Page 33
877-877-2269 | blackbox.com
Chapter 5: Connecting
IR Output
This mode of versatile port provides output for infra-red emitters (IR Adapters). Parameters of IR output are as follows:
• The maximum IR carrier frequency is 500 kHz.
• Up to three original infra-red emitters (IR Adapters) can be connected to each output in parallel. All emitters send the same
IR codes. This configuration can be used for different types of devices.
WARNING: We do not recommend connecting more infra-red emitters from various manufacturers in parallel
because the output can be either overloaded or damaged.
Connecting
S G
Controlled Device 1
Controlled Device 2
Controlled Device 3
IR Adapter
IR Adapter
IR Adapter
FIgure 5-10. IR output.
Serial Output
This mode provides one-way RS-232 output channel.
Serial output parameters are as follows:
• RS-232 mode only
• Serial data baud rate 300 bps to 115,200 bps
WARNING: If there are more ports in the unit, all pins labelled G are connected together.
Connecting
S G
Controlled
Device
RxD
G
Figure 5-11. Serial output.