Chapter 5: Connecting

Bi-directional Serial RS-232/422/485

These bi-directional serial channels are used for RS-232, RS-422, and RS-485 communication. The maximum speed is 115,200 

bps. The default mode for all channels is RS-232; you must set other modes in the programming application. For more details, 

see the programming manuals.

RS-232 Mode

Output signal levels for RS-232 are in the -10 V to +10 V range. This is the default mode for all channels.

Table 5-7. RS-232 pinout.

SERIAL RS-232 

5-pin 3.5 mm

Pin

Signal

Description

Direction

1 2 3 4 5

1

TxD

RS-232 Transmitted Data

From controller

2

RTS

RS-232 Request to Send

From controller

3

GND

Ground

4

RxD

RS-232 Received Data

To controller

5

CTS

RS-232 Clear to Send

To controller

RS-422 Mode

You must set this mode in the programming application.

Table 5-8. RS-422 pinout.

SERIAL RS-422

5-pin 3.5 mm

Pin

Signal

Description

Direction

1 2 3 4 5

1

Tx A+

RS-422 Transmit Data (Idles High)

From controller

2

Tx B-

RS-422 Transmit Data (Idles Low)

From controller

3

GND

Ground

4

Rx A+

RS-422 Receive Data (Idles High)

To controller

5

Rx B-

RS-422 Receive Data (Idles Low)

To controller

RS-485 Mode

You must set this mode in the programming application.

Table 5-9. RS-485 pinout.

SERIAL RS-485 

5-pin 3.5 mm

Pin

Signal

Description

1 2 3 4 5

1

A+

RS-485 Data +

2

B-

RS-485 Data -

3

GND

Ground

4

N.C.

Not Connected

5

N.C.

Not Connected

Summary of Contents for ControlBridge CB-ACC-232DCE-30

Page 1: ...trolBridge Processor CB CP100 CB ACC 232DTE 30 CB PS 12V CB CP200 CB ACC 232DCE 30 CB PS 24V CB ACC IR UNI CB APP LIC CB CP RMK Order toll free in the U S or for FREE technical support Call 877 877 BBOX outside U S call 724 746 5500 www blackbox com info blackbox com Contact Information ...

Page 2: ...Support at 877 877 2269 or go to blackbox com and click on Talk to Black Box You ll be live with one of our technical experts in less than 60 seconds Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners ...

Page 3: ...wn expense will be required to take whatever measures may be necessary to correct the interference Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emis sion from digital apparatus set out in the Radio Interference Regulation of I...

Page 4: ...an el flujo de aire por los orificios de ventilación 10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos incluyendo amplificadores que producen calor 11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación o como se indique en el aparato 12 Precau...

Page 5: ...2 Indicators 16 4 3 IR Sensor 17 4 3 1 Capturing IR Codes 18 4 3 2 IR Control Panels Receiver 19 5 Connecting 20 5 1 Power In 20 5 2 Power over Ethernet 21 5 3 ControlBridge Network 21 5 4 Serial 25 5 5 Versatile I O Ports 27 5 6 General I O 35 5 7 Relay 36 5 8 Audio Line 36 6 Upload User Application 38 6 1 Using ControlBridge Builder 38 6 2 Using Admin Control Panel 39 7 Admin Control Panel 40 7 ...

Page 6: ...Analog In Digital Out 4 IR Receivers For capture 1 For capture 1 For wireless control panels 1 IR Serial Output 4 Low Voltage Relay 24 V 0 5 A 2 RAM Non volatile flash 64 MB 256 MB 512 MB 4 GB minimum Versatile I O Ports 8 Wired 10 100BASE T Ethernet 1 1 Power 24 VDC power supply maximum 4 W PoE IEEE 802 3af Class 0 24 VDC power supply maximum 4 W PoE IEEE 802 3af Class 0 Dimensions 1 7 H x 4 1 W ...

Page 7: ...ble Ethernet connection provides easy network integration The controllers are equipped with Power over Ethernet PoE technology enabling an Ethernet network cable to deliver both data and power This controller comes complete with a web server and allows setup through a standard web browser Unit programming is based on the Black Box standard programming tool ControlBridge Builder Both models include...

