background image

 

WARNING: 

To reduce the risk of injury, user must read and understand instruction

manual.

SAVE THESE INSTRUCTIONS

Safety Instructions

• Do not operate the stud sensor in explosive atmospheres, such as in the presence of

flammable liquids, gases, or dust. 

• Use the stud sensor only with 9 volt alkaline battery. Use of any other batteries may create a

risk of fire.

CAUTION: Material thickness, type of material, moisture content, and other variables can

effect sensing results. The sensor may detect electric wiring or pipes in the same manner

that studs are detected depending on their location to the wall surface. Use caution when

drilling, nailing or cutting into walls, floors and ceilings which may contain electrical wiring or

pipes. These items may be detected by the sensor in the same manner in which studs are

detected. Because studs are normally spaced 16 inches (406 mm) or 24 inches (610 mm)

apart and are usually 1-1/2 inches (38 mm) wide, beware of anything closer together or of

a different width. 

Always turn off the power when working near electrical wires.

VEA EL ESPAÑOL EN LA CONTRAPORTADA.

SAVE THIS MANUAL FOR FUTURE REFERENCE.

INSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA.

ADVERTENCIA: LÉASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. 

INSTRUCTION

MANUAL

B

B

B

B

D

D

D

D

LL

LL

11

11

55

55

22

22

S

S

S

S

  

  

S

S

S

S

tt

tt

uu

uu

d

d

d

d

  

  

--

--

M

M

M

M

ee

ee

tt

tt

aa

aa

ll

ll

  

  

S

S

S

S

ee

ee

nn

nn

ss

ss

o

o

o

o

rr

rr

  

  

&

&

&

&

  

  

B

B

B

B

D

D

D

D

LL

LL

11

11

55

55

33

33

S

S

S

S

  

  

S

S

S

S

tt

tt

uu

uu

d

d

d

d

  

  

--

--

M

M

M

M

ee

ee

tt

tt

aa

aa

ll

ll

  

  

--

--

  

  

W

W

W

W

ii

ii

rr

rr

ee

ee

  

  

S

S

S

S

ee

ee

nn

nn

ss

ss

o

o

o

o

rr

rr

Cat Nos. BDL152S, BDL153S Form # 585441-00 (JUN-03-2) Copyright © 2003 Black & Decker  
Printed in China

 

FEATURES

A.) Green LED (

Light

Emitting Diode)

B.) Red LEDs (4)

C.) AC Detected LED

D.) Stud Mode LED

E.) Metal Mode LED

F.) Wire Mode LED

G.) On/Off Button

H.) Battery Compartment

Cover

2

B

G

A

Operating Instructions

INSTALLING THE BATTERY

Remove the battery compartment cover (H) by pressing in the tab in the center of the cover

and pulling back. Insert a fresh 9 volt alkaline battery into compartment and connect to battery

cable. Replace the battery compartment cover and snap shut. 

CALIBRATION AND SCANNING
CALIBRATION

1.) For stud sensing, move slide switch to STUD position. Hold unit straight up and down and

place flat against wall as shown in Figure 2. For METAL sensing, move slide switch to  METAL

position and calibrate by holding unit in air away from metal objects. For WIRE sensing, move

slide switch to AC WIRE position and calibrate by holding unit in air away from a “live”

unshielded electrical wire.

2.) Press in and hold the sensor ON/OFF button (G) while calibrating and continue holding in

button while scanning. 

a.) The upper GREEN LED (A) will light, 

b.) The unit will beep once while it is calibrating,

c.) The bottom RED LED will light. 

SCANNING

STUD MODE FIGURE 2A

For stud sensing up to 3/4 in. (19mm) deep.

1.) After calibration, while still holding in button, slide sensor slowly, (Figure 2) horizontally

across surface of wall without lifting or tilting. 

2.) The upper GREEN LED will light and a beeper will sound when an edge is detected, mark

that spot as shown in Figure 3.

Repeat this cycle coming from the other direction to confirm the mark.

METAL MODE FIGURE 2B

For metal (iron, etc.) sensing up to 2 inches (51mm) deep. For metal (copper, etc.) sensing up

to 1 inch (25mm) deep.

1.) After calibration, while still holding in button, slide sensor slowly across surface without

lifting or tilting.

2.) The upper GREEN LED will light and a beeper will sound when you are close to a metal

object, mark that spot. Reverse directions to locate other edge of target and mark spot. The

center of the two marks will be the center of the target object.

AC WIRE MODE FIGURE 2C (BDL153S ONLY)

For wire sensing up to 2 in. (51mm) deep.

1.) After calibration, while still holding in button, slide sensor slowly across surface without

lifting or tilting.

2.) The upper GREEN LED will light and a beeper will sound when you are close to a “live”

wire, mark that spot. Reverse directions to locate other edge of target and mark spot. The

center of the two marks will be the center of the target object.

The sensor detects from 90 to 250 V at 50 to 60 Hz AC in a “live” unshielded electrical wire. 

WARNING: 

Always turn off the power when working near electrical wires, electric

shock may result.  

