of
the leaked signals varies along the length of the cable.  It is
possible to find very small sections of a cable, typically 1 to 2
inches, where leakage is very low and “LOCK” appears
intermittently or not at all.  With the cable in the port, slide the
cable a few inches in either direction until “LOCK” appears
consistently or you have confirmed that no signals are present.

Once “LOCK”

appears, press

Enter

 to start the

measurement and
display process.
Pressing 

Traffic

  a

second time stops the process, freezes the recorded data and
presents the word “HOLD” in the display.  Pressing 

Traffic

 again

resets the Net-Advisor to make another traffic reading.  All other
buttons (except "ON") are active only when the Traffic Mode is
in this reset state.

Collision Index (CI ) - Is based on the calculated probability

of collisions occurring on the segment being tested.  This
probability applies to  Ethernet shared segments with "1"
indicating a very low probability and "5" indicating  a very high
probability of collisions occurring. CI is calculated from Average
Traffic and continuous readings of "4" or "5" indicate  system
upgrade should be considered. An arrowhead displayed in this
field means that a higher Max Range should be used.

T

T

T

T

Trrrrraf

af

af

af

affffffic bar g

ic bar g

ic bar g

ic bar g

ic bar grrrrra

aa

a

aphs:

phs:

phs:

phs:

phs:

IN - Instantaneous display of the network traffic

for the previous one second.

AV - The average of all the one second traffic

measurements since Enter was pressed.

PK - The peak traffic level recorded in any one

second measurement period.

Note:  When the Net-Advisor is first powered on, the full scale
default setting is 10%. The 10% setting gives a full scale dis-
play of 1 Mbps for Ethernet. The Net-Advisor is configured in
this manner because Ethernet network traffic levels are typi-
cally below  50% and this setting improves display resolution of
the bar graphs in the Traffic Screen.  To set full scale to any
other value go to the Setup Screen and make the selection -
see Setup below.

A Digital display for-
mat for Traffic is se-
lected in Setup
through the Max
Range field by
choosing "DD%".

L

LL

L

LOG

OG

OG

OG

OG

The Log Mode records network activity or bandwidth

utilization over time.
Log has seven
settings from 12
minutes to 24 hours
(see Setup below)

LED

LED

LED

LED

LED

LEDs are used

when viewing the
instrument at a
distance.  The
Net-Advisor is
designed so that

the LEDs can be viewed even when it is laid flat.  LEDs display
the Instantaneous traffic (“IN” bar graph in the Traffic Mode)
with each LED representing 10% of the full scale bandwidth.

A

A

A

A

AUDIO

UDIO

UDIO

UDIO

UDIO

Audio is used

to alert the user
when network
utilization has
exceeded the
selected level.

The Audio tone is tied to the Instantaneous traffic (“IN” bar graph
in the Traffic Mode) and is generated once during each one
second measurement if the threshold level has been exceeded.
Audio has 11 threshold settings beginning with “On” and
increasing in 10% increments to 100%.  The default setting is
“On” which will cause the tone to be generated when traffic is
detected during the measurement period.

SETUP

SETUP

SETUP

SETUP

SETUP

Setup has six

selectable fields
with the active
field being
indicated by the
arrowhead in

the center column of the screen.

Network Type.  When entering the Setup screen, the first field

shows that the Net-Advisor is for use with Ethernet (10BaseT)  .

Cable Type.  The default setting for Cable Type is Unshielded

Twisted Pair (Category 3, 4 or 5) and is indicated by the reversed
out “UTP”.  Press 

Scroll

 to advance to “STP” (Shielded Twisted

Pair) and then “COAX” for coaxial/thinnet/10base2 cables.

B

B

B

B

BA

A

A

A

ATTER

TTER

TTER

TTER

TTERY

Y

Y

Y

Y

The Net-Advisor operates on two AA size batteries.  To remove

the battery cover located at the bottom of the unit,  press down
on the battery cover end with dimples with the right thumb.  This
relieves the pressure on the battery cover latches. While pressing

down with the right thumb, slide
the cover horizontally (away
from your body). The cover will
move approximately one
quarter of an inch and separate
from the unit.

Add or replace batteries as

shown.  Check that the cover
orientation is correct by
ensuring that the AC adapter
hole in the cover is aligned with
the adapter jack pin inside the
Net-Advisor.

BO

BO

BO

BO

BOX CONTENTS

X CONTENTS

X CONTENTS

X CONTENTS

X CONTENTS

Net-Advisor

      Basic       RS

Data Clamp

          1         1

AC Adaptor

          1         1

Carrying Case

          1         1

User's Guide

          1         1

RS-232 Cable

        1

Sotware Diskettes

        2

AA Alkaline Batteries         2         2