Page 8: ...g is missing or damaged contact Black Box Technical Support at 877 877 BBOX 2267 or info blackbox com CB CP100 1 ControlBridge 100 1 24 VDC power supply 1 straight through Ethernet cable 2 IR adapters 1 connector set CB CP200 1 ControlBridge 200 1 24 VDC power supply 1 straight through Ethernet cable 4 IR adapters 1 connector set ...

Page 9: ...ows the ControlBridge Processor 100 CB CP100 Table 2 1 describes its components 43 5 mm 105 mm Versatile ports Bi directional serial ports 24 VDC power supply System Default button Ethernet with PoE Versatile port indicators IR capture sensor Serial port indicators Power link and CPU indicators Figure 2 1 ControlBridge Processor 100 ...

Page 10: ...485 Bi directional serial port 1 RS 232 422 485withpower24VDC IR Serial output 1 4 Ethernet activity indicator yellow Ethernet link indicator green Unbalanced audio line output Unbalanced audio line input Ethernet Button Factory Default General I O 1 4 indicators green IR Serial 1 4 indicators yellow Relay 1 2 indicators red Serial 1 2 indicators green red Power indicator blue Ethernet indicator g...

Page 11: ...The adapter mounts on the receiver window using double sided adhesive tape 2 pin 3 5 mm connector IR emitter Figure 2 3 IR adapter Serial IO Cable DTE The Serial IO Cable DTE CB ACC 232DTE 30 is 3 0 m long and supports bi directional communication between the serial device and the ControlBridge 5 pin 3 5 mm connector DB9 M connector controlled device Figure 2 4 Serial IO Cable DTE CB ACC 232DTE 30...

Page 12: ...r controlled device Figure 2 5 Serial IO Cable DCE CB ACC 232DTE 30 ControlBridge Control Processor 19 inch Mounting Kit CB CP RMK The ControlBridge Control Processor 19 inch Mounting Kit CB CP RMK is a shelf that supports your ControlBridge Processor 100 or 200 in a 19 inch rack It s made of stainless steel and measures 1 U high 1 75 and 19 wide The shelf weighs 1 3 kg and includes mounting hardw...

Page 13: ...n 3 1 Shelf Placement or Stacking Four rubber feet are provided for shelf placement or stacking Stick the rubber feet near the corner edges on the bottom side of the controllers see picture below Rubber feet Figure 3 1 Installing rubber feet on the ControlBridge Processor ...

Page 14: ...side of the controller see picture below The M3 x 6 screws are included with the Rackmounting Shelf Don t use longer screws this might damage PCBs inside the unit If you install only one controller use the cover panel delivered with the shelf Screw holes 12 123 41 2 123 4 SERIAL IR SERIAL GENERAL I O RELAY IR SENSOR P W R L I N K C P U 12 1234 12 123 4 SERIAL IR SERIALG ENERAL I O RELAY IR SENSOR ...

Page 15: ...s Press the S D button until the CPU LED indicator flashes to confirm the system defaults settings are restored according to table below System Default column Use a thin screwdriver to press the S D button Table 4 1 Factory and System Default settings Factory Default System Default Configuration Identification Name Empty Not changed IP settings Host name Empty Not changed IP address 192 168 1 127 ...

Page 16: ...nged Primary NTP server Empty Not changed Secondary NTP server Empty Not changed Applications Empty Not changed File storage Empty Not changed System Firmware Current version Not changed Password Empty Empty 4 2 Indicators Table 4 2 General Indicators Indicator Color Off On Flashing POWER Blue No power presented Power is ON The unit is ready LINK Green Network is not detected Network link activity...

Page 17: ...d ON IR SERIAL Yellow No data or IR code transmitted Data or IR code is being transmitted KNX Green Red No data activity Data activity RELAY Red Relay is switched OFF Relay is switched ON SERIAL Green Red No data transmitted or received Data is being transmitted Data is being received VERSATILE Green Yellow Output is switched OFF No data or IR code transmitted Output is switched ON Data or IR code...

Page 18: ...d the capture unit as described below IR remoter 1 2 1 2 3 4 1 2 1 2 3 4 SERIAL IR SERIAL GENERAL I O RELAY IR SENSOR P W R L I N K C P U Figure 4 1 IR remote configuration Be sure to set the proper distance between the capturing unit and the remote unit to accommdate the the capturing unit s requirements Start ControlBridge Builder and go to the appropriate driver and command Set the IP address o...

