background image

Compact Media Converter TP/BNC (left) and TP/FO (right), Front View

Once installed, you can configure Compact Media Converter TP/FO for

the following:

•  Select a crossover or pass-through connection for the twisted 

pair port (default = OUT/crossover)

• Enable LinkLoss (default = DOWN/disabled)
• Enable FiberAlert (default = DOWN/disabled)

Compact Media Converter TP/BNC

can be configured for the

following features:

Select a crossover or pass-through connection for the twisted

pair port (default = OUT/crossover)
Disable BNC port termination (default = ON position/enabled)

Twisted Pair Crossover/Pass-Through Switch

The twisted pair port on Compact Media Converter has one RJ-45

connector for a single shielded or unshielded twisted pair link segment,

and features a push-button switch, located next to the twisted pair

connector, for selecting a crossover workstation connection or pass-

through repeater/hub connection.  Select a pass-through connection by

pressing the push-button IN.  A crossover connection is selected when

the push-button is OUT.

If uncertain whether a crossover or pass-through connection is

needed, set the push-button to the position that makes the link LED

glow.

BNC Port Termination

Compact Media Converter TP/BNC

features a   

2-position switch next to the BNC connector that

allows a thin coaxial segment to be terminated at

the port without an additional ‘T’ connector and

terminator.

If Compact Media Converter TP/BNC is

attached to a mid-point of a thin Ethernet

segment, attach a ‘T’ connector to the BNC port.  Termination must be

OFF (disabled).  Termination is disabled when the switch is in the left

position.

TERM

OFF/ON

10 Mbps

X II

TP RCV

BNC RCV

TP LNK
BNC COL

Crossover/

pass-through

switch

Twisted Pair

port

BNC

Termination

switch

Thin Coaxial

port

LEDs

724-746-5500

Compact

Media Converter

RCV

XMT

MM850

10 Mbps

X II

FO RCV

FO LNK

TP LNK
FA

724-746-5500

Compact

Media Converter

LL FA

Crossover/

pass-through

switch

Twisted Pair

port

FiberAlert and

LinkLoss

switches

Fiber Optic

port

LEDs

2

1

Compact Media Converter

Installation Guide

LMC001A-R2 - LMC002A-R2 - LMC003A-R2

LMC004A-R2 - LMC005A-R2 - LMC006A-R2 

LMC007A-R2 - LMC008A-R2 - LMC009A

Black Box’s Compact Media Converter is a low-cost, preconfigured,

IEEE 802.3 single-conversion media converter that converts between

10Base-T twisted pair and 10Base-FL (multi-mode or single-mode) fiber

or 10Base-2 thin coax.  It is available with one RJ-45 connector for the

twisted pair port and one pair ST or SC connectors for the fiber port or

one BNC connector for the coax port.

Compact Media Converter

is a 1U high, standalone unit that includes

diagnostic LEDs for each port and a universal (100-240 VAC) power

supply.  The following Compact Media Converter versions are available:

10BT (RJ-45) - 10BFL 

— 10Base-T twisted pair/10Base-FL 850 nm

multi-mode fiber; includes one RJ-45 connector and one pair ST

(LMC001A-R2) or SC (LMC002A-R2) connectors.
10BT (RJ-45) - 10BFL/1300 

— 10Base-T twisted pair/10Base-FL 1300

nm multi-mode fiber; includes one RJ-45 connector and one pair ST

(LMC003A-R2) or SC (LMC004A-R2) connectors.
10BT (RJ-45) - 10BFL SM 

— 10Base-T twisted pair/10Base-FL 1300

nm single-mode fiber; includes one RJ-45 connector and one pair ST

(LMC005A-R2) or SC (LMC006A-R2) connectors.
10BT (RJ-45) - 10BFL SM/PLUS

— same as above with higher power

budget; includes one RJ-45 connector and one pair ST 

(LMC007A-R2) or SC (LMC008A-R2) connectors.
10BT (RJ-45) - 10B2 (BNC)

— 10Base-T twisted pair/10Base-2 thin

coaxial; includes one RJ-45 connector and one BNC connector

(LMC009A)

Installing Compact Media Converter

Compact Media Converter 

comes ready to install.  The only

adjustments that may need to be made come after installation.

To install Compact Media Converter, first make sure that the unit is

placed on a suitable flat surface.  Attach the cables between the
Compact Media Converter

and each device that will be interconnected,

then plug the unit into a reliable, filtered power source.

Configuring Compact Media Converter

The diagram on the following page shows the switches and

connections on Compact Media Converter TP/BNC and TP/FO.

Reviews: