Gas Pressure Fryer
Maintenance
29
Troubleshooting
Refer to the table below for troubleshooting information.
Problem
Cause
Possible Solution
Shortening Heating Too Slowly
Low voltage or improper
voltage
Contact an authorized BKI service agent
for corrective action.
Bad thermostat or loose
wires
Contact an authorized BKI service agent
for corrective action.
Weak heating elements or
heating elements breaking
down
Contact an authorized BKI service agent
for corrective action.
Coil on contactor is bad
Contact an authorized BKI service agent
for corrective action.
Breading build-up on
heating elements
Clean heating elements. If problems
persist, contact an authorized BKI service
agent for corrective action.
Filter System Not Working
Uncertain
Press the reset button on end of pump
and hi-limit reset button under control
panel. If problems persist, contact an
authorized BKI service agent for
corrective action.
Connections not tight
Tighten the connections. If problems
persist, contact an authorized BKI service
agent for corrective action.
Filter valve not open
Contact an authorized BKI service agent
for corrective action.
Filter paper on screen
clogged with crumbs
Change filter paper. If problems persist,
contact an authorized BKI service agent
for corrective action.
Motor hums, but does not
pump
Check for clogged pump. If problems
persist, contact an authorized BKI service
agent for corrective action.
Motor and pump coupling
worn
Contact an authorized BKI service agent
for corrective action.
No power to control panel
Make sure drain valve is completely
closed. If problems persist, contact an
authorized BKI service agent for
corrective action.
Computer Hangs
Computer malfunction.
Press and hold the Toggle/Clear button
while moving the FRY/OFF/FILTER
switch from FRY to OFF and back to
FRY. If problems persist, contact an
authorized BKI service agent for
corrective action.