ME801A-E

J1

RS-232

CONNECTOR

SPECIFICATIONS:

Interface:  RS-232-C (DCE) to attached local device;

Proprietary balanced 4-wire to line.

Protocol:  Synchronous

Clock Source:  Local internal (each SHM-B Sync unit

independently generates it's own clock.

Operation:  4-wire, Full Duplex, point-to-point.

Flow Control:  Hardware (RTS and/or DTR), local only (control

signals are not passed across the 4-wire line;
transparent to software (X-ON/X-OFF).

Data Rate:  19,200, 9600, 4800, 2400, 1200, or 600 bps.

Loopback:  Simultaneous local loopback to attached RS-232

device and remote loopback to remote SHM-B Sync
(user-controllable)

User Controls:  (1) Front-mounted push-button to turn loopback

ON and OFF.  (6) Internal pairs of jumper posts for
setting the data rate.  (3) Internal pairs of jumper posts
for setting CTS delay.

Connectors:  (1) DB25 Female connector;  (1) 4-screw

terminal block.

Indicators:  (2);  (1) TD and (1) RD.

Leads/Signals Supported:  RS-232:  TD, RD, RTS, CTS, DSR,

SGND, DCD, TC, RC, DTR.  Pins 1 thru 8, 15, 17,
and 20.

Surge Protection:  Internal opto-isolators (effective up to

20 VDC) on transmit and receive lines.

Power:  Power is supplied by a wall-mounted power transformer.

Primary /- 10%, 50 Hz, 5 watts.
Secondary:  17 VAC, 700 ma
External Power Supply Part # = PS008E

S2

Loopback

TD

RD

TERMINAL

BLOCK

GND

LONG

SHORT

NONE

CTS-DELAY

SELECTION

600

1200

2400

4800

9600

19200

DATA RATE

SELECTION

Data Rate

in bps

Distance

in miles

Distance

in km

19,200

9,600
4,800
2,400
1,200

600

.75

.9

1
2

3.5

5

1.2
1.4

8

5.6

1.6
3.2

INTRODUCTION:

     The Short-Haul Modem-B Sync (SHM-B Sync for short) is a synchronous full-duplex 4-wire line
driver and receiver that makes it possible for two RS-232-C devices to communicate across
distances up to 5 miles (8 km), at data rates up to 19,200 bps.  In addition to its transmitter and
receiver circuits, the SHM-B Sync also features status LED's a loopback switch, and support for
RS-232 clock and control signals.
     The SHM-B Sync is designed to operate with 4-wire cable.  It is also designed for maximum
operator safety.  There are no voltages greater than 12 VDC or 17 VAC present on the unit's circuit
board.  Opto-isolation circuits protect both the transmit and receive lines against voltage surges (up
to 20 VDC) such as those caused by lightning.
     The SHM-B Sync is available in either a 120-VAC (ME801A) or 220-VAC (ME801A-E)
standalone version or a card version (ME801-C) that will fit in our ME810 or RM007 card chassis.

CONFIGURATION:

     Before you install a pair a SHM-B Sync units, you should set their configuration jumpers as
necessary.

Caution!

If you have the card version, make very sure that the SHM-B
Sync card is not installed in a powered chassis when you
configure it.  If you have the standalone version, make sure
that it is unplugged and is disconnected from any other devices.
No voltages greater than 17 VAC are ever present on the board
even when it is powered, but the possibility of electric shock
should always be avoided.
     When you handle the SHM-B Sync's circuit board, take every
reasonable precaution against damaging the board with static
electricity.  At the very least, discharge yourself by touching a
fixed metal surface before handling the board; if possible, stand
on an anti-static mat and wear a grounding strap or anti-static
gloves.

There are two sets of jumper posts mounted on the SHM-B Sync's circuit board.

1.  Six pairs of posts are used to set the SHM-B Sync's data rate.  They're at the front of
     the left-hand side of the board.  The six possible data-rate settings are 600, 1200,
     2400, 4800, 9600, and 19200 bps. The factory-default value is 9600 bps; if your
      RS-232 equipment is using one of the other data rates, set the jumpers in both units
     accordingly by moving the jumper to the appropriate pair of posts.  (The SHM-B Sync
     units must both be set to the same data rate, which they will generate internally; the
     attached devices must be set to accept clock from them).
2.  Three pairs of posts are used to set the SHM-B Sync's CTS delay.  They are at the
     rear of the right-hand side of the board.  The CTS delay is the amount of time that the
     SHM-B Sync waits after detecting that the attached device has raised RTS before it
     responds by raising CTS.  The possible settings are LONG (53 ms), SHORT (7 ms)
     or NONE.  Factory default is NONE, but if your RS-232 device needs to see a CTS
     delay in order to function properly, move the jumper to the appropriate post in that
     SHM-B Sync only.

INSTALLATION:

1.  Open the case of one of the SHM-B Sync units.
2.  Thread the bare ends of the four wires into the four screw terminals on the SHM-B
     Sync's board marked RX+, RX-, TX+, and TX-.  Refer to drawing on the next page for
     proper wiring of the terminal blocks.
3.  Plug one end of an RS-232 cable into the DB25 female connector on the rear of the
     unit.  Avoid running this cable farther than 50 ft.
4.  Plug the other end of the RS-232 cable into a powered-down device whose serial
     communication you want to extend.
5.  Repeat steps 1 thru 4 with the remote site's SHM-B Sync unit.

   