background image

1

Connect up to four
workstations to one
Token Ring lobe.

Reduces cabling and
installation costs.

Models available for
UTP or STP cable.

Autosenses data rates
of 4 or 16Mbps.

Wire-fault detection
disconnects from the
ring automatically in
case of shorts, open
circuits, or incorrect
speeds.

C

onnect two or four token-ring
workstations to a single lobe

with the Smart Lobe Access Unit.
You save on cabling and
installation costs by adding
workstations to the ring without
adding extra lobe cables to the
central hub.

Three Smart Lobe Access Unit

models are available: 4-port
versions for either ordinary
unshielded twisted-pair (UTP) or
shielded twisted-pair (STP) cable
and a 2-port version for UTP
cable.

The Smart Lobe Access Units

feature wire-fault detection,
which senses any short, open, or
illegal impedance in the main lobe
connection. If a fault is detected,
the Access Unit deinserts all
connected workstations.

Power the Smart Lobe Access

Unit from an external DC power
adapter via the MAIN connector
(requires 6-wire cabling) or via a
modular power jack.

Double or quadruple a

single lobe’s capacity!

Key Features

SMART LOBE ACCESS UNIT

Black Box Corporation

• 1000 Park Drive • Lawrence, PA 15055-1018 • Tech Support: 724-746-5500 • 

www.blackbox.com

• 

e-mail: [email protected]

© 2005. All rights reserved.

Black Box Corporation.

4/1/2005

#19194

Input Voltage: 

11 to 35 VDC 

(12 VDC typical)

Input Current: 

2-Port models:

100 mA @ 12 VDC; 4-Port models:
140 mA @ 12 VDC 

Operating Voltage: 

4.5±0.7 volts

Operating Current:

2-Port models:

140 mA @ 5 VDC; 4-Port models:
240 mA @ 5 VDC; Phantom
circuit: 1.0 mA @ 5 VDC

Resistance TX to RX:

4.8±0.2 k

Insertion Time:

5 milliseconds

(typical)

Removal Time:

5 milliseconds

(typical)

Jumper:

4- or 16-Mbps rate

selection (4M/16M)

Compliance:

FCC Part A; Complies

with EMC EN 55022 (1994), EN
50082-1 (1992), and EMC
Directive 89/336/EEC

Operating Temperature: 

32 to 122°F

(0 to 50°C)

Relative Humidity Tolerance:

10 to 90%, noncondensing

Speed:

4 or 16 Mbps, autosensing

Connectors:

LT0007A-2U: 

(3) unshielded RJ-45;

LT0007A-4U: (5) unshielded 

RJ-45; 

LT0007A-4SU: (5) shielded RJ-45

Indicators:

(3) or (5) Red LEDs,

depending on which model you
have

Power:

115- or 230-VAC external DC

power supply (can also be
powered remotely via Pins 7 and
8 of the main connector)

Size:

7.3"H x 4.5"W x 1.5"D 

(18.5 x 11.4 x 3.8 cm)

Weight: 

2 lb (0.9 kg)

Specifications