INSTALLATION
21
To start, identify the following prior to installation:
1.
Which ServSwitch Console Plus will be #1, #2, and so on.
2.
Which computer will be #1, #2, and so on.
3.
Which computers do not use a PC2 keyboard or a PS/2 mouse.
4.
Which Unit and CPU port each computer will be connected to.
5.
The “Starting computer” number for each Unit.
6.
The number of computers, or “Maximum computers”, that the ServSwitch
Console Plus will be managing.
The “Starting computer” and “Maximum computers” values are determined as
follows:
Starting computer
The “Starting computer” number will depend on which Unit is being
configured. The “Starting computer” number for the first Unit is always one
(default). Using Units that have 16 CPU ports, the “Starting computer”
number for the second Unit is the total number of CPU ports on the first Unit
+ one or 17, the third Unit would have a “Starting computer” number of 33
(Total CPU ports on unit #1 and unit #2 + 1, and so on.
Maximum computers
The “Maximum computers” value is calculated by counting the total number of
CPU ports on all units. If your system consists of 10 ServSwitch Console Plus
Units, each with 16 CPU ports, the “Maximum computers” number would be
160. The “Maximum computers” value must be entered from a KVM station
and when saved, this value is propagated to all connected Units.
Connecting the expansion units
The installation steps below are for all ServSwitch Console Plus models.
(NOTE: Expansion cables should not be connected at this point)
Steps:
1.
Verify that power is “OFF” on all ServSwitch Console Plus switches
.
2.
Configure the “Starting computer” number for all the ServSwitch Console
Plus switches, starting with Unit #2 by: (Unit #1 default = 1)
a.
Connect a KVM station to Unit #2’s KVM connector using the
appropriate KVM adapter cable.
b.
Apply power to the KVM monitor and to ServSwitch Console Plus #2.
c.
When the internal diagnostic completes, press and release the left
control [Ctrl] key, then the F12 key to display the “Main menu”.
d.
Select “System” and press [Enter].
e.
Next, select “Starting computer number” and press [Enter]. An input
box will display for a new starting computer number. Enter the
correct “Starting computer” number for this Unit (See page 15) and
press [Enter].
Press the “Esc” key to return to the “Main menu”.