Page 52
877-877-2269 | BlackBox.com
Appendix: RS-232 Command Set
A.2 Commands
IDX
Function
Command
Response
Parameters Desription
Example
1
Switch input for output
SET SW in out[CR/
LF]
SW in out[CR/LF]
in = {hdmi1,hdmi2,hdmi3,dp,vg
a1,vga2,hdbt1,hdbt2};
out = {out1,out2};
Command: SET SW hdmi1 out1[CR/LF]
Response: SW hdmi1 out1[CR/LF]
2
Get which input map-
ping to the indicate out-
put
GET MP out[CR/LF]
MP in out[CR/LF]
in= {hdmi1,hdmi2,hdmi3,dp,vg
a1,vga2,hdbt1,hdbt2};
out = {out1,out2};
Command: GET MP out1[CR/LF]
Response: MP hdmi1 out1[CR/LF]
3
Get which output map-
ping to all input
GET MP all[CR/LF]
MP in out[CR/LF]
MP in out[CR/LF]
in = {hdmi1,hdmi2,hdmi3,dp,vg
a1,vga2,hdbt1,hdbt2};
out = {out1,out2};
all = {all};
Command: GET MP all [CR/LF]
Response: MP hdmi1 out1[CR/LF]
MP hdmi2 out2[CR/LF]
4
Set CEC POWER ON/
OFF
SET CECPWR_
ONOFF out prm[CR/
LF]
CECPWR_ONOFF
out prm[CR/LF
prm = {on,off}
out = {out1,out2};
Command: SET CECPWR_ONOFF out1
on[CR/LF]Response: CECPWR_ONOFF
out1 on[CR/LF]
5
Get CEC POWER ON/
OFF Status
GET CECPWR_
ONOFF out [CR/LF]
CECPWR_ONOFF
out prm[CR/LF]
prm = {on,off}
out = {out1,out2};
Command: GET CECPWR_ONOFF
out1[CR/LF]Response: CECPWR_ONOFF
out1 on[CR/LF]
6
Set CEC POWER Delay
Time
(This command is valid
when there is no active
signal input)
SET CECPWR_
DELAY out prm[CR/
LF]
CECPWR_DELAY
out prm[CR/LF
out = {out1,out2};
prm = {0,1,2,3…,off}// according
to the actual time counter, 0
means 0 means, 1 means 1 min-
ute , 2 means 2 minutes and so
on, it is 2 minutes by default, the
Max wait time is 30 minutes;
off means when no active signal,
the unit will not auto power off.
Command: SET CECPWR_DELAY out1
3[CR/LF]Response: CECPWR_DELAY out1
3[CR/LF]
7
Get CEC POWER Delay
Time
GET CECPWR_
DELAY out [CR/LF]
GECPWR_DELAY
out prm[CR/LF]
out = {out1,out2};
prm = {0, 1,2,3…,off}// accord-
ing to the actual time counter,1
means 1 minute ,2 means 2 min-
utes and so on, it is 2 minutes by
default, the Max wait time is 30
minutes;
off means when no active signal,
the unit will not auto power off.
Command: GET CECPWR_DELAY out1
[CR/LF]Response: GECPWR_DELAY out1
3[CR/LF]
8
Set Audio Extraction
on/off
SET AUDIOEXTRACT
prm[CR/LF]
AUDIOEXTRACT
prm[CR/LF]
prm = {on,off}
The Audio Extraction is on by
default.
Command: SET AUDIOEXTRACT on[CR/
LF] Response: AUDIOEXTRACT on[CR/LF]
9
Get Audio
Extraction
status
GET
AUDIOEXTRACT
[CR/LF]
AUDIOEXTRACT
prm[CR/LF]
prm = {on,off}
The Audio Extraction is on
by default.
Command: GET
AUDIOEXTRACT[CR/LF] Response:
AUDIOEXTRACT on[CR/LF]
10
Get Phantom Power
status
GET MICPWR[CR/
LF]
MICPWR
prm[CR/LF]
prm = {on,off}
Command: GET MICPWR[CR/LF]
Response: MICPWR on [CR/LF]
11
Adjust Volume Gain
SET VOLGAIN_
DATA aout
prm[CR/LF]
VOLGAIN_DATA
aout prm[CR/LF]
aout = {audioout};
prm = {0~100}
Command: SET VOLGAIN_DATA
audioout 50[CR/LF]
Response: VOLGAIN_DATA audio-
out 50[CR/LF]
Summary of Contents for AVSC-0802H
Page 18: ...Page 18 877 877 2269 BlackBox com Chapter 2 Overview Figure 2 4 Classroom example...
Page 36: ...Page 36 877 877 2269 BlackBox com Chapter 5 Web UI Figure 5 17 Administrator Setting screen...
Page 57: ...Page 57 877 877 2269 BlackBox com NOTES...
Page 58: ...Page 58 877 877 2269 BlackBox com NOTES...