Page 19: ...ut using an external IR receiver e Fn 0 En te r 7 8 9 4 5 6 1 2 3 Ex it Vo lum e Ch an ne l Me nu Re c Pa us e ON 17 6 5 4 3 28 Controller The IR Adapter connects to the rest of the control system via IR communication As the IR receiver you can use The remote control unit IR receiver built into ControlBridge controllers IR receiver built into 8 Button Laminated Keypad and 8 Button Engraved Keypad ...

Page 20: ... adapter supplied in the product package Using another power supply may damage the unit Power consumption ControlBridge 100 max 4 W ControlBridge 200 max 4 W Table 5 2 Connector Pin Out PWR IN 2 pin 3 5 mm Pin Description G Power 24 VDC G Ground Power Adapter A standard power adapter is delivered with the ContrBridge Attach the 2 pin connector of the power supply unit to the PWR IN connector locat...

Page 21: ...igure 5 2 Ethernet connection with PoE infrastructure 5 3 ControlBridge Network The ControlBridge links to a 10 100 BASE T LAN via its RJ 45 connector The length of the Ethernet cable connecting controller to the network must not exceed 100 meters Table 5 3 Connector pinout RJ 45 Pin Signal CAT5 Cable Color 1 TX_D1 and PoE White Orange 2 TX_D1 and PoE Orange 3 RX_D2 and PoE White Green 4 Blue 5 Wh...

Page 22: ... IN RELAY GENERAL I O SERIAL IR SERIAL AUDIO LINE ControlBridge Network default IP address 192 168 1 127 IN OUT 1 2 3 4 1 2 1 2 3 4 G 1 2 24 VDC F D Figure 5 3 Direct PC connection LAN Network Connection Attach one end of an RJ 45 Ethernet straight through cable to the ControlBridge Network port and attach the other end of the RJ 45 Ethernet cable to your computer Ethernet cable straight through L...

Page 23: ...7 2 Click Start 3 Enter ncpa cpl into the Search Box and press Enter The following window is displayed Figure 5 5 Windows 7 screen 1 3 Right click on network adapter used for connection with controller and then right click and select Properties 4 Select Internet Protocol TCP IP and click Properties button Figure 5 6 Windows 7 screen 2 ...

Page 24: ...se the option to switch to Classic View 3 Double click Network Connections Figure 5 7 Windows XP screen 1 1 Select Use the following IP address option Set IP address to 192 168 1 1 or other address different from 192 168 1 127 and from 192 168 1 128 and Subnet mask to 255 255 255 0 Leave other options unchanged and click OK Figure 5 8 Windows XP screen 2 ...

Page 25: ...all channels is RS 232 you must set other modes in the programming application For more details see your programming manuals RS 232 Mode Output signal levels for RS 232 are in the 10 V to 10 V range This is the default mode for all channels Table 5 5 RS 232 pinout SERIAL RS 232 3 pin 3 5 mm Pin Signal Description Direction 1 2 3 1 TxD RS 232 Transmitted Data From controller 2 RxD RS 232 Received D...

Page 26: ...smitted Data From controller 2 RTS RS 232 Request to Send From controller 3 GND Ground 4 RxD RS 232 Received Data To controller 5 CTS RS 232 Clear to Send To controller RS 422 Mode You must set this mode in the programming application Table 5 8 RS 422 pinout SERIAL RS 422 5 pin 3 5 mm Pin Signal Description Direction 1 2 3 4 5 1 Tx A RS 422 Transmit Data Idles High From controller 2 Tx B RS 422 Tr...

Page 27: ...ied Resistance input Range 2 kohms 20 kohms 200 kohms auto Resolution 12 bit Adjustable digital filter Accuracy digital filter applied 100 ohms to 800 ohms 3 of reading 0 1 of range 800 ohms to 20 kohms 0 3 of reading 0 1 of range 20 kohms to 200 kohms 1 of reading 0 1 of range Output modes Digital output Max sink current 200 mA max 30 VDC Catch diodes for use with real load Current pullup Current...

Page 28: ...le threshold High sensitivity binary 0 1 45 V binary 1 2 05 V Low sensitivity binary 0 5 8 V binary 1 8 2 V Input impedance 100 kohms Adjustable digital filter The port offers adjustable threshold as described in the following picture High sensitivity binary 0 1 45 V binary 1 2 05 V Low sensitivity binary 0 5 8 V binary 1 8 2 V 1 45 2 05 binary 0 binary 1 binary 0 5 10 Input V 5 8 8 2 binary 0 bin...

Page 29: ...ater flow meters etc For an electric meter a pulse output corresponds to a certain amount of energy passing through the meter kWhr Whr For single phase domestic electric meters each pulse usually corresponds to 1 Whr 1000 pulses per kWhr For higher power meters often three phase each pulse corresponds to a greater amount of energy eg 2 Whr per pulse or even 10 Whr per pulse For pulse outputs from ...

Page 30: ...ter 5 Connecting The following table describes how to use voltage input Table 5 14 Voltage input Detecting a voltage S G Max 10 VDC Sensors with voltage output 0 10 VDC Reading voltage S G Max 10 VDC Potentiometer with external power supply ...

Page 31: ...applied 100 ohms to 800 ohms 3 of reading 0 1 of range 800 ohms to 20 kohms 0 3 of reading 0 1 of range 20 kohms to 200 kohms 1 of reading 0 1 of range The following table describes how to use resistance input Table 5 15 Resistance input Reading resistance S G 100 to 200 kohms Potentiometer for light temperature and volume control Temperature sensors S G 100 to 200 kohms Thermistors and temperatur...

Page 32: ...Catch diodes for use with real load The following table describes how to use digital output Table 5 16 Digital output Driving a relay coil S G Max 30 VDC Max 250 mA Driving relays with low voltage coil Driving LED indicator S G Driving LEDs for custom indicators on keyboards control panels etc Driving LED strip S G Max 30 VDC Max 250 mA Driving LED strips with max voltage 30 VDC and max current 20...

Page 33: ...f devices WARNING We do not recommend connecting more infra red emitters from various manufacturers in parallel because the output can be either overloaded or damaged Connecting S G Controlled Device 1 Controlled Device 2 Controlled Device 3 IR Adapter IR Adapter IR Adapter FIgure 5 10 IR output Serial Output This mode provides one way RS 232 output channel Serial output parameters are as follows ...

Page 34: ...32 outputs can be combined on independent outputs for example three outputs can be used as IR and five outputs can be used as RS 232 Table 5 17 IR Serial IR SERIAL 2 pin 3 5 mm Pin Signal Description S G S Signal IR Serial Signal Output G GND Ground NOTES All pins labelled G are connected together Up to three original infra red emitters IR Adapters can be connected to each output in parallel We do...

Page 35: ...is connected in series 0 7 V dropdown Analog input is rated 0 5 VDC Analog to digital A D converter has 10 bits precision i e 1024 levels Digital output can switch max 24 VDC 80 mA Output voltage for output switch on is approx 0 6 V I O schematic diagram value CLOSE OPEN 680 Ohm value ON OFF ON OFF 5 VDC A D Input Output Signal Ground 10 bit INPUT OUTPUT PULLUP Figure 5 12 I O schematic diagram Co...

Page 36: ...hen it is not turned on energized NC C NO NC C NO Relay open Relay closed Figure 5 13 Relay Connector pin out Table 5 19 Relay connnector pinout RELAY 3 pin 3 5 mm Pin Description C NO NC NC Relay Contact Normally Closed C Relay Contact Common NO Relay Contact Normally Open 5 8 Audio Line IN This connector provides unbalanced line level audio Connector pinout Table 5 20 Audio line in connector pin...

Page 37: ...balanced line level audio Connect audio devices such as an audio amplifier or powered speakers to this connector Connector pin out Table 5 21 Audio line out connector pinout AUDIO LINE OUT 3 pin 3 5 mm Pin Signal Description L G R L Left Left channel output G GND Ground R Right Right channel output ...

Page 38: ...e Network chapter 2 Run ControlBridge Builder on your PC 3 Open a project in ControlBridge Builder You must have the appropriate controller properly inserted and configured 4 Use the tool bar Final button to open the Upload and Export Application dialog box 5 Be sure your controller is checked Final Button Upload Button Figure 6 1 ControlBridge Builder screen 6 Use the Upload button to start appli...

Page 39: ...ation Files to export an application and store it in file named cvca 6 Connect the controller to your computer as described in the Connecting ControlBridge Network chapter 7 Run the Internet browser on your PC and type in the same controller IP address that you see in the ControlBridge Builder project Properties IP address window 8 Admin Control Panel is shown 9 Go to the System page and check the...

Page 40: ...Login button to enter the ControlBridge Unit web pages Remember that the password is case sensitive To change your password use the Password menu after you are logged in 7 3 Configuration Identification Figure 7 2 Configuration screen Identification tab Each ControlBridge Unit can be identified by a unique identification name Unique names are most useful in applications requiring more than one Con...

Page 41: ... ControlBridge Builder program written for your specific application For control systems with more than one ControlBridge Units you must give a unique IP address to each ControlBridge Unit Some control systems are standalone and not part of a larger network For such standalone systems the Host name is optional However for control systems that are connected to a larger network obtain the Host name ...

Page 42: ...gure 7 5 Current Date and Time screen Use this page to set the time clock on your ControlBridge Unit The current date time and time zone are shown on the Current time line The applicable boxes can be selected to enter changes to the date day month year time hour minute second Be sure to click the Apply button for any changes to become effective Time Zone Figure 7 6 Time Zone ...

Page 43: ...nges to become effective Internet Clock Figure 7 7 Internet Clock screen Use this page to synchronize the ControlBridge Unit s date and time with an internet clock Begin by selecting the check box for Use Internet clock Next enter the IP addresses or complete address name of the primary and secondary NTP servers in the Primary NTP server and Secondary NTP server boxes Be sure to click the Apply bu...

Page 44: ...nit to a personal computer by clicking the File name Files are easily deleted with the Delete button The Total stop button stops a running application This application will not automatically start after reset 7 6 File Storage Figure 7 9 File storage screen You can use the ControlBridge Unit s generous memory pool for an auxiliary file storage This is helpful for storing presets in archiving electr...

Page 45: ...resses of your ControlBridge Unit The sender Name and E mail are used by the XPL2 commands EmailSend and PresetEmailSend The recipient Names and E mails are addresses of recipients where e mails will be sent using the XPL2 command PresetEmailSend 7 8 System Firmware Figure 7 11 Firmware screen Use this page to update the ControlBridge Unit firmware The Current version of firmware is shown To uploa...

Page 46: ... Data Area Figure 7 12 Format Data Area tab To completely clear all data and restore the factory default settings click the Format data area button This will remove all data including Applications and File storage files Configuration will be cleared including IP address and password IP address will be restored to the default 192 168 1 127 7 9 Password Figure 7 13 Password screen ...

Page 47: ... implement the new password 7 10 Backup Figure 7 14 Backup screen Use this page for backup applications files folders and ControlBridge Unit s configuration The Backup copies all Applications Application data File storage and ControlBridge Unit s settings to the one archive This archive is saved to the PC To start the backup process click the Backup button NOTE To see the backed up restored applic...

Page 48: ... Unit s settings can also be restored too check the Restore configuration box The ControlBridge Unit s settings are accessible via the Configuration Date and time and Password menus Important note Actual password and IP settings will be restored too Important note When restoring files the running application will stop and all applications files and folders currently stored in the ControlBridge Uni...

Page 49: ...x com Chapter 7 Admin Control Panel 7 12 Logout Figure 7 17 Logout screen This screen isn t displayed if the password is empty factory default status 7 13 License This page describes the software license Figure 7 18 License screen ...

Page 50: ...877 877 2269 blackbox com Page 50 NOTES ...

Page 51: ...Page 51 877 877 2269 blackbox com NOTES ...

Page 52: ...ve 24 7 Tech support available in 60 seconds or less Copyright 2016 Black Box Corporation All rights reserved Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any third party trademarks appearing in this manual are acknowledged to be the property of their respective owners Black Box Tech Support FREE Live 24 7 Tech support the way it should be Great tech suppo...

Reviews: