Page 212
724-746-5500 | blackbox.com
Chapter 6: Serial Control
Table 6-12. Connection of CPU (input) with CON (output).
Bytes
Description
Coding
1
Control character
0x1B
1
Server identification
0x5B
1
Command
0x48
2
Total length of telegram (9 bytes, binary)
0x09 0x00
2
Requested console
0x01 0x00 (for Console 1) to 0x11F 0x00 (for
Console 287)
2
Requested CPU
0x01 0x00 (for CPU 1) to 0x11F 0x00 (for
CPU 287)
Example:
Connection of CPU 43 with Console 23
0x1B 0x5B 0x48 0x09 0x00 0x17 0x00 0x2B 0x00
Table 6-13. Request of CPU (input) for CON (output)
with a fixed console number.
Bytes
Description
Coding
1
Control character
0x1B
1
Server identification
0x5B
1
Command
0x49
2
Total length of telegram (9 bytes, binary)
0x09 0x00
2
Total number of consoles (binary, 1…max.
CONs)
0x01 0x00 (for Console 1) to 0x11F 0x00 (for
287 Consoles)
2
Requested consoles
0x01 0x00 (for Console 1) to 0x11F 0x00 (for
Console 287)
Example:
Request of CPU (input) for Console 23 with 50 consoles in total
0x1B 0x5B 0x49 0x09 0x00 0x32 0x00 0x17 0x00