background image

 

Heated Display Merchandisers

 

MODELS WDCG, SSWG, CSWG 
Installation & Operation Manual 

    

 
 
 
 
 

 

 
 
 
 
 

 

Summary of Contents for 220 Recumbent Bike 2010 model

Page 1: ...Heated Display Merchandisers MODELS WDCG SSWG CSWG Installation Operation Manual ...

Page 2: ...st of reinstalling the replacement or repaired part IN NO EVENT SHALL THE COMPANY BE LIABLE FOR LOSS OF USE LOSS OF REVENUE OR LOSS OF PRODUCT OR PROFIT OR FOR INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO FOOD SPOILAGE OR PRODUCT LOSS WARRANTY DOES NOT COVER GLASS BREAKAGE THE ABOVE WARRANTY IS EXCLUSIVE AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARE EXCLUDED INCLUDING THE IMPLI...

Page 3: ... Controls Viewing Settings 6 Software Controls Programming the Controller 7 Preheating 8 Temperature Adjustment 8 Operational Guidelines 8 Unit Shutdown 8 Installation 9 Unpacking and Handling 9 Floor Model 9 Leveling 9 Kick Plate Mounting 10 End Panel Mounting 11 Pedestal Model 12 Leveling 12 Front and Rear Cover Attachment 13 End Panel Mounting 13 Counter Model 14 Wiring 14 Case Joining Trim 15 ...

Page 4: ...ys follow recommended safety precautions listed in this manual Below is the safety alert symbol When you see this symbol on your equipment be alert to the potential for personal injury or property damage Safety Signs and Messages The following Safety signs and messages are placed in this manual to provide instructions and identify specific areas where potential hazards exist and special precaution...

Page 5: ...onnection and is marked with this symbol Safe Work Practices Beware of High Voltage This equipment uses high voltage Serious injury can occur if you or any untrained or unauthorized person installs services or repairs this equipment Always Use an Authorized Service agent to Service Your Equipment Keep this manual with the Equipment This manual is an important part of your equipment Always keep it ...

Page 6: ...it and a fire extinguisher near the equipment You must use a 40 pound Type BC fire extinguisher and keep it within 25 feet of your equipment Keep emergency numbers for doctors ambulance services hospitals and the fire department near your telephone Know your responsibilities as an Employer Make certain your employees know how to operate the equipment Make certain your employees are aware of the sa...

Page 7: ...wer OFF to the entire unit 2 Power ON Switch Depressing the switch turns power ON to the entire unit When the unit is ON the touchscreen controller is powered the lights illuminate 3 Main Power Isolator This light illuminates to indicate that power is being applied Light to the unit from the main power isolator circuit breaker 4 Analog Touchscreen Used for the operation of the unit and to measure ...

Page 8: ...tings for either Well Temp or Upper Heater touch the appropriate button on the Menu Screen The View Setting Screen for the selected heaters will be displayed To return to the Default Screen touch the Exit Button X If the controller is configured to control each well position independently the View Setting Screen as shown at right will be displayed Use the left and right arrows to display the heate...

Page 9: ...g is being displayed The current heater setting is displayed on the right side of the screen Use the up and down arrows to edit the heater setting The setting is a numeric value between 1 and 10 where 10 is the hottest setting If the controller is configured to control all of the well positions at the same setting the progress bar will be solid and the left and right arrows will not be displayed U...

Page 10: ...ngs in order to maintain the proper internal temperature for the product on display The optional built in product temperature probe or a portable meat thermometer should be used to read the internal temperature of each product The programmed settings should be set to the lowest possible number that will maintain the proper product temperature Operational Guidelines Keep the optional built in produ...

Page 11: ...s are not structurally designed to support excessive external loading such as the weight of a person Do not place heavy objects on the deli cases Move the deli case as close as possible to its permanent location before moving the case off of the shipping pallet Make certain there are no separately packed accessories before discarding packaging During shipment the lubricant in the gas springs may h...

Page 12: ...together 8 Complete the line up by slipping the Counter Top Joint Cover over the end flanges of the adjoining counter tops Kick Plate Mounting A black vinyl covered kick plate is provided for the front and back of each case 1 Slide the front kick plate the wider of the two behind the lower finished front panel of the case see Figure 2 2 Make certain that the ends of the kick plate are flush with t...

Page 13: ...lastic bushings provided over the shoulder screws before inserting the screw into the glass panel Be careful that the screws do not bind in the holes in the glass panel NOTE If the ends are already attached to the case the End Kick Plates can be lowered to the floor To do this loosen the End Trim Panel nuts from inside the case then slide the Kick Plates flush with the floor and tighten the Trim P...

Page 14: ...TO BOTTOM FLANGE OF CASE FRAME LOWER RAISE LEG LEVELER LEVEL CASE Figure 3 Pedestal Model Leveling and Cover Attachment Leveling Deli cases must be installed level to insure proper operation and alignment to adjoining equipment Use a carpenter s level as shown in Figure 3 Begin lineup leveling from the highest point of the store floor 1 Level the case using the leg levelers at the corners of the p...

Page 15: ...Drill two 5 32 diameter holes in each side of the Pedestal Frame to match the predrilled holes in the covers 3 Secure the covers to the frame using the 8 sheet metal screws provided 4 These cases are to be sealed to the floor if required by local health codes Seal the pedestal covers to the floor using a silicone type sealant Dow Corning RTV 732 or equivalent End Panel Mounting Figure 4 Pedestal M...

Page 16: ...specifications an electrical schematic and a parts list Refer to this wiring diagram and the deli case serial number plate for electrical information Field wiring must be sized for the components amperes printed on the serial number plate Actual ampere draw may be less than specified All electrical connections should be in compliance with the NEC and all applicable local codes by a licensed electr...

Page 17: ...re centered on the joint and that they align vertically with each other 4 Drill the case holes 5 32 and attach joint covers with screws provided Before tightening the top screws of the Upper Front Trim slide the Counter Front Trim in place between the screw head and the Upper Front Trim 5 Attach Bumper Ends and Bumper Mounting Base to the front of the cases centered on the vertical surface of the ...

Page 18: ...aning This unit should be cleaned at the end of each day Use the following procedure Failure to remove power from this unit may cause severe electrical shock This unit may have more than one disconnect switch 1 Turn the machine off and allow it to cool down 2 Remove any food pans Using abrasive cleaners may damage the cabinet finish Use only a mild soap and water solution Never steam clean or get ...

Page 19: ...ive Thermostat Contact an authorized BKI service agent for corrective action Loose Wire or bad Connection Contact an authorized BKI service agent for corrective action Holding Temperature Not Adequate Case and food pans have not been preheated Refer to the preheating section on page Error Bookmark not defined If problem persists contact an authorized BKI service agent for corrective action One or ...

Page 20: ...Hot Food Deli Case Wiring Diagrams 18 Wiring Diagrams ...

Page 21: ...Hot Food Deli Case Wiring Diagrams 19 ...

Page 22: ...Hot Food Deli Case Wiring Diagrams 20 ...

Page 23: ...Hot Food Deli Case Wiring Diagrams 21 ...

Page 24: ...Hot Food Deli Case Wiring Diagrams 22 ...

Page 25: ...Hot Food Deli Case Wiring Diagrams 23 ...

Page 26: ...Hot Food Deli Case Wiring Diagrams 24 ...

Page 27: ...Hot Food Deli Case Wiring Diagrams 25 ...

Page 28: ...Hot Food Deli Case Wiring Diagrams 26 ...

Page 29: ...Hot Food Deli Case Wiring Diagrams 27 ...

Page 30: ...Hot Food Deli Case Wiring Diagrams 28 ...

Page 31: ...Hot Food Deli Case Wiring Diagrams 29 ...

Page 32: ...Hot Food Deli Case Wiring Diagrams 30 ...

Page 33: ...Hot Food Deli Case Wiring Diagrams 31 ...

Page 34: ...Hot Food Deli Case Wiring Diagrams 32 ...

Page 35: ...Hot Food Deli Case 33 Notes ...

Page 36: ...P O Box 80400 Simpsonville S C 29680 0400 USA http www bkideas com Made and printed in the U S A LI0117 0607 ...