background image

APRIL 1994

ME770A

Mini Driver-15

CUSTOMER SUPPORT INFORMATION

Order 

toll-free

in the U.S.: Call 

877-877-BBOX

(outside U.S. call 

724-746-5500

)

FREE technical support 24 hours a day, 7 days a week: Call 

724-746-5500

or fax 

724-746-0746

Mailing address: 

Black Box Corporation

, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: 

www.blackbox.com

•   E-mail: 

[email protected]

Mini Driver-15

S/N

Summary of Contents for Mini Driver-15

Page 1: ...S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawren...

Page 2: ...operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measu...

Page 3: ...vabo s tano mojado o cerca de una alberca etc 6 El aparato el ctrico debe ser usado nicamente con carritos o pedestales que sean recomendados por el fabricante 7 El aparato el ctrico debe ser montado...

Page 4: ...contactos y recept culos donde salen del aparato 14 El equipo el ctrico debe ser limpiado nicamente de acuerdo a las recomendaciones del fabricante 15 En caso de existir una antena externa deber ser l...

Page 5: ...in Relief Assembly 13 Appendix 17 TRADEMARKS USED IN THIS MANUAL AT T is a registered trademark of American Telephone and Telegraph Company NCR is a registered trademark of NCR Corporation Unisys is a...

Page 6: ...tion 600W power dissipation at 1 ms and response time less than 1 0 picoseconds Control Signals DSR and DCD follow DTR from the terminal DTE CTS follows RTS from the terminal DTE Operation 4 wire unco...

Page 7: ...Range can be extended up to nine miles 14 5 km at 1200 bps An external DCE DTE switch lets you connect any device without opening the Driver Three enclosure options allow terminations via RJ 11 RJ 45...

Page 8: ...n power systems Features DC isolation between connected devices Includes an external DCE DTE switch Housed in a small size case 3 4 inch or 1 9 cm for closely spaced computer ports Uses modular plugs...

Page 9: ...lephone cable to XMT Transmit on the terminal block Be careful to observe polarity The wire connected to XMT must be connected to RCV in the other unit The wire connected to XMT must be connected to R...

Page 10: ...3 2 7 Plug the Driver directly into a mating RS 232C connector on your terminal or computer Tighten the two captive connector screws 1 Blue 2 Orange 3 Black 4 Red 5 Green 6 Yellow 7 Brown 8 Slate 1 B...

Page 11: ...J 11 jacks on the Driver are prewired for a standard AT T wiring environment To be sure you have the right wiring use these tables as guides RJ 11 Signal RJ 45 Signal 1 GND 1 N C 2 RCV 2 GND 3 XMT 3 R...

Page 12: ...D 6 White Blue 1 GND Connection to ground is optional These are standard AT T color codes Your colors may be different If your RS 232 application requires you to connect two pairs of bar wires to the...

Page 13: ...r between the DB25 connector and the lip of the plastic case You don t have to worry about breaking the plastic but be careful not to bend the D sub connector When the unit is open you ll be able to s...

Page 14: ...n 3 2 Installing the Strain Relief Assembly 1 Strip the outer insulation from the twisted pair wires about one inch 2 5 cm from the end 2 Strip back the insulation on each of the four twisted pair wir...

Page 15: ...d the other pair for receive signals RCV and RCV Note Terminal post locations may vary on different versions 4 Place the two halves of the strain relief assembly on either side of the telephone wire a...

Page 16: ...se Seat it into the recess in the case If a telephone wire is too thin to be held by the strain relief assembly use tape to increase its diameter If the wire is too large it may be necessary to drill...

Page 17: ...5 7 Insert one captive screw through a saddle washer Insert the captive screw with the washer on it through the hole in the DB25 end of the case Snap that side of the case closed Repeat the process fo...

Page 18: ...N TRANSFORMER ISOLATION 1 9 3 2 10 12 4 DATA V V INVERTING AMPLIFIER SCHMITT TRIGER ACTIVE FILTERS 2 STAGES TRANSIENT SUPPRESSION DATA TRANSIENT SUPPRESSION AMPLIFIER A 1 5 o SIGNAL CLAMPED TO 1 VOLT...

Page 19: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1994 Black Box Corporation All rights reserved...

Reviews: