80
2.048Mbps Wireless Modem
SALES: 0118 965 5100
Message:
WARNING:
Delay
setting
may
be
too
short
to
correct
all errors
Description:
The selected delay setting might be too short to allow the ARQ to correct the
bursts of radio errors present. Correction: Increase the delay setting or identify
and eliminate the cause of the bursts by using the tracers.
General Alarms
Message:
WARNING: LIU Clock drift, Check clock configuration
Description:
In E1/T1 configuration, failure to set the clock source of the end equipment
connected to the slave unit to loop-back mode.
Correction:
Check the clock configuration.
Message:
WARNING: LIU Clock frequency differs from set value
Description:
Indicates a clock rate different from the one specified in a V.35/RS-530/X.21
unit configured as DCE EXTERNAL CLOCK or as DTE.
Correction:
Correct clock frequency to set value.
Message:
WARNING: DPLL is noisy due to bad link conditions or
noisy input clock
Description:
Indicates that bad link conditions prevent the slave unit from synthesizing a
stable LIU clock.
Correction:
Check the link and the clock.
Message:
WARNING:
Too
many
links
to
synchronize,
Reduce
requested number
Description:
The specified number of links to synchronize is too high for the selected
hopping standard.
Correction:
Reduce the number of links to synchronize.