Gas Pressure Fryer
Operation
21
Table 2.
Product Programming Procedure
STEP
ACTION
DISPLAY
COMMENTS
1
Press the
FILTER/OFF/FRY
switch to
FRY
.
LOW
2
Press PROG on the keypad.
PROGRAM CODE
3
Input 1724 and press ENTER.
PROGRAM
PRODUCT #
4
Select the program product number (1-8).
PROGRAM
PRODUCT X
X refers to the program number
you selected.
5
Press ENTER.
PROGRAM TIME1
00:00
This command allows you to
specify the cooking time for this
stage. The time displayed may be
a previously programmed value.
6
Press TOGGLE/CLEAR and input the
number of minutes you want to cook.
PROGRAM TIME1
XX:XX
XX:XX refers to the number of
minutes you input.
7
Press ENTER.
PROGRAM TEMP1
000
°
F
This command allows you to
specify the cooking temperature
for this stage. The temperature
displayed may be a previously
programmed temperature. The
temperature scale may also
display
°
C depending on the
system option that is set.
8
Press TOGGLE/CLEAR and input the
cooking temperature for product to be
cooked.
PROGRAM TEMP1
XXX
°
F
XXX refers to the cooking
temperature you input.
9
Press ENTER.
PROGRAM
TEMPCOM1
FLEX TIME
This command enables you to
select whether or not time is
allowed for the fryer to recover
from temperature loss while
cooking during this stage. The
FLEX TIME option will allow the
fryer to recover from temperature
loss.
10
Press TOGGLE/CLEAR until the desired
option is displayed.
PROGRAM
TEMPCOM1
X
X refers to the temperature
compensation option selected.
11
Press ENTER.
PROGRAM VALVE1
CLOSED
This command allows you to
specify whether the solenoid
valve will be open or closed
during this stage.
12
Press TOGGLE/CLEAR until the desired
option is displayed.
PROGRAM VALVE1
X
X refers to the solenoid valve
option selected. OPEN is used for
Models
ALF
and
BLF Automatic
Lift
fryers. If your program
requires the solenoid valve to be
closed while cooking, choose the
CLOSED option.