background image

BLA

CK

BOX

SRX

TO

 LO

CA

L

LIN

K

PO

WE

R

SH

AR

PN

ESS

B

A

A

B

ON

REM

OTE

®

724

-74

6-5

500

®

BLA

CK

BOX

SRX

TO

 RE

MO

TE

LIN

K

PO

WE

R

ON

LOCAL

®

724

-74

6-5

500

®

IN

OU

T

IN

OU

T

ServSwitch

 SRX

USER GUIDE

contents

®

NETWORK SERVICES

®

Order 

toll-free 

in the U.S.: Call 

877-877-BBOX 

(outside U.S. call 

724-746-5500

)

FREE technical support 24 hours a day, 7 days a week: Call 

724-746-5500 

or fax 

724-746-0746

Mailing address: 

Black Box Corporation

, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: 

www.blackbox.com 

• E-mail: 

[email protected]

CUSTOMER

SUPPORT

INFORMATION

FEBRUARY 2009

ACU5051A
ACU5052A

Summary of Contents for ACU5051A

Page 1: ...DE NETWORK SERVICES Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address...

Page 2: ...at the remote module 8 Dual user configuration 10 Video display DDC information 11 Video sharpness adjustment 12 Operation General use 13 Dual user arbitration 13 Peripheral operation 13 Further info...

Page 3: ...est interludes The USB connections are seamless and thanks to our unique Bi tripos circuitry four full speed USB 2 0 devices can be used simultaneously with full support for disconnect re connect at a...

Page 4: ...module BL AC K BO X SRX TO LO CAL LINK PO W ER SH ARP NES S B A A B ON REMOTE 724 746 5500 SRX Dual VGA remote module USB A to B type lead Audio lead 3 5mm jacks Video lead 15 way male to male RS232...

Page 5: ...welcome contents installation operation Optional items Power adapter and country specific power lead for local module if USB powering not possible Rack mount chassis...

Page 6: ...lug the SRX local module into another USB hub To do so will reduce the maximum cable length over which the system will extend USB also some USB hubs may not provide enough power to operate the local u...

Page 7: ...h the video USB see the Important note on page 5 and optionally audio connections from the computer system to the relevant sockets on the local module Dual VGA variant only Optionally attach a second...

Page 8: ...ule and attach the other end to a vacant serial port on your computer 5 Attach the connector of the category 5 5e or 6 link cable up to 50 metres in length to the TO REMOTE socket on the local module...

Page 9: ...Dual VGA variant only Optionally attach the lead from a second video monitor to the upper video out socket on the remote module To secondary video monitor BLACK BOX REMOTE A B REMOTE To USB devices e...

Page 10: ...H A R P N E S S O N 5 5 0 0 S R X T O L O C A L L IN K P O W E R S H A R P N E S S B A O N Dual VGA variant only Attach the connector of a second category 5 5e or 6 link cable up to 50 metres in lengt...

Page 11: ...IDEO USB USER 1 USER 2 BLACK BOX SRX TO REMOTE LINK POWER ON LOCAL 724 746 5500 IN OUT IN OUT BLACK BOX SRX TO REMOTE LINK POWER ON LOCAL 724 746 5500 IN OUT IN OUT BLACK BOX SRX TO LOCAL LINK POWER S...

Page 12: ...local module is powered up it will read and store the DDC information from your monitor You can then return the monitor to its remote position and the new DDC information will be used at every power...

Page 13: ...ntrast image The best way to clearly view the effect of sharpness and brightness adjustments is to display a high contrast image with vertical edges on the screen Open a word processor type the capita...

Page 14: ...en the local module has feed through peripherals attached to it adjacent to the computer For this reason the SRX dual user arrangement is better suited to situations where two users would not often re...

Page 15: ...cksum error prior to copying no information will be programmed Three yellow flashes Too much data to fit into the module the module can hold a maximum of two pages of DDC information Rapid yellow flas...

Page 16: ...e power adapter into a socket outlet close to the module that it is powering Replace the power adapter with a manufacturer approved type only Do not use the power adapter if the power adapter case bec...

Page 17: ...ease the separation between the equipment and the receiver c Connect the equipment to an outlet on a circuit different from that to which the receiver is connected d Consult the supplier or an experie...

Page 18: ...que impidan el flujo de aire por los orificios de ventilaci n 10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufas u otros aparatos...

Page 19: ...n further information 18 www ctxd com Documentation by 2009 Black Box Corporation All trademarks are acknowledged Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 United States of America...

Page 20: ...x fr 33 1 45 606 717 33 1 45 606 747 tech blackbox fr Germany www black box de 49 811 5541 110 49 811 5541 499 techsupp black box de Italy www blackbox it 39 02 27 404 700 39 02 27 400 219 supporto te...

Reviews: