background image

24/7 TECHNICAL SUPPORT AT 1.877.877.2269 OR VISIT BLACKBOX.COM

INDUSTRIAL 

GB POE MEDIA 

CONVERTER

QUICK INSTALL GUIDE/USER MANUAL

LGC5500A

ON

1  2  

3

ON

1  2  

3

P1

P2

   1

ETH             10/100/1000M

DPX

LNK/ACT

   2

LFP

LFP

Fault

LNK/ACT

Speed

Fault Relay 

SW 2

PoE

100

100/1000X

P2 

P1 

LFP

SW 1

Fail Close

Fail  Open

Fault Relay 

Summary of Contents for LGC5500A

Page 1: ...ACKBOX COM INDUSTRIAL GB POE MEDIA CONVERTER QUICK INSTALL GUIDE USER MANUAL LGC5500A ON 1 2 3 ON 1 2 3 P1 P2 1 ETH 10 100 1000M DPX LNK ACT 2 LFP LFP Fault LNK ACT Speed Fault Relay SW 2 PoE 100 100 1000X P2 P1 LFP SW 1 Fail Close Fail Open Fault Relay ...

Page 2: ...2 4 Compatible SFPs 11 3 CONFIGURATION 12 DIP Switch Settings 12 4 INSTALLATION 13 4 1 Preparation 13 4 2 DIN Rail Installation 13 4 3 Wallmounting 14 4 4 Network Connection 14 4 5 Terminal Block Wiring 15 5 OPERATION 16 LEDs 16 APPENDIX A DIMENSIONAL DIAGRAM 17 APPENDIX B REGULATORY INFORMATION 18 B 1 FCC Class A Statement 18 B 2 CE and RoHS2 18 B 3 Additional Certifications 19 APPENDIX C DISCLAI...

Page 3: ...perature specified by the manufacturer Reduced Air Flow Installation of the equipment should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mount the equipment in the DIN rail so that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of th...

Page 4: ...osoft Internet Explorer 6 0 or later for using web based system management tools Package Contents 1 Industrial Gigabit PoE Media Converter unit 1 DIN Rail kit 1 Wallmount kit 1 4 pin terminal block STEP 2A DIN RAIL INSTALLATION 1 Slant the switch and screw the DIN rail kit onto the back of the switch right in the middle of the back panel FIGURE Q 1 2 Slide the switch onto a DIN rail from the DIN r...

Page 5: ... Q 2 2 Use the switch with wallmount plates attached as a guide to mark the correct locations of the four screws 3 Insert four screw heads through the large parts of the keyhole shaped apertures and then slide the switch downwards Tighten the four screws for added stability STEP 3 NETWORK CONNECTION The device has a standard Ethernet port According to the link type the device uses CAT3 4 5 5e UTP ...

Page 6: ...lure detection 3 LFP warning detection ON LFP signals detection enable relay output OFF Disable LFP signals detection TABLE Q 2 2 PIN DIP SWITCH 2 SETTINGS DIP SWITCH POSITION FUNCTION STATUS 1 100 1000BASE FX mode selection ON 100BASE FX mode OFF 1000BASE FX mode 2 LFP function ON Enable LFP function OFF Disable LFP function STEP 5 TERMINAL BLOCK WIRING The switch supports dual redundant power su...

Page 7: ...apacity of 1 A at 24 VDC at pin terminal block Power Input Power Dual 50 to 57 VDC voltage power inputs in 4 pin terminal block Power consumption Typ 4 Watts unit only does not include PoE Overload current protection Present Reverse polarity protection Present on terminal block Physical Enclosure IP 30 Dimensions 3 74 H x 1 61 W x 2 76 D 9 5 x 4 1 x 7 cm Weight 0 64 lb 291 g Environmental Storage ...

Page 8: ... to transmit packets and will wait for a response that never arrives from the disconnected side LFP can be easily enabled using the DIP switch Once enabled the link will shut down as soon as it is notified that the other link has failed giving the application software a chance to react to the situation The LGC5500A has a wide operating temperature range from 40 to 167 F 40 to 75 C and a wide volta...

Page 9: ...9 1 877 877 2269 BLACKBOX COM NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 CHAPTER 2 OVERVIEW 14 14 15 FIGURE 2 2 TOP PANEL 16 FIGURE 2 3 BACK PANEL ...

Page 10: ... 2 2 for compatible SFP modules 8 DIP switch 2 Sets 100 1000BASE FX mode selection and LFP function See Table 3 2 9 Gigabit port LNK ACT LED Lights green when port is linked 10 Gigabit port 10 100 1000 RJ 45 port links to Gigabit Ethernet 11 Gigabit port speed LED Lights green when port is running at 1000 Mbps Lights amber when port is running at 100 Mbps Off when port is running at 10 Mbps 12 DIP...