Occasionally, pipes and electrical wiring may not be detected by this product. Observe

caution when cutting or drilling into areas that may contain concealed pipes or wiring. Always

turn off power when working near electrical wires. The sensor will not detect hot wires inside

metal pipe or metal conduit, behind metallic wall covering, or behind some plywood or other

dense materials. 

AC DETECTION MODE 

The sensor detects AC voltage in all settings. It assists in identifying when the sensor is near

AC wiring. Use the AC switch mode to fine tune the location of the wiring. Static charge may

spread detection 12 in. (30.4cm) on both sides of wire. 

WARNING: 

Always turn off the power when working near electrical wires, electric

shock may result.  

Occasionally, pipes and electrical wiring may not be detected by this product. Observe

caution when cutting or drilling into areas that may contain concealed pipes or wiring. Always

turn off power when working near electrical wires. The sensor will not detect hot wires inside

metal pipe or metal conduit, behind metallic wall covering, or behind some plywood or other

dense materials. 

TIPS FOR OPTIMUM USE

• Test batteries before each use. Press and hold the on/off switch until the RED LED remains

on. Then move your free hand toward the back of the unit. The GREEN LED should illuminate

and then go out as you move your hand away from the unit. Replace the batteries if the

GREEN LED does not illuminate.

• Hold stud sensor straight up and down.

• Because studs are normally spaced 16 inches or 24 inches apart and are 1-1/2 inches wide,

beware of anything closer together or of a different width. Doors and windows are

constructed with studs and headers which are closer together.

Avoid materials which have inconsistent density such as:

• Carpeting and padding

• Ceramic floor tile

• Wallpaper containing metallic foils or fibers. Generally, surfaces covered with regular

wallpaper or fabric will scan with no difference in function.

• Walls that are freshly painted and are still damp.

• Excessively thick plaster and lath. 

Maintenance

Use only mild soap and damp cloth to clean the tool. Never let any liquid get inside the tool;

never immerse any part of the tool into a liquid.

Cat. No.BDL152S 

BEFORE RETURNING THIS PRODUCT 

FOR ANY REASON PLEASE CALL 

1-800-544-6986

IF YOU SHOULD HAVE A QUESTION OR EXPERIENCE A

PROBLEM WITH YOUR BLACK & DECKER PRODUCT,

CALL 1-800-544-6986

BEFORE YOU CALL, HAVE THE FOLLOWING INFORMATION AVAILABLE, CATALOG No., TYPE No., AND

DATE CODE (e.g. 20000130M). IN MOST CASES, A

BLACK & DECKER 

REPRESENTATIVE CAN

RESOLVE YOUR PROBLEM OVER THE PHONE. IF YOU HAVE A SUGGESTION OR COMMENT, GIVE

US A CALL. YOUR FEEDBACK IS VITAL TO BLACK & DECKER.

 

 

WIRE

 

WIRE

C

D

E

B

A

C

E

F

G

D

 

 

 

2A

2B

2C

1

LED brightens to

signal edge of stud...

2

*Recess edge 

indicates 

approximate

center of stud...

3

User can mark

the location for 

nailing, securing,

etc...

3

User can mark

the location for 

nailing, securing,

etc...

2

*Recess edge 

indicates 

approximate

center of stud...

3

H

Cat. No.BDL153S 

Cat. No.BDL152S 

Cat. No.BDL153S 

*Based on stud 1-1/2 inches wide

Summary of Contents for BDL153S

Page 1: ... spot Reverse directions to locate other edge of target and mark spot The center of the two marks will be the center of the target object AC WIRE MODE FIGURE 2C BDL153S ONLY For wire sensing up to 2 in 51mm deep 1 After calibration while still holding in button slide sensor slowly across surface without lifting or tilting 2 The upper GREEN LED will light and a beeper will sound when you are close ...

Page 2: ...Reprendre le mouvement en sens inverse pour confirmer la marque MODE MÉTAL FIGURE 2B Mode servant à détecter les objets en métal situés à une profondeur allant jusqu à 51 mm 2 po dans le cas du fer etc ou jusqu à 25 mm 1 po dans le cas du cuivre etc 1 Après l étalonnage le bouton est toujours enfoncé faire glisser lentement l outil contre la surface sans le soulever ni l incliner 2 Le témoin à DEL...

Page 3: ...résence de contreplaqué de renforts en bois épais placés derrière une cloison ou un mur plus épais que d habitude Remarque l espace entre chaque montant varie généralement entre 406 et 610 mm 16 et 24 po et ceux ci mesurent près de 38 mm 1 1 2 po de largeur Lorsque la prise fonctionne au moyen d un interrupteur s assurer que ce dernier est en position de marche Sinon l outil ne fonctionnera pas Bi...

Page 4: ... recomendado para ser utilizado con esta herramienta podría ser peligroso ADVERTENCIA DE LA FCC Este dispositivo cumple con la sección 15 de las Normas FCC Su operación está sujeta a las siguientes dos condiciones 1 Este dispositivo no puede causar interferencia dañina y 2 este dispositivo debe aceptar cualquier interferencia que reciba incluyendo aquella interferencia que pudiera causar una opera...

Reviews: