BK Technologies
- 48 -
Keypad Programming
Conventional Systems and Channels
Much of the information stored in the BKR5000 can be edited using the
keypad. Five separate programming functions can be enabled with the
PC Radio Editor.
Keypad programming selections can only be assigned as a menu item.
Refer to the Keypad Programming section for detailed information on
how to edit programmed radio information.
Minimum Volume [VOL]
Conventional and Trunking Channels
Must be configured as "Customizable" in the PC Radio Editor to access
through the radio. When pressed, changes the volume level at lower
volumes. This allows the user to set their minimum volume to an audible
level.
Monitor [MON]
Conventional Channels
There are three settings available for monitoring traffic on a selected
channel. “Monitor” can be assigned to a button or as a menu item.
Monitor Modes and Indicators
Off
-
Squelch works as configured. (No indicator)
On -
Only carrier squelch is in effect. NAC and CxCSS and
TGID are all ignored. Steady on.
Open
- No squelch is taking place. If there is no signal, the
audio will be static. Solid on.
Button Operation
- A quick press will toggle between Off and On,
while a long press will turn on "Open" mode and short press will return
the radio to Off mode.
Menu Operation
- Open the Monitor menu, select the desired operation
and press “Enter”.
Nuisance Channel Delete [DEL]
Conventional Channels
If enabled, a nuisance channel can be temporarily removed from the
scan list. Nuisance Channel Delete can only be assigned to a button.
To temporarily remove a channel from the scan list, press the assigned
button while the nuisance channel is being received.
To revert to the programmed scan list, turn off Scan, cycle radio power
or select another zone or channel.