Page 11: ...LFP404 SFP 155 Mbps Extended Diagnostics 1310 nm Single Mode Fiber 60 km LC LFP411 SFP 1250 Mbps Extended Diagnostics 850 nm Multimode Fiber 550 m LC LFP412 SFP 1250 Mbps Extended Diagnostics 1310 nm Multimode Fiber 2 km LC LFP413 SFP 1250 Mbps Extended Diagnostics 1310 nm Single Mode Fiber 10 km LC LFP414 SFP 1250 Mbps Extended Diagnostics 1310 nm Single Mode Fiber 30 km LC LFP416 SFP 1250 Mbps E...

Page 12: ...DIP SWITCH FUNCTION STATUS 1 Power 1 failure detection ON When power1 fails enable relay output OFF Disable power 1 failure detection 2 Power 2 failure detection ON When power2 fails enable relay output OFF Disable power 2 failure detection 3 LFP warning detection ON LFP signals detection enable relay output OFF Disable LFP signals detection TABLE 3 2 2 PIN DIP SWITCH 2 SETTING DIP SWITCH FUNCTION...

Page 13: ...ternet Explorer 6 0 or later for using web based system management tools Package Contents 1 Industrial Gigabit PoE Media Converter unit 1 DIN Rail kit 1 Wallmount kit 1 4 pin terminal block 4 2 DIN RAIL INSTALLATION 1 Slant the switch and screw the DIN rail kit onto the back of the switch right in the middle of the back panel FIGURE 4 1 2 Slide the switch onto a DIN rail from the DIN rail kit and ...

Page 14: ...four screws 3 Insert four screw heads through the large parts of the keyhole shaped apertures and then slide the switch downwards Tighten the four screws for added stability 4 4 NETWORK CONNECTION The device has a standard Ethernet port According to the link type the device uses CAT3 4 5 5e UTP cables to connect to any other network devices PCs servers switches routers or hubs TABLE 4 1 CABLE TYPE...

Page 15: ...r input 7 Not used 8 Not used TABLE 4 3 1000BASE T P S E RJ 45 PIN DEFINITION PIN NUMBER DESCRIPTION 1 BI_DA with PoE Power input 2 BI_DA with PoE Power input 3 BI_DB with PoE Power input 4 BI_DC 5 BI_DC 6 BI_DB with PoE Power input 7 BI_DD 8 BI_DD 4 5 TERMINAL BLOCK WIRING The switch supports dual redundant power supplies which are located on the 4 pin terminal block 1 Insert the negative positiv...

Page 16: ...een ON DC power module2 activated PoE Green ON Power is supplied over Ethernet cable Fault Amber ON An unexpected event occurred TABLE 5 2 10 100 1000 BASE T X RJ 45 PORT LEDS LED COLOR STATUS DESCRIPTION LNK ACT Green ON Port is linked Green Blinking Acting None OFF Port is disconnected Speed Green ON Port is running at 1000 Mbps Amber ON Port is running at 100 Mbps None OFF Port is running at 10...

Page 17: ...ECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 APPENDIX A DIMENSIONAL DIAGRAM 22 0 20 0 28 0 24 7 13 1 70 0 29 0 41 0 3 0 5 9 24 7 33 6 8 0 43 5 25 3 50 0 95 0 41 0 14 0 13 5 40 0 FIGURE A 1 DIMENSIONAL DIAGRAM NOTE Dimensions are in millimeters mm ...

Page 18: ...n a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital app...

Page 19: ...7 TECHNICAL SUPPORT 1 877 877 2269 APPENDIX B REGULATORY INFORMATION B 3 ADDITIONAL CERTIFICATIONS EMS EN61000 4 2 EN61000 4 3 EN61000 4 4 EN61000 4 5 EN61000 4 6 EN61000 4 8 EN61000 4 11 Shock IEC60068 2 27 Free Fall IEC60068 2 32 Vibration IEC60068 2 6 Safety EN60950 1 ...

Page 20: ...ve consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any time without notice C 2 TRADEMARKS USED IN THIS MANUAL Black Box and the Black Box logo type and mark are registered trademarks of Black Box Corporation Any other trademarks mentioned in this manual are...

Page 21: ...____________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________...

Page 22: ...__________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ ____________________________________________...

Page 23: ...____ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________...

Page 24: ...NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 COPYRIGHT 2019 BLACK BOX CORPORATION ALL RIGHTS RESERVED LGC5500A_QIG USER_REV1 PDF ...

Reviews: